- Phone
-
Address
2nd Floor, Building 2, Wild Medical Electronics Industrial Plant, No. 24 Qinglan 3rd Road, Jinsha Community, Kengzi Street, Pingshan District, Shenzhen City, Guangdong Province
Clark (Shenzhen) Automation Technology Co., Ltd
2nd Floor, Building 2, Wild Medical Electronics Industrial Plant, No. 24 Qinglan 3rd Road, Jinsha Community, Kengzi Street, Pingshan District, Shenzhen City, Guangdong Province
QZX21 automatic air supply device CLAKE for pressurized oil tanks
The automatic air supply device consists of imported electric ball valves a and b, one-way valve c, two-way manual ball valves d, e, f, and filter g.
QZX21 automatic air supply device CLAKE for pressurized oil tanks
The schematic diagram is shown below: P is the gas source, and the arrow indicates the direction of air supply.
1. Automatic air supply and stop: The two-way manual ball valve D is closed. When the automatic air supply conditions are met, the electric ball valve b is automatically closed and the electric ball valve a is opened. High pressure air is supplied from the inlet P ->electric ball valve a ->one-way valve c ->to the pressure oil tank Q. When the condition for stopping air supply is met, the electric ball valve A will automatically close to stop air supply. Open the electric ball valve b, and the air pressure of the pressure oil tank Q is blocked by the one-way valve c, stopping the air supply. The pipe section between electric ball valve a and one-way valve c is emptied to atmospheric pressure through electric ball valve b, and the sealing of one-way valve c is enhanced. At the same time, prevent electric ball valve A from leaking and replenishing air.
2. Manual air supply and stop: The two-way manual ball valve D is closed. Close electric ball valve b and open electric ball valve a through the manual knob of the electric ball valve to achieve manual air supply. High pressure air flows from P through electric ball valve a ->one-way valve c ->to pressure oil tank Q for air supply. When the pressurized oil tank is filled with gas Q, close the electric ball valve A through the manual knob of the electric ball valve to stop the gas supply. Open the electric ball valve b through the manual knob of the electric ball valve, and the air pressure of the pressure oil tank Q is blocked by the one-way valve c, stopping the air supply. The pipe section between electric ball valve a and one-way valve c is emptied to atmospheric pressure through electric ball valve b, and the sealing of the one-way valve is enhanced. At the same time, prevent electric ball valve A from leaking and replenishing air.
3. When it is necessary to exhaust high-pressure gas during maintenance, turn off the control power and move the two-way manual ball valve to the exhaust position for exhaust. Note: When manually replenishing and exhausting air, the power must be turned off. Automatic air supply device achieves zero differential pressure operation; The large flow rate greatly shortens the air supply time and overcomes the disadvantages of low working flow rate and poor sealing performance of pilot operated solenoid valves under low pressure and high pressure; At the same time, due to the low requirement for gas cleanliness of electric ball valves, the gas replenishment device also has many advantages such as strong anti fouling ability and high pressure resistance
CLAKETop cover level gauge
LTF21-600/800/5-45-FN-T31/TOO,Magnetic induction split type, range:0-600mm,insertion depth800mm, with10Rice cable, equipped with voltage stabilizing bucket and welding bracket
CLAKETop cover liquid level switch
LSL11-600/22/2/3-250/300/500Connecting rod float level switch, rod length600mm,3Alarm contact output, action pointL1=250,L2=300,L3=500Outer diameter of floating ball28mm,L1=250MM(Start the backup water pump) L2=300MM(Start the main water pump) L3=500MM(Stop the pump) L=600MMThree pairs of contacts;
CLAKEThrust oil mixed water signal device
WI011-WW/2Contact capacity:1A/30VDC,G1/2External thread,5%Moisture content, measurement range0~10%;2For alarm contacts,4~20mAOutput; power supplyDC24VSide mounted, connection method: threaded connection.
CLAKEUpper guide oil mixed water signal device
WI011-WW/2Contact capacity:1A/30VDC,G1/2External thread,5%Moisture content, measurement range0~10%;2For alarm contacts,4~20mAOutput; power supplyDC24VSide mounted, connection method: threaded connection.
CLAKELower guide oil mixed water signal device
WI011-WW/2Contact capacity:1A/30VDC,G1/2External thread,5%Moisture content, measurement range0~10%;2For alarm contacts,4~20mAOutput; power supplyDC24VSide mounted, connection method: threaded connection.
CLAKEWater guide oil mixed water signal device
WIO21-400-WW/2-T00Top mounted, insertion depth400mm(Adjustable insertion depth), contact capacity:1A/30VDC,G1/2External thread,5%Moisture content, measurement range0~10%;2For alarm contacts,4~20mAOutput; power supplyDC24VConnection method: flange connection.
CLAKESubmerged plant floating ball level switch
LSL11-500/45/2/2-T00; Pole length:0.5Rice; Switching output:2Road(2Each action point is located at a distance from the bottom of the pole50mmand130mm)Material of measuring rod304Stainless steel, direct lead wire2m
CLAKEWaterproof flooded plant liquid level monitoring box
DWS11-T00;Inches are:700(tall)×400(wide)×200(deep)mmMade of stainless steel material. wall-mounted installation,Equip terminal block; Including other accessories
Statement:
1、 “Clake”、“Follow me,”Clark "and" Kereke "are brands that our company has been operating for many years, and we have never set up branches or offices in other cities in China.
2. Recently, it has been discovered that in Xi'an, Shanghai, Hubei and other places, there have been cases of counterfeiting our company's product models under the name of our office and branch for multiple website promotions and sales, seriously damaging the rights and interests of our company and users; Please carefully verify the purchasing channels of all dealers and users to avoid unnecessary losses.
Our company's products are now equipped with a new anti-counterfeiting label. Upon receiving the product, you can scan the code to check its authenticity and work together to eliminate itFake and inferior products!