Welcome Customer !

Membership

Help

Shaanxi Fusaisi Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shaanxi Fusaisi Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    New City Science and Technology Industrial Park, Xincheng District, Xi'an City

Contact Now

Portable infrared oil concentration analyzer (infrared oil analyzer)

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Beidou Star Instrument p-LLA4160_OCA portable infrared oil concentration analyzer (infrared oil analyzer) is a professional organic component infrared spectral absorption analyzer designed based on the principle of photometry. It identifies types through scanning spectrum analysis and tests concentration through transmittance. Perform rapid analysis on extraction. $r $np-LLA4160OCA Auto is a fully automatic water oil analyzer. Simply insert the sampling tube into the water sample and press Analysis Press the 'gt' button, and the system will automatically extract and analyze the water sample. Support direct analysis, which means analyzing externally prepared extraction solutions

Product Details

p-LLA4160_OCAPortable infrared oil concentration analyzer (infrared oil analyzer)Principle Introduction:

p-LLA4160'OCA is a professional organic component infrared spectroscopy absorption analyzer designed based on the principle of photometry. It identifies types by scanning spectra and tests concentration through transmittance. Perform rapid analysis on extraction.

P-LLA4160'OCA Auto is a fully automatic water oil analyzer. Simply insert the sampling tube into the water sample, press the<Analysis>or<Continuous Analysis>button, and the system will automatically extract and analyze the water sample. Support direct analysis, which means analyzing externally prepared extraction solutions.

This instrument is a fixed purpose analysis system designed for the analysis of oil concentration in water bodies. Suitable for monitoring the content of petroleum (mineral oil), animal and vegetable oils, and total oil in various water bodies and soils such as surface water, groundwater, seawater, domestic water, and industrial wastewater. It can also be used for standard sampling methods to support the monitoring of oil content in flue gas (cooking fumes in the catering industry). It can also be used for purity detection of organic reagents and measurement of the total amount and amount of organic compounds containing various C-H bonds.

Support standard methods:

Determination of petroleum and animal and vegetable oils - Infrared photometric method - GB/T 16488-1996


Infrared oil analyzer function:

Built in microcontroller microcomputer

Quickly detect parameters and temperature values, and perform temperature correction and cross correction

100 sets of data records, can be set to automatic or manual recording

RS232/485 duplex interface, capable of online sampling with microcomputers

Software zeroing, calibration of standard samples or substitutes

All operation keyboard settings, window prompts


Application of water oil detector:On site or laboratory water oil analysis

Application of portable oil analyzer:

Environmental Monitoring

Pollution source detection

On site analysis of industrial water quality

Scientific research laboratory analysis

Tester function:

On site LCD 4 × 16 character rotating display of multiple environmental parameters

Over limit alarm, alarm limit can be set

RS232/RS485 communication interface supports serial communication and can be connected to a computer

100 sets of data records. Readable, output or print

Pump sampling and sampling

Users can also calibrate or calibrate themselves

Portable infrared oil concentration analyzer (infrared oil analyzer)technical indicators:

BD7 host test ADC resolution: 1/60000;

Accuracy: ± 1-2% reading (general);

Long term stability:+/-10%/year (generally);

Analyzer response time:<10ms;

Probe response time:<1min;

Instrument usage environment: Temperature: -10 ℃ to 60 ℃; Humidity: 10% to 90% R (no condensation);

Instrument storage environment: temperature: 0 ℃~50 ℃; Humidity: 10% to 80% R (no condensation);

Electrochemical probe direct sampling: temperature: 0-40 ℃; Pressure:<1.1 kgf/cm2;

Power supply: 9V rechargeable battery with 220V AC charger:

Continuous usage time:>24 hours per charge; The battery should be stored for one week.

Detector technical parameters:

Scanning range: 3.0-4.1um; supports 2-band or 3-band analysis

Resolution: 0.1um;

Accuracy: ± 1% reading or ± 1% of full scale, whichever is greater

Dynamic range: 1:100/1000;

Range: LDLx (100~1000);

Electrical function and performance:

Please refer toBD4/BD5Smart transmitter/Introduction to Measurement and Control Devices;

Chassis packaging:NEMA 1 /IP10; NEMA 4 / IP56;

Chassis dimensions: W240*H132* D240/360;

Instrument quality assurance: 1 year;

Specification and model of portable infrared oil analyzer








Specification Model




Optical range


Testeable range








pLLA4160-TF3041-OCA




0.02-2.0mg/L


0.002-1000mg/L

pLLA4160-TF3041-OCA-Auto




0.02-2.0mg/L


0.002-20mg/L(Automatic Extraction)







20-1000 mg/L(Artificial extraction)