Pitot tube anemometer

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Pitot tube anemometer 1. It adopts a 4.6-inch color touch screen. 2. Pressure, differential pressure, wind speed, air volume, temperature, humidity, dynamic pressure, total pressure, and static pressure. 3. The data statistics function calculates the maximum value, minimum value, average value, data retention lock function, and reset function. Switch between Chinese and English. 4. It can record and store 20000 pieces of data Historical data can be queried, average sampling time can be set, upper and lower limit alarm points can be set, density tables can be queried on the instrument, start recording, stop recording, historical recording, and data with time and date markings can be recorded.

Product Details

YIOU brandDP7000APitot tube anemometer

1、 Overview

YIOU brandDP7000AseriesPitot tube anemometerMake youThe pressure test for HVAC is simple. The instrument can use a pitot tube to measure the wind speed, pressure, and volume inside the ductwind-warm syndromeAnd environmental humidity.DP7000AThe operation is simple and can accurately measure differential pressure and static pressure.DP7000AIt can also calculate air volume and has automatic data recording function.The pressure resolution has reached0.01Pa. The air volume resolution reaches 0.01m3/h. Wind speed resolution: 0.01m/s

2、 Advantages and features

1. Adopting a 4.6-inch color touch screen.

2.Pressure, differential pressure, wind speed, air volume, temperature, humidity,Dynamic pressure,Full pressure and static pressure.

3.Data statistics function calculationMaximum value, minimum value, average value, data retention lock function, reset function. Switch between Chinese and English.

4. Recordable storage 20000 pensdata.Historical data can be queried, average sampling time can be set, upper and lower limit alarm points can be set, density table can be queried on the instrument, start recording, stop recording, and historical recording can be set,Record data with time and date markings.

5.programmablePitot tubeK coefficientMeasurement point cross-sectional area0.00001~1000m2Any settingDensity of the medium.

6.connectableK-type thermocouple (Optional) Probe length can be customized

7.Wind speed probe can withstand temperature for a long time550 degrees, with an interval of 1000 degrees.

threeTechnical parameters:

model

Pressure range

resolution

wind speedrange

DP7000A-1

0~±500.00Pa

0.01Pa

1.00~30.00m/s

DP7000A-2

0~±1000.00Pa

0.01Pa

1.00~40.00m/s

DP7000A-3

0~±2000.00Pa

0.01Pa

1.00~50.00m/s

DP7000A-4

0~±3000.00Pa

0.01Pa

1.00~70.00m/s

DP7000A-5

0~±5000.00Pa

0.01Pa

1.00~90.00m/s

DP7000A-6

0~±6000.00Pa

0.01Pa

1.00~100.00m/s

DP7000A-7

0~±8000.00Pa

0.01Pa

1.00~115.00m/s

DP7000A-8

0~±20.00kPa

0.01Pa

1.00~180.00m/s

DP7000A-9

0~±30.00kPa

0.01Pa

1.00~220.00m/s

DP7000A-10

0~±50.00kPa

0.01Pa

1.00~288.00m/s

DP7000A-11

0~±60.00kPa

0.01kPa

1.00~300.00m/s

DP7000A-12

0~±100.00kPa

0.01Pa

1.00~400.00m/s

DP7000A-13

0~±130.00kPa

0.01Pa

1.00~465.00m/s

DP7000A(Water measurement)

0~±8000.00Pa

0.01Pa

0.00~4.00m/s

DP7000A(Water measurement)

0~±100.00kPa

0.01Pa

0.00~15.00m/s

Wind speed accuracy

±2. 5% reading

Wind speed resolution

0.01m/s

Pressure accuracy level

±0.5%FS can be customized with 0.1% FS

air volume range

0~99999999m3/h

Air volume resolution

0.01m3/h

Built in temperature

-20~60

temperature accuracy

±1Resolution: 0.1

External temperature

-20~600(Optional) Note: Probe length can be customized

Built in humidity

0-100%RH

Humidity accuracy

± 3% resolution 0.1% RH

Duct size

1-700CM

volumetric flow rate

Actual wind speed, pressure, actual duct area, andK-coefficient function

data storage

20000 data sets

sampling interval

1s~1h

battery

Lithium battery220V adaptercontinuous work8 hours

unit

Pa,kPa,Mpa,bar,psi,mmH2O,mmHg,m/s,ft/s,m3/h,m3/s,m3/m, l/h, l/m, l/s,℃,RH%

Instrument appearance dimensions

long190 x width 112 x height 52mm (excluding protruding parts)

weight

Instrument weight: approximately550g, Weight including suitcase and accessories: approximately 1800g

standard configuration

One host,L-shapedOne pitot tube, one instruction manual, combinedgridOne copy of warranty card and hose2 packs (1 meter each), one adapter, external temperature probeIncluding handle310mm, Probe length 180mm,One aluminum alloy box

Optional parts

RS485 communication, RS232 interface