- Phone
-
Address
Building 6, Optics Valley Electromechanical Industrial Park, No. 84 Gaoxin 5th Road, Donghu New Technology Development Zone, Wuhan City, Hubei Province
Wuhan Ultra High Voltage Power Technology Co., Ltd
Building 6, Optics Valley Electromechanical Industrial Park, No. 84 Gaoxin 5th Road, Donghu New Technology Development Zone, Wuhan City, Hubei Province
Portable DC High Voltage GeneratorAdopting high-frequency voltage doubling circuit, applying PWM high-frequency pulse width modulation technology, closed-loop adjustment, and adopting voltage feedback, the voltage stability is greatly improved. Use high-performance high-power IGBT devices and driving technology, and adopt special shielding, isolation, and grounding measures based on electromagnetic compatibility theory. The DC high-voltage generator achieves high quality, portability, and can withstand rated voltage discharge without damage. It has the characteristics of high output power and small size, reliable overvoltage, overcurrent, and zero position closing protection functions, and has a 0.75 times voltage switching function. It is mainly suitable for power departments, industrial and mining, metallurgy, steel and other enterprises to conduct DC withstand voltage tests or DC leakage current tests on high-voltage electrical equipment such as zinc oxide lightning arresters, power cables, transformers, circuit breakers, generators, etc.
Product Name: DC High Voltage Generator, DC High Voltage Generator, High Voltage Generator, Medium Frequency DC High Voltage Generator, ZGF DC High Voltage Generator, Power Frequency High Voltage Generator, High Voltage Generator DC High Voltage Generator
Portable DC High Voltage GeneratorScope of application
1. Conductivity current test of valve type lightning arrester.
2. DC withstand voltage test and leakage current measurement of power transformers.
3. DC withstand voltage test and leakage current measurement of high-voltage cables (35-500kV and below).
4. U1mA DC reference voltage test and 0.75U1mA leakage current test for zinc oxide lightning arrester.
Product parameters
Technical specifications
Specifications |
200/2 |
200/3 |
200/5 |
300/2 |
300/3 |
300/5 |
Rated voltage (kV) |
200 |
200 |
200 |
300 |
300 |
300 |
Rated current (mA) |
2 |
3 |
5 |
2 |
3 |
5 |
Rated power (W) |
400 |
600 |
1000 |
600 |
900 |
1500 |
Control box mass (kg) |
5.5 |
6.0 |
6.5 |
6.5 |
6.5 |
7.5 |
Mass of pressure doubling cylinder (kg) |
10.3 |
10.3 |
10.3 |
11.5 |
11.5 |
11.5 |
Height of pressure doubling cylinder (mm) |
970 |
970 |
970 |
1250 |
1250 |
1250 |
voltage accuracy |
± (1.0% reading+2 words) |
|||||
Current accuracy |
± (1.0% reading+2 words) |
|||||
Ripple coefficient |
≤0.5% |
|||||
Voltage stability |
≤ 1% when the power supply voltage changes by ± 10% |
|||||
overload capacity |
The no-load voltage can exceed the rated voltage by 10% and be used for 10 minutes |
|||||
The charging current is 1.25 times the rated current | ||||||
power supply |
Single phase AC 50Hz 220V ± 10% |
|||||
working method |
Intermittent use: rated load for 30 minutes |
|||||
1.1 times rated voltage usage: 10 minutes | ||||||
working environment |
Temperature: -10 ℃ to+40 ℃ |
|||||
Relative humidity: not exceeding 85% at room temperature of 25 ℃ (no condensation) | ||||||
Altitude: below 1500 meters | ||||||
Capacity with capacitive load |
The capacitance of the test sample is unlimited |
|||||
Can be charged with 1.5 times the rated current | ||||||
structural characteristics |
Electrical insulation voltage doubling cylinder |
|||||
Air insulation, no leakage concerns | ||||||
Characteristics of the operation box |
High precision 0.75UDC1mA single touch button (accuracy ≤ 1.0%), suitable for testing zinc oxide lightning arresters |
|||||
Overvoltage protection adopts digital dip switch, which is clear at a glance | ||||||
Portable chassis, more convenient on-site | ||||||
Note:
1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued.
2. For more information on ultra-high voltage products, please enter the product center.
Selection Reference
Selection Reference - Zinc Oxide Surge Arrester DC Reference Voltage and Leakage Current Test
Rated voltage of lightning arrester (kV) |
10 |
35 |
66 |
110 |
220 |
DC reference voltage kV |
28 |
90 |
135 |
168 |
314 |
Equipment selection kV/mA |
ZGF - 60 / 2 |
ZGF - 120 / 2 |
ZGF - 200 / 2 |
ZGF - 200 / 2 |
ZGF - 400 / 3 |
Selection reference - choose according to the voltage level of the substation
Substation voltage level kV |
10 |
35 |
66 |
110 |
220 |
330 |
Test voltage kV |
47 |
105 |
135 |
192 |
305 |
Greater than 400 |
Equipment selection kV/mA |
ZGF - 60 / 2 |
ZGF - 120 / 2 |
ZGF - 200 / 2 |
ZGF - 200 / 2 |
ZGF - 400 / 3 |
ZGF - 800 / 10 |
Selection reference - choose based on the qualification level of repair and testing
Maintenance and testing level |
Level 5 |
Level 4 |
Level 3 |
Level 2 |
Level 1 |
Test voltage kV |
28 |
90 |
168 |
305 |
Greater than 400 |
Equipment selection kV/mA |
ZGF - 60 / 2 |
ZGF - 120 / 2 |
ZGF - 200 / 2 |
ZGF - 400 / 3 |
ZGF - 800 / 10 |
Selection reference - DC withstand voltage and leakage current test of paper insulated cable
Rated voltage of cable Uo/U kV |
3.6 / 6 |
6 / 6 |
6 / 10 |
8.7 / 10 |
21 / 35 |
26 / 35 |
DC test voltage kV |
17 |
30 |
40 |
47 |
105 |
130 |
Equipment selection kV/mA |
ZGF - 60 / 2 |
ZGF - 60 / 2 |
ZGF - 60 / 2 |
ZGF - 60 / 2 |
ZGF - 120 / 3 |
ZGF - 200 / 5 |
Selection reference - Rubber insulated cable DC withstand voltage and leakage current test
Rated voltage of cable Uo/U kV |
6 / 10 |
8.7 / 10 |
21 / 35 |
26 / 35 |
48 / 66 |
64 / 110 |
127 / 220 |
DC test voltage kV |
26 |
37 |
63 |
78 |
144 |
192 |
305 |
Equipment selection kV/mA |
ZGF - 60 / 2 |
ZGF - 60 / 2 |
ZGF - 120 / 5 |
ZGF - 120 / 5 |
ZGF - 200 / 5 |
ZGF - 200 / 10 |
ZGF - 400 / 5 |
Selection reference - DC withstand voltage and leakage current test for main insulation of self accommodating oil filled cable
Rated voltage of cable Uo/U kV |
48 / 66 |
64 / 110 |
127 / 220 |
190 / 330 |
290 / 500 |
DC test voltage kV |
175 |
275 |
475 |
585 |
775 |
Equipment selection kV/mA |
ZGF - 200 / 3 |
ZGF - 300 / 3 |
ZGF - 500 / 5 |
ZGF - 600 / 5 |
ZGF - 800 / 10 |
Product features
1. DC high voltage generator has low ripple coefficient, stable and reliable voltage output, no noise, and good reliability
2. Equipped with overvoltage, overcurrent, zero voltage starting and fault protection functions, the voltage protection value can be set and displayed intuitively
3. Voltage and current are displayed digitally, and there are readings when the power is turned on, making it easy to monitor the output status
4. Equipped with 0.75 times voltage conversion, convenient for testing zinc oxide lightning arresters
5. The product has a compact structure, small size, and is easy to carry







Product Video Product Atlas
Product Attachment Diagram

DC high voltage generator

control box

Double pressure cylinder

Double pressure cylinder

current-limiting resistor

discharge rod

Microampere meter

connecting cable

High voltage line (with shielding)

Special grounding wire

power cord

fuse
Product detail images

the whole set

control box

Front of control box

Control box panel

Voltage display screen

Current display screen

High voltage on/off

Voltage adjustment knob

grounding post

Overvoltage setting DIP

Cable interface

Control box power supply

Voltage doubling cylinder wiring aviation plug

Voltage doubling cylinder ground wire terminal post

Double pressure cylinder rotatable base

High voltage double pressure cylinder box

Corona ring