Portable pH/ORP analyzer (handheld controller)

NegotiableUpdate on 02/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The portable pH/ORP analyzer (handheld controller) CAMH-PH is used to measure the pH and ORP concentration of open industrial water, sewage, etc. The sensor supports continuous monitoring and has a built-in temperature sensor. Compact design, easy installation, and reliable operation. A single sensor supports both analog and digital output. The $r $n sensor is mainly used in urban pipeline networks and aquaculture industries.
Product Details


Portable pH/ORP analyzer (handheld controller)CAMH-PHIt is an analyzer that uses electrode method for measurement. When measuring, users only need to put the sensor into the water sample to be tested, and the numerical value of ion concentration can be directly read. The sensor has a built-in temperature sensor (NTC) that can perform real-time data compensation.

Portable pH/ORP analyzer (handheld controller)CAMH-PHIt can be directly connected to the control unit. The sensor is packaged in ABS and has a built-in temperature unit for compensating the measured values. The sensor has a compact design, low power consumption, and customizable cable length.

Portable ion analyzer CAMH-PHSimultaneously providing wide range measurement. In addition, the sensor is waterproof and supports immersion in water, making it very suitable for agriculture, sewage measurement, or other environmental measurement fields.


1) Before using the sensor, please shake it vertically in the air to ensure that there is no air residue on the ion electrode head.

2) Sensors should be placed in larger containers for long-term testing. Before client testing, please soak the sensor in clean water and replace it with clean water 2-3 times to ensure that there is no potassium ion residue on the surface of the pH electrode.

3) When the sensor is in use or left out of water for more than 30 minutes, please place the sensor in the water sample and let it stand for more than 60 minutes. After the value stabilizes, read the value. Economically reliable:

-No sample pretreatment is required, and ammonia nitrogen and nitrate nitrogen can be measured directly.

-PH measurement is standard - no reagents required, low cost of use - flexible to use, with a wide range of applications:

-Wide range: 0.1-1000 mg/l NH4-N or 0.5-1000 mg/l NO3-N - Easy to operate and safe:

-Directly installed by the pool without the need for a liquid collector or sample transfer pump

-Replacing the laminated cap every 6 months effectively extends the service life of the electrode. Standardized digital communication is plug and play

CAMH-DOThe handheld controller does not involve numerical calculations, and the calculation process is performed internally within the digital sensor;

If the controller prompts low battery, please charge it before use, as low voltage can cause damage to the sensor.

Pay attention to waterproofing of sensor connectors.

Please unplug the sensor from the controller when not in use. Otherwise, it will still consume battery energy and reduce battery usage time.