AGELA Integrated Solution for Separation and Purification
HS-D-5800PPreparation type high-pressure liquid chromatography system
The newly launched modular 40Mpa high-pressure purification system solution is stable and worry free, easy to use, and can be freely prepared
The development of purification methods has broad boundaries
stable and reliable
Agela HS-D-5800P 40MpaPreparation type high-pressure liquid chromatography systemAdopting a dual plunger parallel solution transfer unit for chromatography
The experiment provides higher flow accuracy and repeatability. Durable accessories are used to enhance the stability of laboratory personnel for extended periods of time
Confidence in complex sample preparation and overnight preparation.
▲ Multi point flow correction curve to ensure flow accuracy from low flow rate to high flow rate range.
The floating plunger design improves the service life and flow stability of the pump, and effectively extends the service life of the high-pressure sealing ring. branch
Manually clean the plunger and plunger sealing ring to prevent the sealing ring from shortening its service life due to the crystallization of high salt concentration buffer solution.

Figure 1 shows that HS-D-5800P can accurately mix the mobile phase in the set ratio with high gradient accuracy to ensure the accurate implementation of the preparation method
Agela HS-D-5800P 40MpaPreparation type high-pressure liquid chromatography systemEquipped with an automated high-precision automatic sampler,
Specially designed for experimental preparation, while meeting the requirements of high-throughput sample loading capacity, greater emphasis is placed on the stability and reliability of the design.
▲ Ultra low sample residue effectively reduces cross contamination.
▲ The injection requirements can be precisely defined, and the injection volume has good accuracy and repeatability.

Figure 2: Linear correlation coefficient between different injection volumes and peak areas tested using naphthalene methanol solvent as a sample
Easy to use at will
Agela HS-D-5800P 40MpaPreparation type high-pressure liquid chromatography systemEquipped with a software system designed specifically for intelligent and automated preparation requirements, it meets advanced requirements and personalized usage habits such as complex multi-level gradients and different collection modes in preparation experiments.
In order to meet the processing capacity of high-throughput samples, HS-D-5800P has made significant optimizations and improvements in sample disk capacity, and pays more attention to customer experience and convenience in method settings. In the software, different specifications of the automatic sampler test tube rack can be freely switched. The left large volume sample tube holder can accommodate 40 mL sample bottles, and with pre cut bottle cap pads, it can effectively reduce the evaporation of sample solvents. The fraction collection interface allows for the selection of various sizes of collection tubes, and the horizontal or vertical S-shaped collection direction can be chosen according to usage habits. Five collection disk positions are more suitable for high-throughput preparation experiments. The fraction collector can enable fixed-point repeated collection function, combined with the stacking injection function, which can collect the same fraction obtained from multiple stacking injections in the same test tube.
Gradient method editing
Multi level gradient editing for complex sample preparation has always been a pain point for experimental personnel, and the HS-D-5800P software has been optimized specifically for this pain point.
▲ Supports the setting and direct calling of general multi-level gradient methods, greatly saving program setup time.
After calling the general method, it can be edited and fine tuned again in the running interface. Rich editable method fields can also be customized to hide infrequently used fields, making the interface more concise and clear.
The table area supports one click insertion, online drag and drop adjustment, and editing functions to add gradient points. It can also switch between preset condition collection and manual collection with one click, bidding farewell to lengthy and complex operations.
▲ Supports loop (overlay) injection function and fixed-point (repeat) collection function.
The software logic has been verified and tested by industry experts, and can be quickly used without additional learning costs.
Multiple collection modes
HS-D-5800P not only supports basic manual collection, automatic full collection, window collection and other modes, but also supports optional ELSD detector for collection determination and monitoring. It can also be determined simultaneously with UV, and supports peak collection and automatic determination of slope peak cutting, ensuring the purity and recovery rate of fractions.
Overlay injection function
Agela designed a stacked injection function for customers in the injection module and software collection to achieve continuous preparation in the face of repeated injection of a single sample. For samples with large sample volume or requiring repeated preparation with small injection volume, it is convenient to set the number of superimposed injection needles.
Equipped with an automatic suction sampler, the same sample can be accurately injected continuously and repeatedly. Due to the ability to perform continuous preparation operations, samples with large liquid volumes can also be easily and efficiently purified.
Instrument: HS-D-5800P
色谱柱: Venusil MP C18, 5 μm, 100 Å
Specification: 21.2 × 250 mm
Item number: VA952520-0
Mobile phase: water: acetonitrile=20:80
Flow rate: 16 mL/min
Wavelength: 254 nm (red signal line)
280 nm (blue signal line)
The samples are toluene and naphthalene (2 mg/mL each, dissolved in methanol: water=7:3)
Injection volume: 1 mL Injection interval of 4 minutes
40Mpa pressure resistance
The HS-D-5800P achieves a pressure resistance of 40Mpa through a more stable pump head structure design. Higher system pressure resistance can support you to confidently choose smaller particle size preparation columns or develop multi column series preparation methods, or increase flow rate and pressure for faster preparation.
Ordering information:

-----------------------