Programmable bidirectional communication source carrier system

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The programmable bidirectional AC source load system is a four quadrant AC source load system with wide frequency, high power density, high precision, and high dynamics. Adopting the third-generation wide bandgap semiconductor device SiC design, an ultra-high power density design of 3U/25kVA has been achieved; The frequency supports 15-5000Hz output, meeting the requirements of higher frequency application scenarios. The G9000 integrates source load function and can simultaneously simulate abnormal power grid environments and various load characteristics. Widely covering optical storage, new energy vehicles, and AC/DC charging

Product Details

1、 Product Overview

Programmable bidirectional communication source carrier systemIt is a wide frequency device High power density high precision High dynamic four quadrant AC source load system . Adopting the third-generation wide bandgap half Conductor device SiC design achieved 3U/25kVA Ultra high power density design; Frequency support 15-5000Hz output Meet higher frequency requirements Scenario requirements . Integrated source loading function Can be achieved simultaneouslySimulate abnormal power grid environments and various load characteristics.Wide coverage of optical storage new energy vehicle AC/DC charging station aerospace research institution Testing fields such as higher education institutions.

可编程双向交流源载系统

appearance diagram

2、 Product Highlights

2.1 Ultra high power density

Programmable bidirectional communication source carrier systemSingle machine maximum support 3U/25kVA compact size lightweight High space utilization rate.

2.2 Integrated AC and DC

Capable of AC and DC output maximum support 650Vdc DC transmissionout And the maximum current in DC mode is the same as the effective value in AC mode.

2.3 brief interruption

Support simulation of power grid 1ms Interrupt working conditions.

2.4 Flexible parallel operation

The maximum power of a single machine can reach 25kVA Flexible andMachine achieves higher power expansion And the performance parameters after parallel operation are consistent with those of a single machine.

3、 Product specifications

3.1Model Description

可编程双向交流源载系统

3.2 Product Genealogy

l Professional Edition

model

rated power[kVA]

voltage range[V]

rated current[A]

Output phase number

S7200P-30K-2400-80

25kVA

450V

105A

single-phase/Three phase

4、 Technical parameters

4.1 technical indicators

AC output

rated value

output voltage

L-N/0~450V L-L/0 ~779V

output current

35A @ Three phase

105A @ single-phase

output power

25kVA

voltage

resolution

0.01V

precision

≤0.05%+0.05%F.S.

load regulation rate

≤0.05%F.S.

Source regulation rate

≤ 0.01% F.S. @ 10% change

Voltage distortion

< 0.3%@50Hz/60Hz

< 1%@15Hz400Hz

current

resolution

0.01A

precision

0.1%+0.1%F.S.

peak

105A @Three phase

315 @Single phase

frequency

set the scope

15Hz 1000Hz

resolution

0.01


model

G9000P-25K-450-105


precision

0.01%

phase

set the scope

0 ~359.9°

precision

±0.1°

resolution

±0.1°

harmonic

frequency

100 times @ 40-70Hz

25 times @ 71-400Hz

content

40%

DC output

rated value

output voltage

650V

output current

105A

output power

25kW

voltage

resolution

0.01V

precision

≤0. 1%F.S.

load regulation rate

≤0.025%F.S.

Source regulation rate

≤ 0.01% F.S. @ 10% change

AC input

rated value

input voltage

342V ~528V

input frequency

47 63Hz

phase

3 phases 4 lines

Maximum input current

35A

power factor

0.99

Load parameters

voltage

input voltage

30-450V

display resolution

0.01V

display precision

< 0.1%+0.1% F.S.

current

input current

105A @ single-phase 35A @ Three phase

Set resolution

0.01A

display resolution

0.01A

Current accuracy

< 0.2% + 0.2% F.S.

frequency

frequency range

15-400Hz

display resolution

0.01Hz

precision

0.01%

power

input power

25kVA

Set resolution

1VA

display resolution

1VA

precision

< 0.4% +0.4% F.S.

power factor

scope

-1~ 1

Set resolution

0.001

Peak factor

scope

1.414 ~3

resolution

0.001

resistor

scope

0.3 ~333.33 Ω single-phase



model

G9000P-25K-450-105



0.9 ~1000 Ω three-phase

resolution

0.001Ω

precision

< 0.3%+0.3% F.S.

P active power(kW)

Set range

0~25kW(Three phase)/0 ~25kW(Single phase)/0 ~8.3kW(Three phase independent)

resolution

0.001kW

QL Reactive power

(kVar)

Set range

0~25kVar(Three phase)/0 ~25kVar(Single phase)/0~83kVar(Three phase independent)

resolution

0.001kVar

QC Capacitive reactive power

(kVar)

Set range

0~25kVar(Three phase)/0 ~25kVar(Single phase)/0~83kVar(Three phase independent)

resolution

0.001kVar

RLC

R scope

0.9-1000Ω

Set resolution(Ω)

0.1Ω

L scope

1~5000mH(Three phase)/0.33 ~1666.67mH(Single phase)

Set resolution(mH)

0.5mH

C scope

1~5000uF(Three phase)/3 ~15000uF(Single phase)

Set resolution(uF)

0.1uF

Rc scope

0.9~ 1000 Ω (three-phase)/0.3~333.33 Ω (single-phase)

RL scope

0.9~ 1000 Ω (three-phase)/0.3~333.33 Ω (single-phase)

General Parameters

pressure resistance

1500Vdc

Peak efficiency

90%

protection level

IP20

Storage temperature

-20℃ ~ +70℃

Operating Temperature

0~40℃

humidity

0 90%RH No condensation at 25 ℃

altitude

2000m

communication interface

RS232/LAN/CAN/USB/SimulationIO/Number IO

Size( mm

699 (D) ×445 (W) × 133 (H)

weight

40kg

If there are any updates to the above specifications No further notice will be given.

4.2 Optional Configuration

Optional features

GPIB communication interface

Universal Interface Bus Communication

5、 Function Description

The G9000 series has flexible operating modes support AC The DCThe AC+DC output mode among which AC The mode has three-phase linkage/Three phase independent/Single phase operation mode Can independently set amplitude Frequency and phase, etc . Its output has a step size gradient pulse Harmonic superposition between harmonics high Multiple operating modes such as low voltage crossing; Programming data can be saved And supports import and export.

5.1 Sine wave mode

In this mode, the output voltage can be set phase amplitude frequency value The minimum set step size is: 0.01V The 0.01Hz adjustable The output mode is three-phase linkage/Three phase independent/singleSet up accordingly.

The amplitude of each phase's voltage is the same when connected Phase angle difference 120 ° ;可编程双向交流源载系统

Sine wave mode Three phase linkage@220V , phase difference120°

Three phase independence allows users to test simultaneously 3 independent test pieces Without the need for additional hardware configuration.

可编程双向交流源载系统

Sine wave mode Three phase independent@Different amplitudes Phase A 60 ° B 200 ° C Phase 100 °

Can output in single-phase mode 105A;

Sine wave mode single-phase@220V

AC+DC output mode

可编程双向交流源载系统

AC+DC@150V/50Hz , overlay100Vdc 0 ° trigger可编程双向交流源载系统

DC+ AC@200Vdc Overlay 50Vac , frequency15Hz-100Hz-15Hz variation

5.2 LIST/STEP/PULSE mode

possess LIST The STEP and PULSE Waiting for multiple programming output modes STEP and PULSE The mode provides single step or continuous voltage fluctuations use To simulate power interference such as periodic transients Instantaneous high pressure Gradual voltage drop, etc; LIST Mode programmableCompile more complex test waveforms support 10 sets of work steps edit Each group can be set 20 sequences And the steps can be set cyclically At the same time, the waveform can contain AC and DC Almost all the letters you want can be composed ofHao Bo form . Can simulate various voltage transients Interrupted and mutated waveforms.

可编程双向交流源载系统

LIST mode @ voltage 220-180-20-160V step change

可编程双向交流源载系统

STEP mode @ voltage 50-220V , frequency45-65Hz Gradual change within 10 seconds

PULSE mode @ total cycle time of 1 second Proportion of pulse time50% Pulse voltage100V , frequency100Hz

5.3 High and low pressure crossing

Capable of wearing high clothing Wear low High and low penetration joint testing function Can achieve single-phase operation two-phase Three phase equal crossing test.Nominal voltage 220V , A-phase drop phase angle 0 ° , 0 falls and recovery time<1ms

可编程双向交流源载系统

voltage220V 0 wear maintenance time 1ms A-phase drop phase angle 180 ° voltage220V A-phase drop phase angle 270 ° (zero crossing)

High and low voltage combined ride through test;

可编程双向交流源载系统

Rated voltage220V Wearing low20% Wearing high clothing 130% A-phase drop phase angle 0 °

5.4 Harmonic Mode/Interharmonic Mode

In harmonic superposition mode, the harmonic amplitude of each voltage can be set Simulate abnormal power grid environment To test the power grid of the tested equipmentTolerance ability. 2-100th harmonic superposition Can be stacked simultaneously99 types of harmonics

Harmonic mode fundamental wave @ 50Hz Inject 2-100% harmonic content

可编程双向交流源载系统

Screenshot of power analyzer

Built in advanced features 30 types of harmonic voltage waveforms Convenient for users to call with just one click.

可编程双向交流源载系统

built-in 30 types of harmonic voltages

可编程双向交流源载系统

Interharmonic mode interharmoniccontent 10% , frequency@Starting from 200Hz, over 600Hz

5.5 waveform editing

Built in multiple types of waveforms Like triangular waves square wave Clipping wave trapezoidal wave Sawtooth wave and other waveforms Users can access it through the upper computer or the menu

Monotonic use and in LCD The selected waveform is displayed on the screen.

可编程双向交流源载系统

triangle wave@Phase A 220V Symmetry degree 50%可编程双向交流源载系统

square wave@Phase A 220V, duty cycle 50%

可编程双向交流源载系统

sawtooth wave@Phase A 220V

可编程双向交流源载系统

Phase A 220V, Clipping wave 15%

可编程双向交流源载系统

trapezoidal wavePhase A 220V Rise time 20% , descent time 20%

5.6 Harmonic display

Harmonic analysis function Including voltage harmonic measurement and current harmonic measurement . Voltage and current harmonic distortion factors can be achieved in harmonic mode

THD Phase difference test of harmonic on fundamental wave . In addition, multiple harmonic measurements can be conducted Display the results in a list format Analyze the test results More clear at a glance.

可编程双向交流源载系统

fundamental wave@50Hz , 10-15 harmonic notes

5.7 Feedback based communication load

5.7.1 Universal communication load

Universal communication load function support CRThe CCThe CP Multiple output modes Open functionRate factor Peak factor setting through List Programming pre Set up multiple combinations of work steps Implement dynamic loading.

可编程双向交流源载系统

Universal communication load mode

Open active power P、 Reactive power QL Capacitive reactive power QC Parameter Settings Simulate multiple load output characteristics.

可编程双向交流源载系统

PQ pattern

5.7.2 RLCload

RLC Communication load function built-in R、 RLThe RC Waiting up to 14 types RLC network model Flexible adjustable parameter moduleQuasi load characteristics for inverter Test of anti islanding protection characteristics for energy storage inverters And verify the performance of the tested component under different load impedance modes.

RLC load mode

可编程双向交流源载系统

6、 Product appearance

6.1 Single machine

可编程双向交流源载系统

6.2 Parallel operation

可编程双向交流源载系统