- Phone
-
Address
No.5, Floor 9, No. 27, Guanxin Road, Hsinchu, Taiwan, China, China
Taiwan, China Ultramicro Optics Co., Ltd
No.5, Floor 9, No. 27, Guanxin Road, Hsinchu, Taiwan, China, China
Sidewinder - TE cooled seriesPortable Raman spectroscopy analyzerIt is composed of InGaAs line sensors and 32bits RISC microcontrollers, specifically designed for detecting near-infrared spectra. Having a streamlined architecture and optimized spectral analysis core. In spectral measurement, its optical architecture can provide very robust and stable measurement performance, especially with excellent temperature, humidity, vibration, and impact stability in resolution and wavelength drift.
The rattlesnake cooling SW 8 series (SW2830) has TECooling first-order cooling function.
The rattlesnake cooling SW 9 series has a frequency range of 900~2500nm (SW2960) and features TECooling second-order cooling function.
Having good performance and agile system designPortable Raman spectroscopy analyzerNear infrared spectrometer:
1. Minimum cooled near-infrared spectrometer with a volume of only 130 x 96 x 55 mm3
2. SW2960 is a high-order near-infrared spectroscopy model with a maximum spectral range of 900~2500nm
3. High sensitivity, high signal-to-noise ratio, high resolution
4. TEC first-order refrigeration (SW2860), second-order refrigeration (SW2960)
5. Competitive prices in the high specification application market
6. High gain or low gain modes can be selected, with high gain having an average sensitivity about 18 times lower than low gain
7. Selection of 1064nm Raman, Film Thickness, Food, Pharmaceutical, Environmental, and Biochemical Detection Applications
8. SMA905, FC/PC connector optional
SW-TEC sensor selection:
| Model number | SW2860 | SW2960 | |
| sensor | 256 pixels | 256 pixels | |
| TE-Cooled | First-order refrigeration (Environmental temperature 25 ℃) Can be lowered to 0 ℃) | Second stage refrigeration (Environmental temperature 25 ℃) Can be lowered to -15 ℃) | |
| Wavelength Range | 900 - 1700 nm | 900 - 2500 nm | |
| optical resolution | slit 50um | ~7nm, Avg.:4.5 | ~15nm, Avg.:10 |
| Slit 100um | ~10nm Avg.: 8.5 | ~21nm, Avg.:18 | |
| integration time | high gain pattern | 100 μs ~ 24s | 100us-20ms |
| Low gain pattern | 100 μs ~ 24s | 100us-200ms | |
| Signal-to-noise ratio | high gain pattern | na.(>2500) | 1000 |
| Low gain Mode (default) | na.(>5000) | 2000 | |
| Dark noise | high gain pattern | na.(<18) | 30 |
| Low gain Mode (default) | na.(<18) | na. (<30) | |
| dynamic range | high gain pattern | na.(~5000) | na.(~3640) |
| Low gain Mode (default) | na.(>5000) | na. (>3640) | |
| Wavelength accuracy | <1nm | <1nm | |
| Optical information parameters | V | ||
| Timely calculation | V | ||
| Continuous high-speed exposure | V | ||
The SW series offers two different sensitivity mode options: High Gain and Low Gain

SW 8 series, the difference between enabling cooling and non cooling functions: