E-mail
674338455@qq.com
-
Phone
18611900152
-
Address
18 Qinghe Anningzhuang East Road, Haidian District, Beijing
Beijing Beidouxing Technology Co., Ltd
674338455@qq.com
18611900152
18 Qinghe Anningzhuang East Road, Haidian District, Beijing
HBD5OMC2290Portable oil mist detectorFeatures:
1. Built in microcontroller microcomputer
2. Simply insert the sample at any temperatureRead the concentration value immediately
3. 24 sets of data records, can be set to automatic or manual recording
4. Readable/Print records
5. Can be used for grinding bottles, or temporary continuous analysis of pipelines
6. RS232/485 duplex interface, capable of online sampling with microcomputers
7. Zero adjustment of inert gasCalibration of standard samples or substitutes
8. All operation keyboard settingsWindow prompt
9. All data can be saved in case of power failure
10. Can refresh the program
11. Can provide full range testing, saving the trouble of range selection
12. Can quantify the concentration of pure gases while providing8 calibration tables are available for users to create calibration data for gases without a database provided.
13. Built in quantification database for hundreds of common gas concentrations, andTwin toxic gas safety protection standards or hazardous gas explosion limits, users can calibrate and set alarm limits
14. The Beidouxing handheld sensor is ingeniously designed to be similar to general instruments, directly used for grinding bottles, or connected to pipelines with pipe threads for temporary continuous detection.
15. You can use the keyboard to select the type of gas to be tested.
HBD5OMC2290Portable oil mist detectorapplicationApplication:Air background oil mist concentration test;金属切削Cutting fluid oil mist commonly used in CNC machining;Oil mist testing for industries such as metal cutting fluid, metal polishing, metal forming, mold manufacturing, heat treatment, cleaning agents, etc.
Detection of Mineral Oil Mist Concentration in Air Background
Mineral oil mist concentration detection in the following gases: N2、O2、CO2、H2O, CO、HCN、SO2, Natural gas (methane, ethane, propane), acidic gases (HCL, HF, HNO3), fluorocarbons, ozone.
Other background gas tests require specialized consultation.
|
display Tool:2×16 LCD Response time:< 1ms Ambient temperature-30 ℃~70 ℃ (processor) ambient humidity:0% to 90% R (processor) |
Power Supply:9V rechargeable battery Continuous operation of battery:>10 hours/pressure drop alarm Processor size:98W×180H×35D Analyzer resolution24 bits (FS=+/-1280mV) |
Specification and technical parameters of oil mist sensor:
ND |
diffusion |
optional |
ND+Wxm |
immersive |
Combination of diffusion and cable to form an input typeConvenient locations that are out of reach of testing personnel; X represents the number of meters of wire to be ordered; |
SP |
Pump suction sampling |
|
SP+Pxm |
Guided type |
Combination of trachea and pumpGas from inaccessible locations can be drawn in for testing; X represents how many meters of pipes need to be ordered; |
Model of oil mist sensor:
model |
106AH |
|
Minimum detection limit |
5ppb (based on isobutene as a reference, suitable for quantifying mineral oil mist concentration) 2.55ppb (using toluene as a reference, suitable for quantifying the concentration of vegetable/animal oil mist) |
|
Linear range |
50ppm (based on isobutene as a reference, suitable for quantifying mineral oil mist concentration) 25.5 ppm (based on toluene as a reference, suitable for quantifying the concentration of vegetable/animal oil mist) |
|
Maximum test value |
1000 ppm (based on isobutene as a reference, suitable for quantifying mineral oil mist concentration) 510ppm (based on toluene as a reference, suitable for quantifying the concentration of vegetable/animal oil mist) |
|
repeatability accuracy |
± 1% FS, or ± 3% reading, whichever is greater |
|
warm-up time/Minutes |
15 |
|
Operating temperature |
-40~+40ºC,max to 60ºC |
|
Use humidity |
0-90%, no condensation |
|
response time/Second |
<3 |
|
safety indicators |
IECEx Ex ia IIC T4; ATEX EEx ia II 1G -40ºC <Ta <+40ºC |
|
Service life of light bulb |
>18 months (continuous time) |