Portable gas, dust, and smoke sampling deviceFlow calibrator model: H09280
Portable gas, dust, and smoke sampling device1、 Product Overview
This device integrates small flow, medium flow, and large flow calibration. It has high calibration accuracy, is easy to carry, and can meet the needs of the vast majority of gas extraction
The flow calibration of sample instruments is widely applicable to metrological verification, environmental monitoring, labor protection and health, scientific research institutes, and other areas that require gas flow calibration
occasion
2、 Execution standards
JJG 586-2006 "Verification Regulations for Soap Film Flowmeters"
HJ/T 368-2007 "Orifice flow meters for calibrating total suspended particulate matter samplers"
3、 Product Features
◆ Specially equipped with national metrology department calibration certificates to ensure measurement accuracy;
◆ Can manually input and measure temperature and atmospheric pressure;
Direct reading of traffic, automatic conversion of standard flow rate;
◆ AC/DC dual-use, built-in high-energy lithium battery;
Large capacity data storage, querying, and printing;
Chinese dot matrix LCD display screen with rich interface display;
◆ Software parameter calibration;
◆ User password protection;
◆ Automatic fault detection and protection.
Technical Indicators:
1. Measurement and detection range:
Soap film flowmeter: (100-5000) mL/min, resolution of 0.1ml, accuracy better than ± 1%
Membrane flowmeter: (5-80) L/min, resolution of 0.1L, accuracy better than ± 1%
Mid orifice flowmeter section: 80-150L/min, resolution 0.1L, accuracy better than ± 1%
Large orifice flowmeter section: 8001200L/min, resolution 1L, accuracy better than ± 1%
2. Flow detection repeatability error: ± 0.5%
3. Environmental temperature: -40-90 ℃, resolution of 1 ℃, accuracy better than ± 1 ℃
4. Micro pressure measurement range: 0-2500Pa, resolution of 1 Pa, accuracy better than ± 1%
5. Pre gauge pressure measurement range: -30~30kPa, resolution of 0.01KPa, accuracy better than ± 2.0%
6. Environmental atmospheric pressure: 80-106kPa, resolution of 0.01KPa, accuracy better than ± 0.5KPa
7. Built in battery working time:>6 hours
8. Working current: DC12V, 2A
9. Power consumption:<10W
Instrument configuration: device host, power cord, hose, instruction manual, etc
2.Model of small diamond wire cutting machine;H09279
Product Model:
H09279Small diamond wire cutting machine
Product Introduction:
H09279The small diamond wire cutting machine is designed specifically for material researchers for precision cutting of brittle material analysis samples, such as crystals, ceramics, glass, refractory materials, rock samples, mineral samples, building materials, metals, plastics, PCBs, etc. It is particularly suitable for precision cutting of ultra-thin samples, with the thinnest sample thickness reaching 0.1 millimeters. The product has passed CE certification and is exported to research institutes, universities, research departments of large enterprises, as well as small and medium-sized enterprises related to material analysis around the world.
Product Usage
Suitable for precision cutting of material analysis samples, such as crystals, ceramics, glass, refractory materials, rock samples, mineral samples, building materials, metals, plastics, PCB boards, etc.
Key Features:
1. It can be used for cutting various hardness crystals, ceramics, glass, refractory materials, lithological samples, especially suitable for processing brittle and easily cleavable crystals.
2. Using diamond wire for cutting is easy to operate and has good processing quality.
3. Adopting aluminum profile structure, it is beautiful, lightweight and stable.
Technical parameters:
1. The cutting wire transport speed can be adjusted within the range of 0-1.5m/s
2. The total length of the cutting line is ≤ 15m
3. Cutting wire diameter ≤ 0.42mm
4. The maximum stroke of worktable Z is 50mm, and the maximum stroke of worktable Y is 50mm
5. The indication accuracy of Y and Z axis feed is 0.01mm
6. Two dimensional adjustment workbench rotates 360 ° horizontally and 10 ° vertically, with a positioning accuracy of 5 '
7. Cutting maximum workpiece diameter and length Ø 50mm × 50mm
Product Specifications
1. Dimensions: 450mm in length, 370mm in width, and 750mm in height
2. Net weight: 30kgs
3.Current and voltage calibrator/Handheld signal generation verification device Model:H09278
H09278The current and voltage calibrator is a device that combines output and measurementVThemVThemATheHzA handheld calibration instrument that integrates signals with high precision, high resolution, and high reliability. The instrument adopts a large LCD display with clear readings, and also has adjustable backlight and automatic shutdown functions. The instrument can be powered by DC or AC power, making it more convenient to use.
★Protection function: Waterproof ratingIP67Wrong connection at any signal end220VAutomatic protection;
★measurement/Output: voltage, current, frequency, millivolts, with current output supporting active and passive;
★Can simulate two-wire transmitters;
★The accuracy is0.05%;
★Can provide manual stepping, automatic stepping0~100%Step and slope output functions;
★With white colorLEDBacklight, with manual backlight adjustment and automatic power off function, suitable for on-site use;
★provideDC24VCircuit power supply for on-site debugging purposes;
★Battery box cover, easy to replace;
List of Output and Measurement Functions
technical indicators
Unless otherwise specified, all indicators are based on a one-year calibration cycle and applicable to+18℃to+28℃The temperature range. All indicators are assumed to have10Minute startup preheating time.
DC voltage measurement
DC voltage output
DC current measurement
DC current output
frequency measurement
frequency output
Other parameters
Operating temperature:-10℃~55℃
Storage temperature:-20℃~60℃
Weight: 350 grams
Overall dimensions:185mm*93mm*47mm
Power supply method:6-section 7 # nickel hydrogen battery or AC adapter
4.Capacitive remote transmission differential pressure/Pressure transmitter model;H09272
CECC/CECYCapacitive differential pressure/pressure transmitter with capillary remote transmission flangeRTWThePFWTheEFWTheRFW)Later becameCECC/CECYType capacitive remote differential pressure/pressure transmitter. thereforeCECC/CECYThe capacitive remote differential pressure/pressure transmitter still hasCECC/CECYVarious characteristics of differential pressure/pressure transmitters.
Applicable scenarios
CECC/CECYRemote differential pressure/pressure transmitters can avoid direct contact between the measured medium and the isolation diaphragm of the transmitter. They are suitable for the following situations:
(1)When the tested medium has a corrosive effect on the transmitter connector and sensitive components;
(2)When it is necessary to isolate the high-temperature measured medium from the transmitter;
(3)When there are solid suspended solids or high viscosity fluids in the measured medium that can easily block the transmitter connector and pressure chamber;
(4)When the tested medium is easily solidified or crystallized when led out with a pressure tube;
(5)When replacing the tested medium and flushing is required to prevent mixing;
(6)Hygiene conditions must be maintained to prevent contamination.
Product Features
High precision and good stability
Two wire system (special four wire system)
Solid components, plug-in printed circuit boards
Small, lightweight, sturdy and vibration resistant
Range and zero point are continuously adjustable externally
adjustable damping
Good one-way overload protection characteristics
No mechanical movable parts, low maintenance workload
Unified structure across the entire series, with strong interchangeability of components
The membrane material in contact with the medium can be selected(316LTheTANHa Shi JinC-276TheMONELWaiting for corrosion-resistant materials)
Explosion proof structure, all-weather use
· Parameters and specifications:
· working principle
The process pressure is transmitted through the isolation membrane on both sides or one side, and the filling liquidδThe central measuring diaphragm of the chamber is a tensioned elastic element that produces corresponding deformation displacement for the pressure difference acting on it on both sides. Its displacement is proportional to the differential pressure, and the maximum displacement is about0.1mmThis displacement is transformed into a differential capacitor formed on the capacitor plate, which is converted into a two-wire system by electronic circuits4~20mA DCOutput signal.
Functional Parameters
Target audience: liquids, gases, and vapors
Measurement range:0-0.16kpato0-40Mpa
Output signal:4~20mA DC(Special can be four wire system)220V ACPower supply,0~10mA DCOutput)
Power supply:12~45V DC,generally24V DC
Load characteristics: related to the power supply,load impedanceRLCompared to the power supply voltageVSThe relationship isRL≤50(VS-12)
Indicator: pointer type linear indication0~100%Linear scale and square root indication0~100%Flow scale, and31/2bitLCDLCD display(0~100%Linear)
Explosion proof:a.Explosion proof typeEX d II BT5Explosion proof certificate numberGYB 02532
b.Intrinsic safety typeEX ia CT6Explosion proof certificate numberGYB 02533
Range and zero point: externally continuously adjustable
Positive and negative transfer: After the zero point undergoes positive and negative transfer, the absolute values of the upper and lower limits of the measuring range and measurement range cannot exceed the upper limit of the measurement range100%The maximum positive migration is the minimum calibration range500%The maximum negative transfer is the minimum calibration range600%.
The maximum positive and negative transfer of the flow transmitter is the calibrated flow range10%.
Temperature range: Amplifier operating temperature range:-29~+93℃CECLType:-25~70℃ Explosion proof type:-20+60℃
Equipped with LCD display:+20~+70℃
Measuring element filled with silicone oil:+40~!+104℃
When filling high-temperature silicone oil into a flange transmitter:+15~+315℃, ordinary silicon reservoir:-40~+150℃
Static pressure and overload pressure:4、10、25The32Mpa
Humidity: The relative humidity is0~100%
Volume suction capacity: <0.16cm3
When filling silicone oil with damping (step response), it is generally0.2sto1.67sContinuously adjustable between
Start time:2sNo preheating required
Technical data
(Without migration, under standard working conditions, filled with silicone oil,316LStainless steel isolation membrane
Accuracy level:±0.2%,±0.25%,±0.5%
Dead zone: None(≤0.1%)
Stability: Within twelve months, the accuracy of the transmitter shall not exceed
5.Dew point meter/temperature and humidity meter model:H09271
Measurement range: Humidity: 10-95% RH
Dew point: -60~60 ℃
Temperature: -10~65 ℃
Resolution: 0.1
Accuracy: Dew point temperature: ± 0.1 ℃
Humidity: 2.5% ± 1% RH
Temperature: ± 0.5 ℃
Power supply: 4 No. 5 batteries
Dimensions: 220X72X37
The above parameter information corresponds to the image