Welcome Customer !

Membership

Help

Yangzhou Fluke Electric Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Yangzhou Fluke Electric Co., Ltd

  • E-mail

  • Phone

  • Address

    Chengxi Industrial Zone, Baoying County, Yangzhou City, Jiangsu Province

Contact Now

Quotation from DC high-voltage generator manufacturer

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Easy to operate, fully functional, and convenient for outdoor use, it is a reliable product of the new century. According to the maintenance free design, the main components are made of new technology imported from countries such as the United States, Germany, and Japan, which are durable and not afraid of continuous short circuit discharge to ground. High precision and accurate measurement. The voltage and current meters are both digital displays with a voltage resolution of 0.1kV and a current resolution of 0.1uA. The voltage meter on the control box directly displays the voltage value applied to the load test sample without the need for an external voltage divider during use, and the wiring is simple. The instrument has high and low voltage terminals to measure leakage current

Product Details

Quotation from DC high-voltage generator manufacturer

Smaller in size, lighter in weight, more aesthetically pleasing, more reliable, easy to operate, fully functional, and convenient for outdoor use, it is a reliable product of the new century.

According to the maintenance free design, the main components are made of new technology imported from countries such as the United States, Germany, and Japan, which are durable and not afraid of continuous short circuit discharge to ground.

High precision and accurate measurement. The voltage and current meters are both digital displays, with a voltage resolution of0.1kVThe current resolution is0.1uAThe voltmeter on the control box directly displays the voltage value applied to the load test sample, without the need for an external voltage divider during use, and the wiring is simple. The instrument has high and low voltage ends for measuring leakage current, and the high voltage end is displayed with a circular shielded digital meter, which is not afraid of discharge shock and has good anti-interference performance, suitable for on-site use.

The voltage regulation has high stability and smooth voltage regulation across the entire range. The output voltage regulation adopts an imported single multi turn potentiometer, which ensures a smooth boosting process and high adjustment accuracy. It is also designed with coarse and fine adjustment functions. Voltage regulation accuracy is better than0.1%The measurement error of voltage and current is less than1%The pulsation factor is better than0.5%.

Negative polarity output, zero start, continuously adjustable, with various protection functions such as overvoltage, overcurrent, return to zero, grounding protection, and * disconnection protection. The automatic protection circuit has strong functions, reliable protection, and ensures safe operation. All technical indicators are superior to industry standards and superior to similar products.

Added high precision75%VDC-1mAThe function of zinc oxide lightning arrester measurement brings convenience. A gentle press does not require calculation. There are on the control box of this instrument75%The voltage function key, when conducting lightning arrester tests, when the current rises to1000uAOpen it at the right time0.75The button displays the values on the voltmeter and ammeter75%After completing the data, the boost knob should be immediately returned to the zero position, and the fine adjustment voltage knob should be returned to the zero position. The green button should be immediately pressed to cut off the high voltage and turn off the power switch. Conduct other experiments.

Product specifications and technical performance

Specifications

Technical Specifications

60/2

100/2

100/10

160/2

180/2

200/2

250/2

100/200

3/2

200/300

3/2

other

Grade

Output voltage (kV)

60

100

100

160

180

200

250

100/200

200/300

600~800kV

Can be customized later.

Output current (mA)

2

2

10

2

2

2

2

3/2

3/2


Output power (W)

120

200

1000

320

360

400

500

400

600


charging current

(mA)

3.0

3.0

12.0

3.0

3.0

3.0

3.0

4.5/3.0

4.5/3.0


Chassis weight (kg)

4.3

4.3

5.3

4.3

4.3

4.4

4.5

4.5

8.1


Double pressure cylinder size (mm)

Φ80

×500

Φ80

×620

Φ80

×770

Φ80

×770

Φ110

×770

Φ110

×770

Φ110

×820

Φ110

×800

Φ110

×1350


Double pressure weight (kg)

6.3

6.8

7.5

7.2

7.2

7.2

7.6

7.5

12.6


High voltage polarity

Negative voltage polarity, zero voltage start, continuously adjustable.

working power supply

AC 220V±10%; 50Hz

Voltage measurement accuracy

1%(Full scale) ± 1 word, resolution 0.1% kV

Accuracy of current measurement

1%(Full scale) ± 1 word, resolution 0.1% uA

Overvoltage setting accuracy

≤1.0%

0.75Switching accuracy

≤0.5%

Ripple coefficient

≤1.0%

Voltage stability

Random fluctuation, ≤ 0.5% when the power supply voltage changes by ± 10%

working method

Intermittent use; Rated load for 30 minutes; 1.1 times rated voltage usage: 10 minutes

ambient temperature

-15℃~50℃

relative humidity

When the temperature is 25 ℃, not more than 90% (no condensation)

altitude

2500Below meters