- Phone
-
Address
No. 5500 Yuanjiang Road, Minhang Economic Development Zone, Shanghai
Shanghai Haoyun Instrument Equipment Co., Ltd
No. 5500 Yuanjiang Road, Minhang Economic Development Zone, Shanghai
| 006SCC-10-40-AF | SOLVENTPLUS COLUMN 10MM/400MM 1xF 1xA |
| 006SCC-10-40-FF | SOLVENTPLUS COLUMN 10MM/400MM 2xF |
| 006SCC-10-50-AA | SOLVENTPLUS COLUMN 10MM/500MM 2xA |
| 006SCC-10-50-AF | SOLVENTPLUS COLUMN 10MM/500MM 1xF 1xA |
| 006SCC-10-50-FF | SOLVENTPLUS COLUMN 10MM/500MM 2xF |
| 006SCC-15-10-AA | SOLVENTPLUS COLUMN 15MM/100MM 2xA |
| 006SCC-15-10-AF | SOLVENTPLUS COLUMN 15MM/100MM 1xF 1xA |
| 006SCC-15-10-FF | SOLVENTPLUS COLUMN 15MM/100MM 2xF |
| 006SCC-15-15-AA | SOLVENTPLUS COLUMN 15MM/150MM 2xA |
| 006SCC-15-15-AF | SOLVENTPLUS COLUMN 15MM/150MM 1xF 1xA |
| 006SCC-15-15-FF | SOLVENTPLUS COLUMN 15MM/150MM 2xF |
| 006SCC-15-25-AA | SOLVENTPLUS COLUMN 15MM/250MM 2xA |
| 006SCC-15-25-AF | SOLVENTPLUS COLUMN 15MM/250MM 1xF 1xA |
| 006SCC-15-25-FF | SOLVENTPLUS COLUMN 15MM/250MM 2xF |
| 006SCC-15-40-AA | SOLVENTPLUS COLUMN 15MM/400MM 2xA |
| 006SCC-15-40-AF | SOLVENTPLUS COLUMN 15MM/400MM 1xF 1xA |
| 006SCC-15-40-FF | SOLVENTPLUS COLUMN 15MM/400MM 2xF |
| 006SCC-15-50-AA | SOLVENTPLUS COLUMN 15MM/500MM 2xA |
| 006SCC-15-50-AF | SOLVENTPLUS COLUMN 15MM/500MM 1xF 1xA |
| 006SCC-15-50-FF | SOLVENTPLUS COLUMN 15MM/500MM 2xF |
| 006SCC-25-10-AA | SOLVENTPLUS COLUMN 25MM/100MM 2xA |
Whole column
Each column is assembled for use, and can be connected to existing systems by connecting pipes and pipe joint filters (10um). The following columns are also provided:
Fixed height pillar
When there is no need to adjust the length of the column, it is more economical to have both ends fixed.
Adjustable height column
By using an adjustable piston on one end, the range of 80mm can be adjusted, and the length can be easily adjusted to avoid affecting the filling material.
Standard liquid phase system
fromBorosilicate glass, polytetrafluoroethylene(The column body made of PTFE and the sealed column made of polyethylene filter (25um) can be used in many fields.
Anti solvent effect system
Just take itReplacing the filter made of polyethylene (PE) at both ends with PTFE filter (included in the accessories) can make the entire system an inert system, which can be applied to highly corrosive chemical solvents.
Column pipe joint
All columns provided to users are equipped with pipe fittings that can be directly used at both ends, and 1/4-28UNF is the standard interface size with two blue hats on both sides.
Replaceable accessories
The glass column and the joint filter at both ends, as well as the fixing ring, can be replaced.