Welcome Customer !

Membership

Help

Shanghai Tawang Intelligent Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Tawang Intelligent Technology Co., Ltd

  • E-mail

    info@tow-int.net

  • Phone

    15221725700

  • Address

    Building 2, No. 351 Sizhuan Road, Sijing Town, Songjiang District, Shanghai

Contact Now

Portable respiratory metabolism measuring instrument

NegotiableUpdate on 01/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The portable respiratory metabolism measuring instrument is highly integrated with gas concentration measurement system, flow control system, and respiratory measurement system, achieving miniaturization and portable measurement while having the same function as the respiratory heat metabolism detection system. Using indirect calorimetry to measure human energy metabolism. The main indicators include basal metabolic rate, resting metabolic rate, predicted metabolic rate, respiratory rate, oxygen consumption, CO ₂ production, and the proportion of consumption of the three major nutrients. $r $n $r $n During the measurement, the subject carries a portable respiratory metabolism meter on their back with a harness and wears a face mask, which can measure the energy metabolism of the human body in a state of free movement.
Product Details

Product description

Portable respiratory metabolism measuring instrumentHighly integrated gas concentration measurement system, flow control system, and respiratory measurement system, achieving miniaturized and portable measurement while having the same functionality as respiratory heat metabolism detection system. Using indirect calorimetry to measure human energy metabolism. The main indicators areBasal metabolic rateResting metabolic ratePredicting metabolic ratebreathefrequencyrateOxygen consumptionCOProduction volume, consumption ratio of the three major nutrients, etc.

During the measurement, the subject will carry it with a harnessPortable respiratory metabolism measuring instrumentCarrying it on the body and wearing a face mask can measure the energy metabolism of the human body in a state of free movement.

Product Features

1. Highly integrated

Integrated gas analysis module, flow control module, and respiratory measurement module

Fully functional, suitable for measuring resting metabolism and exercise metabolism

High precision, high sensitivity, fast response

2. Convenient and easy to use

Fully automatic calibration program

One click start

3. Compact and portable

A pack of tissue sized tissues, easy to carry

Waterproof and dustproof, suitable for outdoor use

4. Flexible and scalable

haveIndependent control and data processing system, can be used independently

Data can also be wirelessly transmitted to a computer for viewing and analysis

It can also be connected to a computer through a wired connection and controlled by computer software

Technical Specifications

1. Gold standard method: indirect calorimetry for evaluating human respiratory metabolism levels;

2. Monitoring indicators: oxygen concentration, carbon dioxide concentration, temperature, humidity, oxygen uptake, CO ₂ production, metabolic rate (EE), respiratory quotient (RQ), consumption and consumption ratio of major nutrients, heart rate, blood oxygen saturation, maximum oxygen consumption (VO ₂ max);

3. Test modes: Resting hood, face mask mode, ventilator mode;

4. Integrated: A portable integrated device that, although small, has all five components and can be used independently;

5. Multi functional and expandable: It can be wirelessly connected to a computer, and can also be connected to a computer with a data cable for more comprehensive testing and data analysis;

6. New generation Bluetooth: frequency range of 2.400GHz-2.48GHz, high-speed, stable, and anti-interference;

7. LoRa function: capable of long-distance communication and data transmission, suitable for outdoor sports scenes;

8. GPS function: real-time outdoor positioning;

9. Oxygen sensor: range: 19-21%, accuracy: 0.01%, resolution: 0.01%;

10. Carbon dioxide sensor: Infrared carbon dioxide sensor, range: 0-5.5%, accuracy: 0.03%, resolution: 0.01%.


Application field

1. Guidance and evaluation of exercise training program: metabolic assessment under free exercise state

2. Weight loss and exercise program guidance and effectiveness evaluation: sports medicine, body shape management

3. Clinical nutritional assessment and support: Nutrition, Oncology, Geriatrics

4. Disease assessment and personalized treatment plan guidance: Oncology, Burns, Endocrinology, Intensive Care

5. Personalized dietary plan: high uric acid, high blood sugar, high blood lipids




*Our company can provide 3Q verification, customize functions according to customers' special applications and needs, and also provide related experimental services. Please contact us for details.

*This introduction and parameters are basic product information and may lag behind product updates,Please contact our company for specific parameters.