Welcome Customer !

Membership

Help

Shanghai Chemical Research Institute Co., Ltd. (Shanghai Tanlian Chemical Technology)
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Chemical Research Institute Co., Ltd. (Shanghai Tanlian Chemical Technology)

  • E-mail

  • Phone

  • Address

    No. 345 Yunling East Road, Putuo District, Shanghai

Contact Now

Price of IR600 series multi-component infrared gas analyzer

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The IR600 series multi-component infrared gas analyzer is designed for continuous gas concentration measurement in industry and laboratory, suitable for various gas detection, as well as special gas detection formed in production and processing. Based on the principle of infrared absorption, the gas detection module not only has good selectivity for the measured gas, but also can measure gas concentration with high precision and stability. This module has a compact structure and extremely low maintenance costs, making it suitable for very harsh application environments.

Product Details

Price of IR600 series multi-component infrared gas analyzer

·The IR600 series instruments are designed for continuous gas concentration measurement in industry and laboratories, suitable for various gas detection, as well as special gas detection formed in production and processing.

·Based on the principle of infrared absorption, the gas detection module not only has good selectivity for the measured gas, but also can measure gas concentration with high precision and stability.

·This module has a compact structure and extremely low maintenance costs, making it suitable for very harsh application environments.
Price and technical indicators of IR600 series multi-component infrared gas analyzer:

测量组份: CO、CO2、CH4、 NH3、SO2、NO、SF6、C2H2、C4H10、C2H4、C3H8、R22、R123、R125、R134A、R404A、R290、R600、R744

Measurement range: Trace: 0-5000ppm, Constant: 0-100%

Response time (T90): approximately 15 seconds (@ 0.5 L/min)

Detection principle: Non dispersive infrared (NDIR)

Detection limit: ≤ 1% FS

Preheating time: 2 minutes

External trachea size: inner diameter 4mm, outer diameter 6mm

External gas pipe type: stainless steel pipe, copper pipe or fluororubber gas pipe

Operating temperature: 5 ℃~45 ℃

Storage temperature: -25 ℃~70 ℃

Environmental humidity: relative humidity 0% to 95%, non condensing

Work pressure: 30KPa~100KPa

Working flow rate: 0.5-1.5 L/min Stable flow rate

Analog output: 4-20 mA standard signal

Working voltage: 220VAC