Phone
13601394642
-
Address
No. 65 Mujin Road, Ningbo National High tech Zone
Ningbo Xinzhi Biotechnology Co., Ltd
13601394642
No. 65 Mujin Road, Ningbo National High tech Zone
| model | RQ1210G |
| Experimental device | 12+2 channels |
| temperature resolution | 0.01℃ |
| stirring speed | 25RPM—250RPM |
| Mixing speed resolution | 0.1RPM |
| Lighting System | Red light, white light |
| sampling times | 16 times |
| Continuous working hours | 99 hours 59 minutes x 16 |
| Sampling and filtering cycle | <30 seconds |
| Sampling volume (or fluid replacement volume) | 1ml—100ml |
| Single tube allocation quantity | 0ml—15ml |
| Sampling accuracy | RSD1%(10ml) |
| user program | 99 of them |
| subscriber number | 7 users |
| User level | three-level |
| record keeping | 128 records * 366 days |
DESCRIPTION
The RQ1210G dissolution sampling collection system consists of an RC1210G dissolution experimental instrument and a QY12 sampler connected in series. 14 dissolution cups and 2 isothermal infusion cups, using a twelve channel precision injection pump to achieve high-precision automatic filtration, sampling, and infusion, in compliance with the 2015 edition of the Chinese Pharmacopoeia and the United States Pharmacopoeia.
Product Features
|
• Can conduct experiments using basket method, paddle method, small cup method, disc method (large and small discs), and rotary tube method (long and short tubes) to meet the requirements of blank and control • Electric lifting of the machine head • Automatic fixed height clutch • Synchronous dosing and sequential dosing functions Dual color lighting system Using precision glass syringes as sampling power Adopting high-precision, high pressure resistance, and high chemical stability valve body •Built in micro printer • Optional WiFi, Bluetooth, RS232, RS485 expansion interfaces 16 position test tube rack, capable of holding up to 192 test tubes High sensitivity capacitive touch screen •Multi user management • Permission management • Audit trail |
frequently asked questions
|
What is the difference between automatic sampling and manual sampling? Answer: The Chinese Pharmacopoeia stipulates that the time interval for sampling and filtering should not exceed 30 seconds. Manual sampling may exceed the specified time, resulting in inaccurate experimental data. Automatic sampling can avoid this error problem. 2. If the sample is a volatile substance, are there measures to reduce its volatility? Answer: For volatile drugs, the accessory test tube of the Xinzhi drug testing dissolution sampling collection system will be equipped with a test tube cap, which not only prevents their volatilization but also blocks dust and other debris. |