Detection of dissolved gas component content in transformer oilastroubleshootRunningA type of transformer faulteffectivemeans,averageConducted in three scenarios: offline/Laboratory, on-site, and online. Under existing technology, the data provided by offline detectionmoreAccurate, butThe detection in this scenario relies on manual sampling,detectionandLow timeliness; on-site testingmoreFor flexibility, but with the obtained dataComparability between themPoor, and between different detection instrumentsProne to deviationData availabilitycompareLow; Online detectionandTimelinesstallBut the dataPoor stabilityThe above issues result in the same measurement being taken in different scenariosTaiwanThe content data of dissolved gas components in transformer oil cannot be compared between transformers,Unable to fully utilize the ability of detecting the content of dissolved gas components in transformer oil to determine potential faults in transformers.
@DGA-2020The portable transformer oil spectrophotometer isDeveloped by Aite Zhilian Technology (Shanghai) Co., LtdofChromatograph for detecting the content of dissolved gas components in transformer oil under multiple scenarios.This device integratesHydrogen air integrated module, automatic degassing and sampling module, chromatographic detection module, and computer centralized control workstation moduleFour major modules. itsAdopting the classic three detector process, onceinjectionjustautomaticcompletetransformerDissolve in oilDegassing of gases, andH2TheCOTheCO2TheCH4TheC2H4TheC2H6TheC2H2wait7Full analysis of gas component content.
In addition,@DGA-2020Portable Transformer Oil SpectrometerCan freely switch usage scenarios according to actual needsJust needa@DGA-2020It can meet the offline requirement of dissolved gases in transformer oil/Testing in three scenarios: laboratory, on-site, and online. And the data measured in different scenarios have good repeatability and continuity, which can provide reliable basis for transformer fault diagnosis.
nApplicable standard


| 1. GB/T 17623-2017 | Determination of dissolved gas components in insulating oil by gas chromatography |
| 2. DL/T 722-2014 | Guidelines for Analysis and Determination of Dissolved Gases in Transformer Oil |
| 3. DL/T 1432.2-2016 | Inspection Specification for Online Monitoring Devices of Substation Equipment Part 2: Online Monitoring of Dissolved Gases in Transformer Oil |
| 4. DL/T 1498.2-2016 | Technical specification for online monitoring device of substation equipment Part 2: Online monitoring device for dissolved gases in transformer oil |
| 5. DL/T 2145.1-2020 | Guidelines for on-site testing of online monitoring devices for substation equipment - Part 1: Online monitoring devices for dissolved gases in transformer oil |
| 6. QGDW 10536-2021 | Technical specification for online monitoring device for dissolved gases in transformer oil |
| 7. IEC60567-2012 | Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance |