Welcome Customer !

Membership

Help

Shanghai Xuji Electric Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Xuji Electric Co., Ltd

  • E-mail

  • Phone

  • Address

    508, Building 4, Lane 680, Shuishe West Road, Baoshan District, Shanghai

Contact Now

RST2050 Insulation Rod Rope Quality Rapid Tester

NegotiableUpdate on 05/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

RST2050 Insulated Rod Rope Quality Rapid Tester Handheld Tester, keep away from the object being tested, long press the power button (POWER) until the battery level indicator light is on, then release it, and then press the self-test button (CHECK). The instrument will start self-test for about 5 seconds. Within 5 seconds, the insulation test light will be fully on and the buzzer will continue to beep. After 5 seconds, the insulation test light will turn off and the buzzer will stop beeping. The instrument will pass the self-test and exit the self-test state.

Product Details

RST2050 Insulation Rod Rope Quality Rapid InspectionMeasuring instrument


Self check of the detector: Before each use, the instrument self check must be completed in different environments to ensure that the sound and light alarm functions of the detector and the device itself are in normal condition.

Handheld detector, keep away from the object being tested, long press the power button(POWER)Release your grip until the battery level indicator light is on, then press the self-test button(CHECK)The instrument starts self checking, with a duration of approximately5 seconds. Within 5 seconds, the insulation test light will be fully on and the buzzer will continue to beep. After 5 seconds, the insulation test light will turn off and the buzzer will stop beeping. The instrumentSelf inspection passed,Exit the self check state. If any of the following situations occur, the instrument self-test fails and needs to be returned to the factory for repair:

l Insulation status indication within 5 secondsThe lights are not all on

l Buzzer within 5 secondsNo buzzing sound is emitted

l After 5 seconds, if the insulation test light is still flashing, it indicates that there is an internal fault in the instrument and the power button needs to be long pressed(POWER)Shut down.

If the instrument self-test fails, it should be checkedIs there any foreign object interference around the V-shaped groove or shell? If self inspection still fails, it needs to be returned to the factory for repair.

According to the diameter of the tested object such as insulation rods, bars, ropes, etcTurn the CALIBER knob to the corresponding caliber position. Note that for the tested object with a diameter exceeding 39mm, several repeated tests are required. Each time, the tested object is rotated 90 degrees to ensure that each surface is detected.The insulation rope includesΦ8mmandΦ13mmTwo gears, the insulation rod includesΦ10mmandΦ15mmTwo gears, the insulation rod includesΦ32mmTheΦ39mmTheΦ51mmTheΦ64mmandΦ77mmThere are five gears in total.

pressTest button,Green operating statusThe indicator light is flashing,Insulation status indicator light at the bottomTwo green lights are on, at this momentTranslate into EnglishinstrumentAlign the V-shaped electrode with the surface of the object being tested, and slide the detector until it passes through the detection completely. Observing the LED status light, only2The green light is on and in theOK zone, indicating that there are no issues with the tested object; once3 lights on until 8The light is on,Indicating a decrease in insulation performance, if9 lights or 10The lights are all on,If a buzzing sound is heard simultaneously, it indicates that the object being testedInsulation performanceunqualified.

After the detection is completed, pressTESTKey, insulation test light goes out, green running status indicator light stops flashing and remains on, press and hold the power button(POWER)The detector is turned off(If there is no operation for 10 minutes, the detector can automatically shut down.

The detector is powered by a large capacity lithium battery and can operate continuously under normal working conditions when fully chargedMore than 24 hours. When electricitybelow1 gridWhen,The battery level light will start flashing, reminding the user to charge. When the battery level drops below the minimum operating voltage, the detector will shut down directlyWhen charging, it shouldUsing randomly configuredCharge with a charger of 100V~240V/50Hz/60Hz and 29.4V/1A. When the instrument is not in use for a long time, it is recommended to charge and maintain it every three months to avoid damaging the battery due to self discharge.

Precautions for daily maintenance: If dust or dirt is adsorbed onOn the V-shaped electrode, it may affect the accuracy of the detection. The V-shaped electrode (including the roller) should be wiped clean immediately by applying isopropanol with a soft cloth.

The detector comes with a one-year warranty under normal usage conditions. If there is a malfunction, please return the instrument to the local dealer. Damage caused by improper operation, unauthorized disassembly, or human modification is not covered by the warranty. We reserve the right to make design or construction modifications to the instrument at any time, without violating the relevant regulations of the sold instrument.



RST2050 Insulation Rod Rope Quality Rapid InspectionMeasuring instrument

Features:

Adopting a new high-frequency measurement method, there is no AC/DC high voltage output, and the output voltage is lower than the safe voltage for human body, posing a risk of electric shockInsurance;

Bottom adoptsThe V-shaped card slot design allows for real-time detection of the insulation status of the entire tested object by sliding along its surface during measurement. The detection process is fast, efficient, and time-saving;

Adopting a multi electrode scheme to ensure good contact between objects of different sizes and meet different application requirements, the standard sizes of the objects are as follows:

l Insulation rod:Φ10Mm andΦ15mm

l Insulation rod:Φ32mm、Φ39mm、Φ51mm、Φ64Mm andΦ77mm

l Insulated rope:Φ8mm~Φ13mm

Equipped with self checking function, it can promptly detect equipment problems and prevent unpredictable safety accidents caused by misjudging the insulation status of the tested object due to instrument failures;

The human-machine interface is simple and easy to operate, using a multi segment light bar digital tube and buzzer to display the insulation status of the device, which is concise and clear.