test methodSelect a suitable test block based on the thickness of the test specimen and standard requirements. Place the calibrated twin crystal straight probe at position a in the schematic diagram, and move the probe back, forth, left, and right to obtain the maximum reflected echo of the direct sound beam on the φ 2 flat bottom hole. Adjust the echo amplitude to 80% of the full screen height and record the dB value at this time,This is the first pointPlace the probe at position b in the schematic diagram, and move the probe back, forth, left, and right to obtain the maximum reflected echo of the direct sound beam on the φ 2 flat bottom hole. Adjust the echo amplitude to 80% of the full screen height and record the dB value at this time,This is the second pointPlace the probe at position c in the schematic diagram, and move the probe back, forth, left, and right to obtain the maximum reflected echo of the direct sound beam on the φ 2 flat bottom hole. Adjust the echo amplitude to 80% of the full screen height and record the dB value at this time,This is the third pointRepeat this process until the range can cover the detection thickness (at least three points should be tested), and connect the above points into a curve, which is the distance amplitude curve of the twin crystal straight probe, and use it as the reference sensitivity. On this basis, a gain of 6dB is used as the scanning sensitivity.