- Phone
-
Address
Room 1919, Building 4, Gaosheng Times Square, No. 798 Zhongyi 1st Road, Yuhua District
Hunan Weimei Electric Technology Co., Ltd
Room 1919, Building 4, Gaosheng Times Square, No. 798 Zhongyi 1st Road, Yuhua District
Radar flowmeter for measuring water channel flowProduct Overview
radar flow meterIt refers to a product that uses radar to measure water flow velocity and liquid level, and converts water flow rate through an integral model. It can measure water flow in real-time 24/7, and non-contact measurement is not easily affected by the measurement environment. The product provides a fixed method for the bracket.
Radar flowmeter for measuring water channel flowProduct features
Non contact measurement based on hybrid frequency band radar, with simultaneous output of flow velocity, liquid level, and flow rate without interference, minimal maintenance, and unaffected by sediment and other factors
IP68 waterproof design, suitable for various outdoor environments, suitable for various J-end weather environments
Compact and compact appearance, super G cost-effectiveness
Integrated anti reverse connection, lightning protection, and overvoltage protection functions
Support Modbus RTU protocol for easy system access
Support Bluetooth debugging on mobile phones for easy maintenance by on-site personnel
Technical Specifications
Speed measurement range |
0.05 m/s ~40m/s |
speed measurement accuracy |
1% |
Speed measurement elevation angle(automatic compensation) |
0°- 80° |
Speed measuring antenna beam angle |
10°*27° |
Distance blind spot |
20cm |
Distance measurement Z large range |
65m |
ranging accuracy |
±1mm |
Ranging antenna beam angle |
6 ° |
Radar at a large distance of Z from the water surface |
65m |
power supply range |
7~28VDC |
operating current |
operating current 13-15ma@24V |
communication interface |
RS485(9600) |
communication protocol |
Modbus(9600/115200) |
Operating Temperature |
-40-70℃ |
Shell material |
aluminum alloy,PBT |
Sizemm) |
155mm*79mm*94mm |
Protection level |
IP68 |
Installation method |
support |
Installation Instructions
The flowmeter consists of two parts: a flow velocity measurement radar and a water level measurement radar. Among them, the flowmeter measures the Doppler of the water flow Frequency shift is used to calculate the flow velocity on the water surface; Liquid level measurement radar is similar to flow rate measurement radar in that it calculates the flight time of electromagnetic waves And calculate the distance between the radar and the water surface. The flowmeter measures the flow velocity and liquid level, combined with the actual cross-section of the river to be measured based on the input Based on the characteristics of the river, estimate the velocity distribution on the river section and use the corresponding dataThe empirical model calculates the river flow rate.
When installing a radar flowmeter, try to install it in reverse flow. When installed in reverse flow, the measurement signal is clearer and more accurate than when installed in parallel flow. When the measured water flow is only in reverse flow, the "measuring liquid flow direction" of the Jiang measurement flow rate radar is set to "reverse flow". This installation and setting not only make the measurement signal clearer and more accurate, but also avoid interference from rain, snow, and other factors at a high speed limit.