Welcome Customer !

Membership

Help

Gengong Valve (Zhejiang) Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Gengong Valve (Zhejiang) Co., Ltd

  • E-mail

  • Phone

  • Address

    Dongou Industrial Zone, Oubei Street, Yongjia County, Wenzhou City, Zhejiang Province

Contact Now

Pneumatic piston type cut-off valve 2

NegotiableUpdate on 05/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product model: ZSPC nominal diameter: DN20-200mm nominal pressure: PN1.6~6.4MPa medium temperature: soft seal: -40~150 ℃ (normal temperature type); Hard seal: -40~200 ℃ (normal temperature type), -40~450 ℃ (medium temperature type) Main material: ZG230-450; ZG1Cr18NI9 Ti; ZG0Gr18N12Mo2Ti drive mode: Pneumatic design standard: GB/T17213 Flange standard: GB/T9113, JB/T79, HG20594 and other standards Inspection standard: GB/T4213 Connection form: flange (FF RF RTJ), welding (SW BW), thread (applicable to 1 inch or less)

Product Details

Overview of ZSPC Pneumatic Piston Cut off Valve:

ZSPC type pneumatic piston normal temperature and medium temperature cut-off valve consists of a pneumatic piston actuator and a cut-off mechanism. According to the sealing surface material of the valve core, it can be divided into hard seal and soft seal; according to the structure of the valve core, it can be divided into single guide flat plate type and single guide balanced type. It has the characteristics of simple structure, reliable action, tight cutting, and fast closing and opening. Suitable for gas and liquid media without particles or impurities, requiring fast and tight closure and rapid venting in automatic control systems.


1、 Model and specifications

model
room temperature type
hard seal
room temperature type
soft seal
Medium temperature type
hard seal
Room temperature type hard seal
Sealing handwheel
Room temperature soft seal with handwheel
Medium temperature hard seal with handwheel
model
ZSP NC1-
(16/64)B K
ZSP NC2-
(16/64)B K
ZSP NC1-
(40/64)B KG
ZSPC1-
(16/64)B K
ZSPC2-
(16/64)B K
ZSPC1-
(40/64)B K
specification
DN20-200


2、 Main technical parameters and performance indicators

1. Main technical parameters of the cutting mechanism

Nominal pressure mm
20
25
40
50
65
80
100
150
200
Valve seat diameter mm
20
25
32
40
50
65
80
100
125
150
200
Rated flow coefficient Kv
6.5
10
15
25
40
65
100
125
260
350
540
Nominal pressure MPa
1.6; 4.0; six point four
Travel distance mm
10
16
25
30
40
60
flow characteristics
Quick open
Medium temperature ℃
Soft seal: -40~150 (normal temperature type); Hard seal: -40~200 (normal temperature type), -40~450 (medium temperature type)
Flange size and type
PN16 according to JB78-59 smooth type; PN40、 64 according to JB/T79.2-94 concave
Valve body material
ZG230-450; ZG1Cr18NI9 Ti; ZG0Gr18N12Mo2Ti
Valve seat and valve core material
1 CR 18 by 9 ; 0 CR 18 of 12 mo 2 Ti
Upper valve cover type
Ordinary type (constant temperature type); Hot plate (medium temperature type)

Note: GB, ANSI, JP, JIS, DIN and other flange structure types can be provided, and the flange distance can be determined according to user needs.

2. Matching relationship between the main technical parameters of the executing mechanism and the cutting mechanism

Nominal diameter mm
Model of actuator
Cylinder diameter mm
Travel distance mm
inlet hole thread
remark
room temperature type
Medium temperature type
room temperature type
Medium temperature type
room temperature type
Medium temperature type
ZSP: Single acting
ZSP: Double acting
20
ZSPA B - 1
ZSPA B - 1
Zsn -1
150
150
10
M16×1.5
M16×1.5
25
40
ZSPA B - 2
Zsn -1
200
16
50
65
ZSPA B - 2
ZSPA B - 3
Zsn -2
200
300
25
M20×1.5
80
100
30
150
ZSPA B - 3
ZSPA B - 4
Zsn -3
300
400
40
M20×1.5
M24×2
200
60


3. Performance indicators

Nominal pressure mm
20
25
40
50
65
80
100
150
200
Valve seat diameter mm
20
25
32
40
50
65
80
100
125
150
200
Leakage rate of soft seal
Water test
△P=△ Pmax mlmin
0
Gas test
△ P=0.35MPa Bubble count/min
1
1
2
3
4
6
11
18
27
45
Leakage rate of hard seal
Water test MPa
4.0
3.0
ml/min
0.24
0.30
0.38
0.48
0.60
0.78
0.96
1.2
1.125
1.35
1.8
Gas test
△ P=0.35MPa ml/min
23.3
29.2
37.3
46.7
58
75.8
93.3
116.7
145.8
175
233.3
Cut off time S
0.5
1
1.5
2
3
4
Rated travel deviation%
±6


4. Allowable pressure difference:

Nominal diameter mm
20
25
40
50
65
80
100
150
200
Cylinder diameter mm
150
200
300
400
Gas source pressure KPa
500
Allow pressure difference
Whole machine air closed type
Flow open
4.0
4.0
2.6
2.2
3.8
2.6
2.0
1.95
1.59
Flow off
4.0
4.0
4.0
3.1
3.1
3.2
1.6
2.0
1.63
Whole machine pneumatic open type
Flow open
4.0
3.0
2.1
1.7
1.7
1.1
0.9
0.52
0.43
Flow off
4.0
4.0
4.0
4.0
4.0
3.6
2.7
3.4
2.2


3、 External dimensions:

Nominal diameter DN
20
25
40
50
65
80
100
150
200
L
PN
MPa
1.6
194
197
235
267
292
317
368
500
635
4.0
650
6.4
206
210
251
286
311
337
394
520
650
H
65
70
85
90
100
105
125
170
205
without handwheel
H1
room temperature type
445
455
485
485
605
605
620
962
988
Medium temperature type
596
606
636
636
770
770
785
1178
1226
With handwheel
H1
room temperature type
630
640
670
670
790
790
805
1087
1113
Medium temperature type
781
791
821
821
955
955
970
1303
1351
H2
160
160
160
160
160
160
270
270
270
H3
220
220
220
220
220
220
390
390
390