pAOM2290 portableIntroduction to compressed air oil and water content detector
Has the quality of compressed air oil and gas content reachedISO 8573 1 Level and0 Level qualified?
Using an oil-free compressor does not necessarily mean that your compressed air is oil-free, as the term“No oil pressureShrinking machine”It only refers to the compression chamber, not the entire compressor system, or the quality of compressed air produced.
The pollutants in compressed air systems can usually be attributed to:
lAir quality drawn into the compressor
lOperation of air compressor
lLubricant aging, volatilization, and leakage
lCompressed air storage equipment and distribution system
Rapid detection of compressed air oil and gas content
Most of the millions of particles in the normal urban ambient air inhaled by the compressor are belowThe aperture of the compressor inlet filter.
The hydrocarbons in the ambient air vary by region (usually including...) 0.05mg/m3 to 0.5mg/m3 The compressed air from sources such as automobile exhaust and industrial processes is often sufficient to pollute the system. Can the air handling system meet the requirement of oil-free air at all times?
Many industrial processes are highly sensitive to oil pollution, as it can lead to significant risks such as downtime, product deterioration and recalls, damage to company reputation, harm to consumer interests and product liability. Rapid measurement of pipeline oil content is of great significance.
AOM2290 Series air oil content detector
The HGA2290 series air oil detector adopts an ionization detector, which can be used for rapid or continuous detection of oil and gas content in compressed air and gas.
The simple installation and excellent performance make it an ideal choice for measuring and monitoring residual oil and gas content.
Oil free compressed air is not an easy task. In many industries and applications, monitoring is necessary to avoid product contamination and harm to human health.The HGA2290 series air oil content detector is economical, practical, and reliable.
In order to achieve good accuracy and long-term stability, the sensor will undergo automatic calibration. The system automatically checks for sensor contamination and sensor lifespan,And display the information to the user. Detection beyond the range will trigger an alarm and cut off the airflow to prevent contamination.
Always in compliance with ISO 8573“ CLASS 1 "and“ CLASS Rapid compliance verification of compressed air with oil and gas content of 0.
For facilities that always require clean air and no pollution, a continuous compressed air quality monitoring system is a necessary choice.
reference ISO 8573:2010 Part 2 + 5,HTM 02/01,HEDIS,NCQA certification 24/7, 1 level NFPA Medical compressed air system,GMP Professional requirements for facilities.
Common air oil vapor limit requirements(EN ISO8573-5)
1 Grade compressed air(EN ISO 8573-5):0.01 mg /m³
Medical applications(EAB 407/1238):0.1 mg/m³
Respirator(EN 12021):0.5 mg /m³
Portable compressed air oil and gas content detector pAOM2290 Purpose:
Quickly measure residual oil and gas content in compressed air and other gases
Only applicable to oil products with mineral oil as the base oil.
Compressed air, especially content measuring instrument function:
sceneLCD The data shows
Keyboard setting operation
audible and visual alarm
Application scope of compressed air quality detector:
*Medical air
*Pharmaceutical process
*Breathing air
*Ocean air
*Food and beverage industry
*Medical Engineering
*High speed train
*Semiconductor factory
*Food industry
*High tech process
*Electronic industry
*Aerospace
Portable compressed air oil and gas content detector pAOM2290Technical parameters:
technical indicators |
parameter |
| Low detection limit | 1 ppb (equivalent to 0.0041 mg/NM3 of toluene) |
Linear range |
Oil content:0.01ppm~40ppm; dew point:-80~20°℃ |
High test value |
40ppm |
Repetitive accuracy |
±3%FS |
warm-up time/Second |
5 |
Operating temperature |
-40~+55ºC,max to 65ºC |
Use humidity |
0-95%, no condensation |
response time/Second |
<3 |
safety indicators |
IECEx Ex ia IIC T4; ATEX Ex ia II 1G -40°C < Ta < +55ºC (< 10VDC supply) |
weather resistance |
IP10 |
pressThe compressed air oil and gas content detector is mainly used in the following industries: industrial manufacturing in industries such as steel, machinery manufacturing, rubber, batteries, cement, etc、Automotive Maintenance and Manufacturing、Medical and Dental、Construction and Mining、Food, pharmaceuticals, and chemicals、、Thermal power plants, thermal power plants, hydropower stations, and water treatment plants、Textile and Printing、Agriculture、Fire Protection and Emergency Response、Daily life and entertainment、navigationCompressed air quality testing, oil content testing, oil-water testing, compressed air and gas testing for aerospace (such as aircraft aerodynamic systems), electronics, papermaking, fertilizers, petrochemicals, etcResidual oil and gas content detection.