1、 Instrument usage
Pine wood nematode rapid detection instrumentThe main processes include isolation of pine wood nematodes, DNA extraction, and fluorescence quantitative PCR detection. It can quickly complete the detection of pine wood nematodes, automatically display the detection results and print the detection report, without the need for manual interpretation, with an accuracy rate of over 99%, greatly improving the efficiency of pine wood nematode detection work. The field rapid detection system is equipped with a portable and mobile operation, providing convenience for the detection of pine wood nematodes in the field. The automated molecular detection system for pine wood nematodes is widely used in forest defense stations, customs, universities, research institutions, and other units.
2、 Instrument features
1. The system has high detection accuracy.
2. The intelligent pine wood nematode DNA rapid detection system is equipped with an automated detection program for pine wood nematode DNA, which does not require complicated program settings and can run automatically with one click. It can not only detect nematode separation solution, but also directly detect pine wood chips without separating nematodes.
3. The system detection task is easy to operate, time-saving and efficient, and suitable for forestry and forest defense departments at all levels. It only takes 60 minutes to complete the entire process including sample processing, DNA extraction, computer-based testing, and result interpretation.
4. By using amplification fluorescence technology, laboratory testing and identification requirements can be completed through the system host.
5. Small size, light weight, and easy to carry. Easily meet the needs of outdoor experiments.
6. Built in 10 inch high-definition capacitive screen PDA, touch screen operation, simple and fast.
7. Marlow high-quality Peltier refrigeration chips, combined with German PT1000 temperature sensor and temperature control mode with electric resistance heating compensation edge, have a heating rate of 7 ℃ and a cooling rate of 5 ℃, greatly reducing the experimental time.
8. The whole board adopts a 3-second fast lighting mode to ensure the consistency of the hole positions in the experimental results.
9. Simple and intuitive software guidance, making it easy to start detection experiments.
3、 Technical parameters
1. High specification aluminum alloy sample slots are used, with good thermal conductivity, corrosion and oxidation resistance, Peltier heating and temperature control, and comprehensive sealing design. Both the sample solution and condensed water will not leak into the Peltier temperature control element and other electronic components below the sample tank, effectively extending the service life of the instrument.
2. Adopting high-precision PT1000 temperature sensor, the temperature control accuracy reaches 0.01 ℃, fully ensuring the accuracy of temperature control.
3. Sample flux: 0.2ml single tube, 0.2ml eight tube.
4. Open reagent consumables system: Any brand of reagent can be selected, suitable for standard 8-tube or 0.2ml PCR single tube
5. Four high-intensity, wide spectrum, long-life LED solid-state light sources, blue, green, red, and yellow, are used to ensure strong light intensity throughout the entire spectral detection range, improve detection sensitivity, and do not generate heat. They have a long service life and are maintenance free for life.
6. High sensitivity detector: Using a highly sensitive photomultiplier tube imported from Japan, the detection sensitivity is even higher.
7. No need for optical path correction: The scanning system can ensure that the signal excitation and detection optical path of each hole are consistent, without the need for optical path correction, so there is no need to occupy an additional correction channel, and true four channel gene detection can be achieved. ★
8. Number of channels: Configure 4 channels.
9. Channel crosstalk: High precision narrow band filters are used to greatly reduce channel crosstalk, and software can also correct crosstalk parameters.
10. Detection sensitivity: It can detect single copy DNA templates and clearly distinguish between 1000 copy and 2000 copy plasmid DNA
11. Linear detection range: 10 orders of magnitude ★
12. Support commonly used fluorescent dyes and probe detection methods, such as SYBR Green I,Eva Green,Taqman,FRET,Molecular Beacons,Scorpions,Amplifluor Wait
13. Module temperature range: 4-99 ℃
14. Control mode: PCR operating system built-in to the system screen or Windows computer ★
15. Interface: Computer USB connection
16. Working noise: The working noise during operation does not exceed 60 dB
17. Operation analysis software
17.1 It is possible to define sample holes after running the program, saving experimental time
17.2 When running the program, other experimental data results can be opened simultaneously for review and analysis
17.3 The software automatically calculates the baseline range and sets the threshold line, providing users with reliable and accurate data results
17.4 Experimental program setting information and detection results can be directly printed as experimental reports, supporting multiple file formats and data styles such as XLS, CSV, WORD for export ★
17.5 The results of the same batch of experiments can be grouped for independent data analysis, up to a maximum of 6 groups
17.6 Provide software interfaces in both Chinese and English. ★
17.7 software can be installed on multiple computers without any restrictions, without the need to purchase usage rights, and can be upgraded for free for life. ★
Pine wood nematode rapid detection instrumentInstrument technical specifications
| Basic Performance | |
| Overall dimensions | 270*352*195 (mm) |
| weight | 7.5kg |
| power supply | 220V |
| power | Working power 550w |
| operating system | Comes with Android operating system |
| External computer | External Windows computer (Windows 7 or above) |
| system language | Real time switching between Chinese and English |
| communication interface | 方形USB |
| Operating environment parameters | |
| Operating environment temperature | 18~35℃ |
| Relative humidity of operating environment | 0%~85% |
| Transportation and storage temperature | -20~55℃ |
| Relative humidity during transportation and storage | 0%~85% |
| system performance | |
| sample size | 48 holes * 0.2ml |
| Sample volume | 15~100ul |
| Applicable consumables | 0.2ml single tube, 8 × 0.2ml discharge tube |
| Temperature control range | 4~99℃ |
| Hot cover temperature | 30 ℃ -108 ℃ (default 105 ℃, adjustable hot cover temperature) |
| Temperature control method | High performance imported semiconductors |
| Gradient temperature control | 3 modules gradient temperature control, temperature difference support 35 ℃ |
| heating rate | 4.5℃/s(MAX) |
| 降温速率 | 3.4℃/s(MAX) |
| temperature control accuracy | ±0.1℃ |
| Temperature uniformity | ±0.25℃ |
| Temperature accuracy | ±0.1℃ |
| operating function | Preset projects and analysis parameters, easy and convenient to operate |
| report | Support custom report module, 48 hole sub item printing |
| Analysis function | Equipped with multiple qPCR data analysis capabilities, capable of simultaneously detecting 4 detection channels |
| power failure protection | One click restart for interrupted experiments |
| Instrument Information | Having the functions of fault recording, analysis, and prompt, it is more convenient to solve problems remotely |
| analysis algorithm | Amplification curve, standard curve quantification, melting curve, genotyping (SNP), relative quantification |
| Support HRM detection | support |
| Data export | The experimental results can be directly exported in the form of graphics and tables; The detailed data report includes experimental conditions, data coordinates and tables, and data analysis parameters. |
| data format | XLS, CSV, DOCX,PDF |
| TouchDown function | Support time and temperature increasing and decreasing modes |
| Fluorescence detection system performance | |
| Detection sensitivity | Can detect single copy genes |
| dynamic range | 1~10^10 |
| Fluorescence repeatability | CV<1% (Conduct a 48 well homogeneity experiment using a certain brand of reagent, and keep the Ct difference within 0.5 and CV within 1% for the 48 wells.). ) |
| correlation coefficient | 0.99~1 (3 replicates per concentration, correlation coefficient of gradient curve>0.99, amplification efficiency maintained between 99%~101%) |
| Amplification efficiency | 99%~101% |
| 可信度 | Distinguish the concentration difference between 1000 and 2000 copies |
| laser light source | High power LED (maintenance free, long lifespan) |
| detector | High sensitivity photoelectric sensor |
| Stimulate and detect transmission media | High temperature resistant professional optical fiber |
| Excitation light wavelength | 460nm~480nm , 525nm~545nm, 575nm~595nm ,600nm~620nm |
| Detecting light wavelength | 505nm~525nm , 555nm~575nm , 600nm~620nm , 660nm~680nm |