Performance characteristics of rapid liquid-phase preparation chromatography system:
PuriFlash ® The rapid preparation chromatography system combines rapid purification (Flash) with preparation liquid chromatography (Prep LC) *;
A high-performance dual head high-pressure pump with a maximum pressure tolerance of 725 psi/50 bar, capable of performing gradient elution from one to four elements;
Suitable for purification from small to large scale, supporting a wider range of rapid separation columns (4.0g-1.6Kg). Increasing the separation load of the column improves productivity and has higher repeatability for larger scale separation.
Smaller fillers can be used for better separation efficiency, higher sensitivity, and improved product purity.
Running faster, improving peak resolution, while also saving time and solvents.
It has solvent detection (mobile phase and waste liquid) and leak detection functions.
Touch screen control, with a simple and user-friendly interface.
Based on Windows XP system, Interchim soft ver.5.0 software features *. The gradient, solvent, flow rate, collection settings, time, and column volume can be automatically switched online.
PuriFlash ® 210 Rapid Liquid Chromatography Preparation -150ml/min @ up to 10 bar
PuriFlash ® 430 Rapid Liquid Chromatography Preparation -200ml/min @ up to 30 bar
PuriFlash ® 450 Rapid Liquid Chromatography Preparation -250ml/min @ up to 50 bar
PuriFlash ® Main parameters of the 450 rapid liquid chromatography system:
1. Pump
Pump type: Parallel double plunger high-pressure pump
Quaternion gradient: four solvent channels
Maximum flow rate: 250ml/min
Maximum pressure: 50bar
Flow accuracy: within ± 1%
2. Detector
UV detection at 200-600nm, continuous scanning with DAD
Flow pool: 0.3mm (1.3,2.4mm) optional
Second set of detection channels: ELSD and other optional options
3. Control module
10.5 'touch screen
Windows XP system
Interchim Software ver 5.0 Operating Software
4 USB ports; RJ45/ RJ11
4. Sample injection system
Injection method: automatic injection, liquid or solid state
Mass injection pump: optional
Automatic six way valve injection: optional
Manual four-way valve injection: optional
5. Column frame
Separation column fixing device
Sample column fixing device
Large size separation column kit standard
6. Fraction collector
4 sample racks
Standard configuration: 176 test tubes (18 × 150mm)
According to the specifications of the test tube, the bracket style can be changed:
(A):13×100mm (B)::16×150mm
(C):18×150mm (D):21×150mm
(E):25×150mm (F):28×150mm
(G):29.5×200mm
The fraction collector supports user customization