Welcome Customer !

Membership

Help

Taiwan, China Ultramicro Optics Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Portable Raman spectroscopy analyzer

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The portable Raman spectrometer has a streamlined architecture and optimized spectral analysis core. In spectral measurement, its optical architecture can provide very robust and stable measurement performance, especially with excellent temperature, humidity, vibration, and impact stability in resolution and wavelength drift.

Product Details

Sidewinder - TE cooled seriesPortable Raman spectroscopy analyzerIt is composed of InGaAs line sensors and 32bits RISC microcontrollers, specifically designed for detecting near-infrared spectra. Having a streamlined architecture and optimized spectral analysis core. In spectral measurement, its optical architecture can provide very robust and stable measurement performance, especially with excellent temperature, humidity, vibration, and impact stability in resolution and wavelength drift.

The rattlesnake cooling SW 8 series (SW2830) has TECooling first-order cooling function.

The rattlesnake cooling SW 9 series has a frequency range of 900~2500nm (SW2960) and features TECooling second-order cooling function.

Having good performance and agile system designPortable Raman spectroscopy analyzerNear infrared spectrometer:

1. Minimum cooled near-infrared spectrometer with a volume of only 130 x 96 x 55 mm3

2. SW2960 is a high-order near-infrared spectroscopy model with a maximum spectral range of 900~2500nm

3. High sensitivity, high signal-to-noise ratio, high resolution

4. TEC first-order refrigeration (SW2860), second-order refrigeration (SW2960)

5. Competitive prices in the high specification application market

6. High gain or low gain modes can be selected, with high gain having an average sensitivity about 18 times lower than low gain

7. Selection of 1064nm Raman, Film Thickness, Food, Pharmaceutical, Environmental, and Biochemical Detection Applications

8. SMA905, FC/PC connector optional

SW-TEC sensor selection:

Model number SW2860 SW2960
sensor 256 pixels 256 pixels
TE-Cooled First-order refrigeration
(Environmental temperature 25 ℃)
Can be lowered to 0 ℃)
Second stage refrigeration
(Environmental temperature 25 ℃)
Can be lowered to -15 ℃)
Wavelength Range 900 - 1700 nm 900 - 2500 nm
optical resolution slit
50um
~7nm, Avg.:4.5 ~15nm, Avg.:10
Slit 100um ~10nm Avg.: 8.5 ~21nm, Avg.:18
integration time high gain
pattern
100 μs ~ 24s 100us-20ms
Low gain
pattern
100 μs ~ 24s 100us-200ms
Signal-to-noise ratio high gain
pattern
na.(>2500) 1000
Low gain
Mode (default)
na.(>5000) 2000
Dark noise high gain
pattern
na.(<18) 30
Low gain
Mode (default)
na.(<18) na. (<30)
dynamic range high gain
pattern
na.(~5000) na.(~3640)
Low gain
Mode (default)
na.(>5000) na. (>3640)
Wavelength accuracy <1nm <1nm
Optical information parameters V
Timely calculation V
Continuous high-speed exposure V

The SW series offers two different sensitivity mode options: High Gain and Low Gain

SW 8 series, the difference between enabling cooling and non cooling functions: