- Phone
-
Address
Chengxi Industrial Zone, Baoying County, Yangzhou City, Jiangsu Province
Yangzhou Fluke Electric Co., Ltd
Chengxi Industrial Zone, Baoying County, Yangzhou City, Jiangsu Province
Quotation from DC high-voltage generator manufacturer
Smaller in size, lighter in weight, more aesthetically pleasing, more reliable, easy to operate, fully functional, and convenient for outdoor use, it is a reliable product of the new century.
According to the maintenance free design, the main components are made of new technology imported from countries such as the United States, Germany, and Japan, which are durable and not afraid of continuous short circuit discharge to ground.
High precision and accurate measurement. The voltage and current meters are both digital displays, with a voltage resolution of0.1kVThe current resolution is0.1uAThe voltmeter on the control box directly displays the voltage value applied to the load test sample, without the need for an external voltage divider during use, and the wiring is simple. The instrument has high and low voltage ends for measuring leakage current, and the high voltage end is displayed with a circular shielded digital meter, which is not afraid of discharge shock and has good anti-interference performance, suitable for on-site use.
The voltage regulation has high stability and smooth voltage regulation across the entire range. The output voltage regulation adopts an imported single multi turn potentiometer, which ensures a smooth boosting process and high adjustment accuracy. It is also designed with coarse and fine adjustment functions. Voltage regulation accuracy is better than0.1%The measurement error of voltage and current is less than1%The pulsation factor is better than0.5%.
Negative polarity output, zero start, continuously adjustable, with various protection functions such as overvoltage, overcurrent, return to zero, grounding protection, and * disconnection protection. The automatic protection circuit has strong functions, reliable protection, and ensures safe operation. All technical indicators are superior to industry standards and superior to similar products.
Added high precision75%VDC-1mAThe function of zinc oxide lightning arrester measurement brings convenience. A gentle press does not require calculation. There are on the control box of this instrument75%The voltage function key, when conducting lightning arrester tests, when the current rises to1000uAOpen it at the right time0.75The button displays the values on the voltmeter and ammeter75%After completing the data, the boost knob should be immediately returned to the zero position, and the fine adjustment voltage knob should be returned to the zero position. The green button should be immediately pressed to cut off the high voltage and turn off the power switch. Conduct other experiments.
Product specifications and technical performance
|
Specifications Technical Specifications |
60/2 |
100/2 |
100/10 |
160/2 |
180/2 |
200/2 |
250/2 |
100/200 3/2 |
200/300 3/2 |
other Grade |
Output voltage (kV) |
60 |
100 |
100 |
160 |
180 |
200 |
250 |
100/200 |
200/300 |
600~800kV Can be customized later. |
Output current (mA) |
2 |
2 |
10 |
2 |
2 |
2 |
2 |
3/2 |
3/2 |
|
Output power (W) |
120 |
200 |
1000 |
320 |
360 |
400 |
500 |
400 |
600 |
|
|
charging current (mA) |
3.0 |
3.0 |
12.0 |
3.0 |
3.0 |
3.0 |
3.0 |
4.5/3.0 |
4.5/3.0 |
|
Chassis weight (kg) |
4.3 |
4.3 |
5.3 |
4.3 |
4.3 |
4.4 |
4.5 |
4.5 |
8.1 |
|
Double pressure cylinder size (mm) |
Φ80 ×500 |
Φ80 ×620 |
Φ80 ×770 |
Φ80 ×770 |
Φ110 ×770 |
Φ110 ×770 |
Φ110 ×820 |
Φ110 ×800 |
Φ110 ×1350 |
|
Double pressure weight (kg) |
6.3 |
6.8 |
7.5 |
7.2 |
7.2 |
7.2 |
7.6 |
7.5 |
12.6 |
|
High voltage polarity |
Negative voltage polarity, zero voltage start, continuously adjustable. |
|||||||||
working power supply |
AC 220V±10%; 50Hz |
|||||||||
Voltage measurement accuracy |
1%(Full scale) ± 1 word, resolution 0.1% kV |
|||||||||
Accuracy of current measurement |
1%(Full scale) ± 1 word, resolution 0.1% uA |
|||||||||
Overvoltage setting accuracy |
≤1.0% |
|||||||||
0.75Switching accuracy |
≤0.5% |
|||||||||
Ripple coefficient |
≤1.0% |
|||||||||
Voltage stability |
Random fluctuation, ≤ 0.5% when the power supply voltage changes by ± 10% |
|||||||||
working method |
Intermittent use; Rated load for 30 minutes; 1.1 times rated voltage usage: 10 minutes |
|||||||||
ambient temperature |
-15℃~50℃ |
|||||||||
relative humidity |
When the temperature is 25 ℃, not more than 90% (no condensation) |
|||||||||
altitude |
2500Below meters |
|||||||||