● Can be equipped with LCD/LED display header via HART protocol
|

|
●
|
• Can be equipped with LCD/LED display header • Configure using PDA or PC via HART protocol USB direct communication configuration There are more types of thermal resistance inputs, up to 11, with a resistance of up to 10K Ω and a voltage of -100~2000mV Thermocouple input types cover a wide range High precision, built-in cold end compensation • Electrical isolation 2KV
|
|
Output signal: Analog 4-20mA Supply voltage: U=7.5V~45V Load: Max. (V power supply -7.5V)/0.0208A (current output) Alarm current: Below the measurement upper limit, the output drops to 3.8mA Above the measurement limit, the output rises to 20.8mA Sensor damage; Sensor open circuit (excluding thermocouple TC), output is 3.8mA Input current: ≤ 3.8mA Current limit: ≤ 20.8mA Environmental temperature: -40 to+85 ℃ Storage temperature: -40 to+100 ℃ Protection level: IP00, IP66 (installation) Cold end compensation: Built in cold end compensation Operation method: Adjust online through PC programming or manual controller Accuracy level: ≤ 0.2K or 0.08% Electrical isolation: 2KV Measurement variables: temperature (temperature linear transfer), resistance, and voltage Measurement range: The variation of the transmitter's measurement range depends on the sensor connection mode and input signal Voltage influence: negligible Environmental temperature impact: negligible (temperature drift) Condensation: allowed Seismic resistance: 4g/2-150Hz Installation angle: unlimited
|
|
|
4-20mA two-wire output Suitable for various types of thermistor sensorsPt100, Pt1000, Cu50, Cu100 type, etc DIN35rail-mounted installation
|
·type number:MTRS1 ·Output signal:4-20mATwo line system (please specify for special outputs) ·Supply voltage:24V DC(12~30V) ·Measurement range: User customized ·Accuracy level:±0.5%FS ±0.2%FS ±0.1%FS ·Ambient temperature-20~80℃ ·Functional features: Linear compensation, sensor disconnection alarm function ·Scope of application: Suitable for various types of thermistor sensorsPt100、Pt1000、Cu50、Cu100Type, etc ·Overall dimensions:94×24mm H41mm
· DIN35rail-mounted installation
|
|
4-20mA output
Suitable for various types of thermocouple temperature sensorsK. S, E, B, etc
DIN35 rail installation
|
·type number:MTCS1 ·Output signal:4-20mAtwo-wire system ·Supply voltage:24V DC(12~30V)(Please specify special outputs) ·Measurement range: User customized ·Accuracy level:±0.5%FS ±0.3%FS ·Ambient temperature-20~80℃ ·Functional features: automatic cold end compensation, sensor disconnection alarm function ·Scope of application: Suitable for various types of thermocouple sensorsK、S、E、Bwait ·Overall dimensions:94×24mm H41mm
· DIN35rail-mounted installation
|
|