Portable water quality heavy metal rapid detector
Adopting electrochemical rapid detection method---Anodic stripping voltammetry,Combining national standard methods---Photometric colorimetry,It can be applied to on-site emergency detection (such as emergency monitoring of water pollution accidents), as well as heavy metal detection and analysis in laboratories. It is suitable for environmental protection bureaus, water management bureaus, monitoring stations, water companies, and disease control centers, and can be used for monitoring surface water, groundwater, seawater, industrial wastewater, drinking water, or other environmental water bodies.
the productScalable measurement of indicators such as hexavalent chromium, nickel, manganese, etc. Can meet the needs of environmental monitoring agencies at all levels, environmental science institutes, universities, water treatment plantsOn site rapid detection of heavy metals in water quality by enterprises and others
Portable water quality heavy metal rapid detector
Main technical parameters:
project |
maintechnologyparameter |
measurement parameters |
Copper, cadmium, lead, zinc, arsenic, mercuryMore than ten heavy metal parameters such as manganese, antimony, nickel, etc. (can be expanded to measure more parameters)) |
Testing Scope |
Dissolution voltammetry:0.1Mg/L~Dozensmg/L colorimetry:0.01mg/L~5mg/L(Developed copper, chromium, nickel, lead, zinc, iron, cobalt, manganese, etc.)) Note: The detection range of different elements may vary slightly |
repetitiveness |
RSD≤2%(With)Cd 50Mg/LCalculation) |
indication error |
≤±10% |
detection limit |
≤0.5Mg/L |
Application case: Surface wateron-siteactualtest
water samplebasebody:取someSeveral actual water samples along the riverbank
testMethod: Take actual water samples as the basebody, respectivelyadda certain amount ofleadCadmium, mercurysixpriceChromium standardliquid(Each type)metal ionprepare, compound, formulateThe concentration is50ug/L),useinstrumentUnited Statesanodedissolution,Corresponding measurement of lead, cadmium, and mercury)Modules and Colorimetrymodule(Corresponding toMeasure hexavalent chromium)respectivelyMeasurement, yesConduct spiked recovery rate testing on actual water samples.
serial number |
testproject |
marking50ug/Lmeasurementresult |
|||
markingfront |
markingafter |
Recycling value |
Spiked recovery rate(%) |
||
1 |
lead |
0.02 |
50.3 |
50.2 |
100.4 |
2 |
cadmium |
0.05 |
49.6 |
49.5 |
99.0 |
3 |
zinc |
69.6 |
122.5 |
52.9 |
105.8 |
4 |
mercury |
0.17 |
48.9 |
48.7 |
97.4 |
5 |
hexavalent chromium |
0.03 |
49.8 |
49.7 |
99.4 |
to the aboveAdd standard sample(100ug/L)respectivelyDetermination by plasma mass spectrometryleadCadmium,flameAtomic absorption method measurementZinc,The atomic fluorescence method is used to determine mercury, and the spectrophotometer method is used to determine hexavalent chromium. The measurement results are as follows:
serial number |
testproject |
thatinstrument |
laboratoryinstrument |
||
Recycling value |
markingrecovery rate(%) |
Recycling value |
Spiked recovery rate(%) |
||
1 |
lead |
101.3 |
101.3 |
101.5 |
101.5 |
2 |
cadmium |
98.8 |
98.8 |
99.2 |
99.2 |
3 |
zinc |
100.5 |
100.5 |
98.8 |
98.8 |
4 |
mercury |
96.9 |
96.9 |
104.0 |
104.0 |
5 |
hexavalent chromium |
98.5 |
98.5 |
102.8 |
102.8 |
Conclusion:The portable water quality heavy metal analyzer has the characteristics of small size, easy portability, simple pretreatment, low detection limit, high detection accuracy, and fast detection speed. The test results have a good correlation with laboratory instrument methods and can be easily portable for outdoor on-site environmental emergency monitoring.