Welcome Customer !

Membership

Help

Shanghai Fanbiao Textile Testing Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Shanghai Fanbiao Textile Testing Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    2578 Gudai Road, Minhang District, Shanghai

Contact Now

RE type male side impact dummy car crash test dummy

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The RE type male side impact dummy for car collision testing is a side impact test dummy designed based on the statistical characteristics of the 50th percentile adult male human body. It is mainly used to simulate the biomechanical response of passengers in the event of a vehicle side impact. The dummy has undergone structural improvements in response to the new requirements of FMVSS 214 regulations in the United States

Product Details

The RE type male side impact dummy is a side impact test dummy designed based on the statistical characteristics of adult males at the 50th percentile. It is mainly used to simulate the biomechanical response of passengers in a vehicle during a side impact. The dummy has undergone structural improvements in response to the new requirements of FMVSS 214 regulations in the United States. By optimizing the rib structure and introducing rib extension devices, it has a more realistic mechanical response ability when interacting with the seat and door interior. It can be used to evaluate the lateral structural impact resistance and the effectiveness of passenger lateral restraint systems.


RE型男性侧面碰撞假人  汽车碰撞测试假人




Product Specifications

serial number
name Size (mm)
1 sitting height 909±9
2 Seat to Shoulder Joint 565±7
3 Seat to lower surface of thoracic spine box 351±5
4 Seat to hip joint (bolt center) 100±3
5 From feet to seat, sitting posture 442±9
6 head width 155±3
7 Shoulder and arm width 470±9
8 Chest width 327±5
9 Abdominal width 280±7
10 Pelvic valve width 366±7
11 head depth 201±5
12 Chest depth 267±5
13 Abdominal depth 199±5
14 Pelvic depth 240±5
15
From the back of the buttocks to the hip joint (bolt center) 155±5
16 From the back of the buttocks to the front knee 606±9

Quality distribution:

component Mass (kg)
head 4±0.05
neck 1±0.05
chest 22.4±1
left arm 1.3±0.1
Right arm 1.3±0.1
abdomen 5±0.25
pelvis 12±0.6
left leg 12.7±0.6
right leg 12.7±0.6
sum 72.4±1.2

Sensor configuration:

Installation location Sensor Name 通道
head Accelerometer 3×1
Upper neck 6-channel force sensor 1×6
Lower neck 6-channel force sensor 1×6
shoulder
3-channel force sensor 1×3
chest inclination sensor 1×2
trunk 4-channel force sensor 1×4
Thoracic T1
Accelerometer 1×3
Thoracic T12 Accelerometer 3×1
rib Accelerometer 3×1
rib Linear potentiometer 3×1
Thoracic T12 4-channel force sensor 1×4
abdomen Single channel force sensor 3×1
Lower lumbar spine 3-channel force sensor 1×3
pelvis inclination sensor 1×2
pubis Single channel force sensor 1×1
sacrum Accelerometer 3×1
thigh 6-channel force sensor 1×6