Gas detector with displayThe QD6330 gas detection transmitter with display can be applied to flammable and explosive gas leakage sites as well as chemical plants with toxic and harmful substances. The gas detection instrument adopts the latest catalytic combustion sensor from abroad and the electrochemical sensor technology imported from the United States. The product has the advantages of stable signal and high accuracy. The instrument housing adopts a one-time molded explosion-proof and explosion-proof design made of cast aluminum, and the wiring method is suitable for various hazardous areas.
Instruments are widely used in pharmaceutical, chemical fertilizer, natural gas pipeline network, sewage treatment, municipal, iron and steel smelting, chlorine gas plants, acetylene plants, refrigeration workshops, chemical workshops, gas station areas, boiler rooms, hotel kitchen operation rooms and other places that require gas and fire prevention and explosion prevention.
Product Features:
◆ Alarm record query function
◆ Adjustable detection accuracy and range
◆ Long lifespan, high sensitivity, low drift, stable and reliable operation
◆ Sensor fault self check, two-level concentration alarm, with relay output function
◆ LCD or digital display of gas concentration and working status
◆ Equipped with temperature compensation and automatic zero point correction function
4-20mA or RS485 digital output, can be uploaded to DCS and PLC systems
◆ Infrared remote control method, the detector can be adjusted without opening the cover, safe and convenient
◆ Adopting explosion-proof design suitable for hazardous conditions Zone 1 and Zone 2
Technical parameters:
Detection principle: catalytic/electrochemical;
Sampling method: natural diffusion;
Display mode: 4-digit LED digital tube displays concentration value;
◆ Status indication: 3 LED lights indicate power supply and secondary alarm;
Debugging method: infrared remote control;
◆ Environmental temperature: -20 ℃~70 ℃;
Relative humidity:<95%;
Explosion proof method: Explosion proof type;
Explosion proof rating: Ex d Ⅱ C T6 Gb
Power supply: DC24V ± 25%;
Output signal: RS485 or 4-20mA
◆ Switching quantity: 2 (Level 2 alarm point normally open);
Power consumption: ≤ 3W;
◆ Cable usage: Bus ≥ 1.5mm2 × 4; Branch line ≥ 1.5mm2 × 3
Large distance between detector and host: ≤ 1000m
◆ Whole machine weight: ≤ 1500g
Pressure limit: 86kPa~106kPa
Explosion proof certificate number: CNEX12.3355
Measurement mark: Yuzhi 01000109
|
Tested gas
|
measurement range
|
Optional range
|
resolution
|
response time
|
|
Flammable EX
|
0-100%LEL
|
0-100% VOL (infrared)
|
1%LEL/1%vol
|
≤ 15 seconds
|
|
Carbon monoxide CO
|
0-1000PPm
|
0-500/2000/5000PPm
|
0.1/1PPm
|
≤ 15 seconds
|
|
TVOC
|
0-100PPM
|
0-100PPM
|
0.1PPm/1PPM
|
≤ 20 seconds
|
|
hydrogen
|
0-100%LEL
|
0-1000PPM
|
1%LEL/1PPM
|
≤ 20 seconds
|
|
natural gas
|
0-100%LEL
|
0-100%LEL
|
1%LEL
|
≤ 15 seconds
|
|
Oxygen O2
|
0-30%VOL
|
0-30%、0-100%VOL
|
0.1%vol
|
≤ 15 seconds
|
|
Ozone O3
|
0-10PPm
|
0-20、100PPm
|
0.01PPm/0.1PPM
|
≤ 20 seconds
|
|
Hydrogen sulfide H2S
|
0-100PPm
|
0-50、200、1000PPm
|
1/0.1PPm
|
≤ 15 seconds
|
|
methane
|
0-100%LEL
|
0-100%VOL
|
1%LEL/1%vol
|
≤ 15 seconds
|
|
Fluorine gas
|
0-10PM
|
0-1、10PPM
|
1/0.1PPm
|
≤ 20 seconds
|
|
hydrogen chloride
|
0-20PPm
|
0-20/50PPm/100PPM
|
0.01/0.1PPm
|
≤ 20 seconds
|
|
Nitrogen N2
|
0-30%VOL
|
0-30%VOL、100%VOL
|
0.1%LEL/1PPM
|
≤ 15 seconds
|
|
Hydrogen H2
|
0-100%LEL
|
0-1000PPm
|
1%LEL/0.1PPm
|
≤ 20 seconds
|
|
Chlorine gas CL2
|
0-20PPm
|
0-10、100PPm
|
0.1PPm
|
≤ 20 seconds
|
|
Ammonia NH3
|
0-100PPm
|
0-50、500、1000PPm
|
1/0.1PPm
|
≤ 20 seconds
|
|
nitrogen oxides
|
0-20PPm
|
0-50、1000PPm
|
0.1/1PPm
|
≤ 20 seconds
|
|
formaldehyde
|
0-20PPm
|
0-50、100PPm
|
1/0.1PPm
|
≤ 20 seconds
|
|
Sulfur dioxide SO2
|
0-20PPm
|
0-50、1000PPm
|
0.1/1PPm
|
≤ 20 seconds
|
|
Nitric oxide NO
|
0-250PPm
|
0-500、1000PPm
|
1PPm
|
≤ 20 seconds
|
|
Nitrogen dioxide NO2
|
0-20PPm
|
0-50、1000PPm
|
0.1/1PPm
|
≤ 20 seconds
|
|
phosphine
|
0-20PPm
|
0-20、100PPm
|
0.1PPm
|
≤ 20 seconds
|
|
acrylonitrile
|
0-100PPM
|
0-100PPm
|
0.1/1PPm
|
≤ 20 seconds
|
|
carbon dioxide
|
0-5000PPm
|
0-1%/5%/10% VOL (infrared)
|
1PPM/0.01%VOL
|
≤ 20 seconds
|
|
hydrogen fluoride
|
0-10PPm
|
0-1、10、50、100PPM
|
0.01/0.1PPm
|
≤ 20 seconds
|
|
Xylene, toluene
|
0-20PPm
|
0-5、10、50、100PPm
|
0.01/0.1PPm
|
≤ 20 seconds
|
|
Ethylene oxide ETO
|
0-100PPm
|
0-100PPm
|
1/0.1PPm
|
≤ 20 seconds
|
|
Please contact the company for unlisted gases
|
Standard Configuration: One detector
a remote control
One manual
One certificate of conformity and warranty card