Hitachi Aloka high-efficiency liquid scintillation counter

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

LSC-8000 is a new generation liquid scintillation measuring instrument developed by Hitachi Aloka, and also the 15th generation liquid scintillation measuring instrument of Hitachi Aloka. In Japan, Hitachi Aloka's liquid scintillation series has long been used as products by the Japanese Ministry of Education, Culture, Sports, Science and Technology's tritium analysis method and liquid scintillation radioactive nuclide measurement analysis method.

Product Details

1. Hitachi Aloka high-efficiency liquid scintillation counterProduct Overview

LSC-8000 is a new generation liquid scintillation measuring instrument developed by Hitachi Aloka, and also the 15th generation liquid scintillation measuring instrument of Hitachi Aloka. In Japan, Hitachi Aloka's liquid scintillation series has long been used as products by the Japanese Ministry of Education, Culture, Sports, Science and Technology's tritium analysis method and liquid scintillation radioactive nuclide measurement analysis method.

Hitachi Aloka high-efficiency liquid scintillation counter

2.Product Technical Parameters

Basic Performance

3The counting efficiency of H is over 60%,14The counting efficiency of C is over 95%

background value

3H: Below about 8ppm;14C: Less than 5 CPM (20ml plastic scintillation bottle, measured data from ALOKA factory)

resolution

Tritium analysis can reach up to 0.005KeV/ch

Measure the sample

Corresponding to various sample bottles ranging from 1.5ml centrifuge tubes to 20ml standard

FM value

3H: 180 or above;14C: 400 or above; FM value: Figure of Merit value. An indicator that represents the performance of the detection lower limit of a low background liquid scintillation measurement system.

sample size

408 (standard, small sample bottles) * Small sample bottles require a converter

number of users

50

Operation screen

10.4-inch color touch screen

Dual language display

Chinese, English (Japanese, French can also be selected)

Quenching correction

ESCR method (external source irradiation method), SCCR method (self standard method), ETM (extrapolation method), automatic identification of nuclides

Sample exchange method

Lack mode of carrier

analytical method

Two photomultiplier tubes (PMT) are used for high-resolution spectral analysis through gain switching of a 4000ch multi-channel analyzer

Analysis Window

3 windows

Built in measurable nuclide window

3H、3H-LOW、14C、14C-LOW、32P、32P(Cer.)、125I、3H+14C、3H+14C+32P

Can set measurement time

0.1 ~ 9999.9 min

Can set measurement count

1 to 9999999 times

number of repetitions

1 ~100

number of cycles

1 ~100

External output interface

RS-232C,LAN,USB

Environmental temperature and humidity for use

5-35 ℃, 30-80% (no frost)

power supply

AC100V~240V, 50/60Hz approximately AC200V

Overall dimensions

Approximately 96 (W) × 85 (D) × 60 (H) cm

weight

About 196kg