HBD5gas2610-HCNhandheldHydrogen cyanide gas detector
Instrument features:
Built in microcontroller microcomputer
Equipped with selective sensorsSimultaneously test the temperature for temperature correction
Simply insert the sample at any temperatureImmediately read out the electrochemical gas parameters and temperature values
Sound and light alarm function, alarm limit can be set, solidification hasTLV, STEL alarm database
24 sets of data records, can be set to automatic or manual recording
Readable/Print records
Can be used for grinding bottles, or temporary continuous analysis of pipelines
RS232/485 duplex interface, capable of online sampling with microcomputers
Zero adjustment of inert gasCalibration of standard samples or substitutes
Supports two-phase analysis and can test dissolved gases
Multi meter calibration, supporting cross testing of multiple gases
All operation keyboard settingsWindow prompt
The Beidouxing handheld sensor is ingeniously designed to be similar to general instruments, directly used for grinding bottles, or connected to pipelines with pipe threads for temporary continuous detection.
The H-BD5gs analyzer also supports cross gas single gas testing. That is to say, it can also be used for testing other gases in addition to the main gas being tested. Provide information on other measurable gases in the product documentation.
lLaboratory or on-site simple gas analysis testing
lThe electrode can be usedZG1 "pipe thread can be inserted into the pipe for continuous detection, and can also be inserted into a grinding bottle
lGas research
lpollution source/Research on the regularity of emission outlets
lEnvironmental Monitoring
lProduction safety monitoring
ldisplay Tool:2×16 LCD
lAnalyzer resolution24 bits (FS=+/-1280mV)
lSensor response time:< 10s,Max<60s
lAmbient temperature-30 ℃~70 ℃ (processor)
lambient humidity:0% to 90% R (processor)
lPower Supply:9V rechargeable battery or DC 9V power supply
lContinuous operation of battery:>10 hours/pressure drop alarm
lProcessor size:98W×180H×35D
lThe lower limit of temperature for general electrochemical sensors is-10°C. Upper limit of 40 or 50°C。
lSafety level: intrinsic safety type
lChassis standard:IP10
General technical requirements for gas detection and alarm devices in work environments GB 12358-90
Insert the sensor into a plastic bag or container, place the measured gas inside, seal the bag opening to a certain extent, and maintainOne minute reading is sufficient.
Other standard sampling methods are also acceptable, but the sensor must be kept at atmospheric pressure or belowTested under 10% conditions.
model |
parameter |
Application and cross interference information |
|||
hydrogen cyanide |
HBD5gs-HCN-R30 |
0.3-30ppm |
Cross interferenceNO<-5%; NO2<-70%; |
||
hydrogen cyanide |
HBD5gs-2ph-HCN-R30 |
gas phase:0.3-30ppm; aqueous phase: 0-100ug/kg @25°C |
Cross interferenceNO<-5%; NO2<-70%; |
*Other liquid dissolved gas analysis requires self calibration;
Users can configure according to their needsExplain your specific application, which will help our engineers recommend the most suitable detector to you.
Beidou Satellite Instrument Handheld Toxic and Harmful Gas Detector, Portable Harmful Gas Detection Alarm DeviceSome conventional detectable gases:Oxygen O2, combustible gas Ex, carbon monoxide CO, hydrogen sulfide H2S, nitrogen dioxide NO2, nitrogen monoxide NO, chlorine gas Cl2, ammonia gas NH3, hydrogen gas H2Hydrogen green acidHCN、 Ozone O3, fluorine gas F2, hydrogen fluoride HF, hydrogen chloride HCL, hydrogen bromide HBr, ethylene oxide C2H4O, refrigerant R134A, phosgene COCL2, silane SiH4, germane GeH4, arsine AsH3, chlorine dioxide ClO2, nitrogen tetrahydrogen N2H4EthylcyclohexaneB2H6、 ammoniaNH3、 Hydrogen H2, methane CH4, and so on. Welcome to purchase!