Triathler LSCPortable liquid scintillation counter
1Diverse functions
HidexTranslate into EnglishalphaTheB、γAnd chemiluminescenceL(Luminescence)Three detection functional components“module”Closely combined in various ways“Triathlon detector”(Triather)Can be implemented separately“One instrument, three uses”At the same time, it can also interact withHPLCConnect and use drugs labeled with low-energy isotopesHPLCSeparation, entryTriathlerThe testing laboratory obtains the corresponding drug activity, providing an application platform for the development and clinical diagnosis of radiopharmaceuticals.
2、 Good compatibility
Through the adapter,TriathlerUse sample bottles of various models and sizes, includingEppendorfGlass or plastic measuring bottles of different specifications.TriathlerCan easily convert various types(alphaTheB、γAnd chemiluminescenceL)Detection method.
a、 Multi channel analysis(MCA):TriathlerAdopting a multi-channel analyzer that is rarely used in similar domestic instruments(MCA)To achieve online real-time monitoring of the spectral shape and activity of samples, it provides the possibility for nuclide identification and continuous dynamic monitoring of short half-life samples.
bThea/bIdentification:Triathlerseparablea/bCount the nuclides and provide the best value.
c、 directDMPTechnology: MostBNuclide(3HThe14CThe32PWait, you can directly obtain itDpmNumber without quenching the standard source.
3The software is simple and easy to use
aTheComn,FilerIIApplication software based onWindows平台和ExcelThe sample data can be transmitted to a computer for data processing and graphical display.
b、 directDMPTechnology: MostBNuclide(3HThe14CThe32PWait, you can directly obtain itDpmNumber without quenching the standard source.
4Small and compact in size
“Triathlon detector”The external dimensions are only190*250*330mmNet weight only9KgIt can be placed in a suitcase and is suitable for outdoor work.
5、 Easy to maintain
“Mode block”Components provide great convenience for instrument maintenance and create conditions for remote maintenance required by customers.
Triathler LSCPortable liquid scintillation counterApplication:
● Tritium wiping test
● Radiochemistry
● molecular biology
● biotechnology
● Triphosphate monitoring
● Life Science Research
● environmental monitoring
● radiation safety