- Phone
-
Address
Dongou Industrial Zone, Oubei Street, Yongjia County, Wenzhou City, Zhejiang Province
Gengong Valve (Zhejiang) Co., Ltd
Dongou Industrial Zone, Oubei Street, Yongjia County, Wenzhou City, Zhejiang Province
Overview of ZSPC Pneumatic Piston Cut off Valve:
ZSPC type pneumatic piston normal temperature and medium temperature cut-off valve consists of a pneumatic piston actuator and a cut-off mechanism. According to the sealing surface material of the valve core, it can be divided into hard seal and soft seal; according to the structure of the valve core, it can be divided into single guide flat plate type and single guide balanced type. It has the characteristics of simple structure, reliable action, tight cutting, and fast closing and opening. Suitable for gas and liquid media without particles or impurities, requiring fast and tight closure and rapid venting in automatic control systems.
1、 Model and specifications
| model |
room temperature type hard seal |
room temperature type soft seal |
Medium temperature type hard seal |
Room temperature type hard seal Sealing handwheel |
Room temperature soft seal with handwheel |
Medium temperature hard seal with handwheel |
| model |
ZSP NC1- (16/64)B K |
ZSP NC2- (16/64)B K |
ZSP NC1- (40/64)B KG |
ZSPC1- (16/64)B K |
ZSPC2- (16/64)B K |
ZSPC1- (40/64)B K |
| specification |
DN20-200 |
|||||
2、 Main technical parameters and performance indicators
1. Main technical parameters of the cutting mechanism
| Nominal pressure mm |
20 |
25 |
40 |
50 |
65 |
80 |
100 |
150 |
200 |
||
| Valve seat diameter mm |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
| Rated flow coefficient Kv |
6.5 |
10 |
15 |
25 |
40 |
65 |
100 |
125 |
260 |
350 |
540 |
| Nominal pressure MPa |
1.6; 4.0; six point four |
||||||||||
| Travel distance mm |
10 |
16 |
25 |
30 |
40 |
60 |
|||||
| flow characteristics |
Quick open |
||||||||||
| Medium temperature ℃ |
Soft seal: -40~150 (normal temperature type); Hard seal: -40~200 (normal temperature type), -40~450 (medium temperature type) |
||||||||||
| Flange size and type |
PN16 according to JB78-59 smooth type; PN40、 64 according to JB/T79.2-94 concave |
||||||||||
| Valve body material |
ZG230-450; ZG1Cr18NI9 Ti; ZG0Gr18N12Mo2Ti |
||||||||||
| Valve seat and valve core material |
1 CR 18 by 9 ; 0 CR 18 of 12 mo 2 Ti |
||||||||||
| Upper valve cover type |
Ordinary type (constant temperature type); Hot plate (medium temperature type) |
||||||||||
Note: GB, ANSI, JP, JIS, DIN and other flange structure types can be provided, and the flange distance can be determined according to user needs.
2. Matching relationship between the main technical parameters of the executing mechanism and the cutting mechanism
| Nominal diameter mm |
Model of actuator |
Cylinder diameter mm |
Travel distance mm |
inlet hole thread |
remark |
|||
| room temperature type |
Medium temperature type |
room temperature type |
Medium temperature type |
room temperature type |
Medium temperature type |
ZSP: Single acting ZSP: Double acting |
||
| 20 |
ZSPA B - 1 |
ZSPA B - 1 Zsn -1 |
150 |
150 |
10 |
M16×1.5 |
M16×1.5 |
|
| 25 | ||||||||
| 40 |
ZSPA B - 2 Zsn -1 |
200 |
16 |
|||||
| 50 | ||||||||
| 65 |
ZSPA B - 2 |
ZSPA B - 3 Zsn -2 |
200 |
300 |
25 |
M20×1.5 |
||
| 80 | ||||||||
| 100 |
30 |
|||||||
| 150 |
ZSPA B - 3 |
ZSPA B - 4 Zsn -3 |
300 |
400 |
40 |
M20×1.5 |
M24×2 |
|
| 200 |
60 |
|||||||
3. Performance indicators
| Nominal pressure mm |
20 |
25 |
40 |
50 |
65 |
80 |
100 |
150 |
200 |
|||
| Valve seat diameter mm |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
|
| Leakage rate of soft seal |
Water test △P=△ Pmax mlmin |
0 |
||||||||||
| Gas test △ P=0.35MPa Bubble count/min |
1 |
1 |
2 |
3 |
4 |
6 |
11 |
18 |
27 |
45 |
||
| Leakage rate of hard seal |
Water test MPa |
4.0 |
3.0 |
|||||||||
| ml/min |
0.24 |
0.30 |
0.38 |
0.48 |
0.60 |
0.78 |
0.96 |
1.2 |
1.125 |
1.35 |
1.8 |
|
| Gas test △ P=0.35MPa ml/min |
23.3 |
29.2 |
37.3 |
46.7 |
58 |
75.8 |
93.3 |
116.7 |
145.8 |
175 |
233.3 |
|
| Cut off time S |
0.5 |
1 |
1.5 |
2 |
3 |
4 |
||||||
| Rated travel deviation% |
±6 |
|||||||||||
4. Allowable pressure difference:
| Nominal diameter mm |
20 |
25 |
40 |
50 |
65 |
80 |
100 |
150 |
200 |
||||
| Cylinder diameter mm |
150 |
200 |
300 |
400 |
|||||||||
| Gas source pressure KPa |
500 |
Allow pressure difference |
Whole machine air closed type |
Flow open |
4.0 |
4.0 |
2.6 |
2.2 |
3.8 |
2.6 |
2.0 |
1.95 |
1.59 |
| Flow off |
4.0 |
4.0 |
4.0 |
3.1 |
3.1 |
3.2 |
1.6 |
2.0 |
1.63 |
||||
| Whole machine pneumatic open type |
Flow open |
4.0 |
3.0 |
2.1 |
1.7 |
1.7 |
1.1 |
0.9 |
0.52 |
0.43 |
|||
| Flow off |
4.0 |
4.0 |
4.0 |
4.0 |
4.0 |
3.6 |
2.7 |
3.4 |
2.2 |
||||
3、 External dimensions:
| Nominal diameter DN |
20 |
25 |
40 |
50 |
65 |
80 |
100 |
150 |
200 |
||
| L |
PN MPa |
1.6 |
194 |
197 |
235 |
267 |
292 |
317 |
368 |
500 |
635 |
| 4.0 |
650 |
||||||||||
| 6.4 |
206 |
210 |
251 |
286 |
311 |
337 |
394 |
520 |
650 |
||
| H |
65 |
70 |
85 |
90 |
100 |
105 |
125 |
170 |
205 |
||
| without handwheel |
H1 |
room temperature type |
445 |
455 |
485 |
485 |
605 |
605 |
620 |
962 |
988 |
| Medium temperature type |
596 |
606 |
636 |
636 |
770 |
770 |
785 |
1178 |
1226 |
||
| With handwheel |
H1 |
room temperature type |
630 |
640 |
670 |
670 |
790 |
790 |
805 |
1087 |
1113 |
| Medium temperature type |
781 |
791 |
821 |
821 |
955 |
955 |
970 |
1303 |
1351 |
||
| H2 |
160 |
160 |
160 |
160 |
160 |
160 |
270 |
270 |
270 |
||
| H3 |
220 |
220 |
220 |
220 |
220 |
220 |
390 |
390 |
390 | ||