Portable grain and fruit fumigation gas detectorFeatures:
nBuilt in microcontroller microcomputer
nQuickly detect parameters and temperature values, and perform temperature correction and cross correction
n100Group data recording,Automatic or manual recording can be set
nRS232/485Duplex interface,Can be sampled online with a microcomputer
nInert gas software zeroing,Calibration of standard samples or substitutes
nAll operation keyboard settings,Window prompt
n10Priority identification and analysis of coexisting gases;
nScandynamic range100:1
nFinderdynamic range1000000:5,cross6Dynamic level concentration analysis
The p-Gas4160 portable gas detector is a professional gas analyzer designed based on the principle of photometry, which identifies gas types and test concentration ranges through scanning spectrum analysis.
Grain and fruit fumigation gas detection
Wood fumigation gas detection
Transport container fumigation gas detection
Other disinfection, sterilization, fumigation gas detection
Rapid gas analysis or online analysis
Environmental Monitoring
Pollution source detection
On site analysis of industrial processes
Scientific research laboratory analysis
non-siteLCD4 × 16 character rotating display of multiple environmental parameters
nOver limit alarm,Alarm limit can be set
nRS232/RS485The communication interface supports serial communication,Can be connected to a computer online
n100 sets of data records. Readable, output or print
nPump sampling and sampling
nUsers can also calibrate or calibrate themselves
lBD6 host test ADC resolution: 1/60000;
lAccuracy:±1-2% reading(average);
lLong term stability:+/-10%/year(average);
lAnalyzer response time:< 10ms;
lProbe response time:<1min ;
lInstrument usage environment: Temperature:-10℃~60℃; Humidity: 10~90%R(No condensation);
lInstrument storage environment: Temperature: 0℃~50℃; Humidity: 10~80%R(No condensation);
lElectrochemical probe direct sampling: temperature: 0-40 ℃; Pressure:<1.1 kgf/cm2;
lpower supply:6V rechargeable battery:
lContinuous usage time:>24 hours per charge; The battery should be stored for one week.
Detector technical parameters
scanning range:3.0-4.1um;
resolution:0.1um;
Accuracy:±1% reading or full scale±1%, whichever is greater
dynamic range:1:100/1000;
range:LDLx(100~1000);
Specification Model |
SO2 is smallLow detection limit LDL/1m |
SO2F2Minimum detection limit LDL/1m |
CH3BrMinimum detection limit LDL/1m |
PH3Minimum detection limit LDL/1m |
C2H4OMinimum detection limit LDL/1m |
CH4Minimum detection limit LDL/1m |
pGas4160-TF3041-OPL1m |
3ppm |
0.1ppm |
10ppm |
0.05ppm |
0.1ppm |
0.06ppm |
pGas4160-TF3041-OPL10m-FGA |
0.3ppm |
0.01ppm |
1.0ppm |
0.005ppm |
0.01ppm |
0.006ppm |
pGas4160-TF3041-OPL10cm |
30ppm |
1ppm |
100ppm |
0.5ppm |
1ppm |
0.6ppm |