E-mail
13913028277@163.com
-
Phone
13913028277
-
Address
Room 618, Tongchuang Building, No. 61 Sipailou, Xuanwu District, Nanjing City
Nanjing Ouxi Science and Trade Co., Ltd
13913028277@163.com
13913028277
Room 618, Tongchuang Building, No. 61 Sipailou, Xuanwu District, Nanjing City
RSA Aerobic Anaerobic Plastic Degradation Breather from the United StatesPF-8000
Aerobic anaerobic respiration apparatus |
Activated Sludge Breather |
Microbial degradation respiratory apparatus |
Aerobic respiration apparatus |
Anaerobic respiration apparatus |
Soil respiration meter |
Anaerobic Bioactivity Tester |
Wastewater Biochemical Treatment Evaluation Instrument |
Aerobic biological activity tester |
Anaerobic Toxicity Tester |
Wastewater biodegradation analyzer |
Compost degradation analyzer |
Plastic degradation tester |
Anaerobic Bioactivity Tester |
BOD analyzer |
RSA aerobic anaerobic respiration system from the United StatesGeneral purpose:
lAerobic biological activity testlBiodegradation testing of wastewater samples
lOxygen uptake rate(OUR)Fingerprint characteristicslAssess nutritional deficiencies
lFixed-point control of oxygen uptake rate in active sludge treatmentlBiodegradation kinetics of existing mixed wastewater
lMeasure short-termBODlThe intrinsic biodegradation kinetics of chemicals
lToxicity assessment of diluted sequenceslBiodegradability performance of oil stains and dirt
lAcute toxicity assessment of water treatment plantslOxygen uptake of soil and compost samples
lAnaerobic biological activity testinglAnaerobic Biochemical Methane Production Rate and Anaerobic Toxicity Testing
lMethane Potential in Sludge SampleslMonitor denitrification reaction
PF-8000 is suitable for but not limited to the following standard tests:
1:BiodegradabilityOECD301C,OECD301F
2:Inherent biodegradabilityOECD302C
3:Final biodegradabilityISO9408,ASTM D5338
4:Soil and compost oxygen consuming biodegradabilityISO17556
5:Activated sludge respiration inhibition test:OECD209
6:Anaerobic experimentsOECD224,OECD311
7:Anaerobic inhibition testISO13641-1; 13641-2
8:Anaerobic biodegradation experiment:ASTME2170-01,USEPA OPPT835.3400
9:national standardGB/T21218-2008,GB/T-21802-2008 ,GB/T21801-2008,GB7448-87
10:variousBOD:BOD3,BOD5,BOD5,BOD28,BOD42wait..

RSA Aerobic Anaerobic Plastic Degradation Breather from the United StatesProduct performance:
A respirator is a device used to detect activated sludge in wastewater biochemical treatment systems, mainly used to monitor the status of activated sludge in sewage treatment facilities, the operation of reactors, and process control. It determines the oxidation capacity and biomass in the biochemical wastewater treatment process by measuring the absorption of oxygen by activated sludge, and is therefore also known as the "sludge oxidation capacity detector".
The working principle of the activated sludge aerator is to mix the activated sludge sample with water containing a certain concentration of oxygen under certain temperature and stirring conditions, and then measure the amount of oxygen consumed over a certain period of time to determine the oxidation capacity of the activated sludge.
According to different measurement principles and display methods, activated sludge respirators can be divided into different types, such as portable and desktop, digital and analog, etc. Generally speaking, portable activated sludge respirators have the characteristics of small size, light weight, and easy operation, making them suitable for on-site use; Desktop activated sludge respirators typically have higher accuracy and more functional options, which can be used for laboratory measurement and analysis.
The three operating modes of RSA PF-8000 respiratory apparatus in the United States:
1. Aerobic mode:
Supply pure oxygen - small increments of pure oxygen are injected into each container of the respirator in response to the reduction of oxygen and carbon dioxide. This operating mode ensures stable oxygen concentration at the top of the reaction vessel, and oxygen is converted from the gas phase to the liquid phase by stirring with a magnetic stirrer.
2. Hypoxia or anaerobic mode:
The gas generated by the biological reaction flows into the internal storage chamber and is released after the pressure is detected by the built-in pressure sensor. This incremental RSA undergoes precise calibration before leaving the factory.
Number of reaction containers: 4, 8, 16, and 24 positions are optional. The 4-bit system can be expanded to 8 positions by adding an internal expansion module, and the 8-bit system can be expanded to 16 or 24 positions by adding a satellite flow control module. All units are connected to the same computer for data collection.
3. Operation mode:
All standard pulse respirators can operate in aerobic and anaerobic modes without the need to purchase any isolation control modules or other cumbersome hardware. Depending on requirements, a separate aerobic or anaerobic system can be provided.
The activated sludge aerator has important application value in the wastewater treatment process. By monitoring and controlling the state and evolution process of activated sludge, it can better ensure the treatment effect and operational stability of wastewater. Meanwhile, activated sludge breathers can also be used to study and evaluate the efficiency and feasibility of different wastewater treatment processes.
Number of reaction containers: 4, 8, 16, and 24 bit options are available. The 4-bit system can be expanded to 8 positions by adding an internal expansion module, while the 8-bit system can be expanded to 16 or 24 bit systems by adding a satellite flow control module. All units are connected to the same computer for data collection.
Reaction vessel: Unless for some special projects, RSA's pulse breathing apparatus uses standard glassware and most chemical companies can provide standard consumables. The standard reaction vessel is 500ml, and depending on the testing purpose, the reaction vessel can be selected from 250ml to 2L.
Sensitivity: The oxygen consumption increment is 0.05mg, and the maximum oxygen consumption rate of the standard system configuration is 1200mg/hr. By adding a simple plug-in flow expansion module, the rate can increase tenfold. Such a high rate can be used to detect experimental samples with high oxygen consumption.
Operating characteristics: - minimum oxygen uptake=0.03 mg; maximum oxygen uptake rate>1200 mg/hr (can be expanded to 12000 mg/hr or greater)
-Minimum gas flow rate=0.04 mL; maximum gas flow rate>1000 mL/hr (expandable to 10 L/hr)
-Working temperature: 5 to 70oC
-Sensitivity:<0.03 mg (aerobic),<0.04 mL (anaerobic) - Accuracy:<3% CV aerobic and anaerobic