Welcome Customer !

Membership

Help

Changzhou Kemai Experimental Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Changzhou Kemai Experimental Instrument Co., Ltd

  • E-mail

    km@czkemai.net

  • Phone

    18921020220

  • Address

    No. 58 Jinsheng East Road, Jintan District

Contact Now

Photovoltaic module wet leakage current testing system

NegotiableUpdate on 12/28
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Changzhou Kemai Photovoltaic Module Wet Leakage Current Insulation Water Tank is a specially designed wet leakage current testing device for the solar photovoltaic module industry. The experimental purpose is to test the insulation performance of the module under humid working conditions, and to detect whether moisture from rain, fog, dew, or dissolved snow enters the working part of the internal circuit of the module, causing corrosion, leakage, and non safety accidents.
Product Details

1、 Purpose:
Photovoltaic module wet leakage current testing systemTest the insulation performance of the component under humid working conditions, detecting whether moisture from rain, fog, dew, or snow has entered the working part of the internal circuit of the component,Causing corrosion, electrical leakage, and non safety accidents to it. The photovoltaic module wet leakage current testing system is a specially designed wet leakage current testing device for the solar photovoltaic module industry.
2、 Camay Photovoltaic Module Wet Leakage Current Testing SystemKM-PV-WLSystem equipment composition
Experimental sink, sink usage1.5cmThick importsPVCMade of board, with a circulating water tank at the bottom of the sink,PVCPipe, with diameters on both sides of the pipe body5mmSmall hole, stainless steel filter screen installed at the circulating water inlet, one drainage outlet, water switch diameter1″
Temperature controlled sink, temperature controlled22±3℃, using1/4hpPump, outflow flow rate100L/minAt the outlet, a ball valve is used to control the inlet pipe along the edge of the water tank, with multiple holes for diversion, allowing the inlet water to flow evenly.
Heating system, immersion type(SUS304)Stainless steelUType double tube heater, single tube can also be independently adjusted, heating is fast, temperature control is accurate, and the water level in the box is automatically replenished;
Spray device, a spray device containing the same solution. Contains three sprinkler heads, each equipped with a water pressure gauge and a water flow control valve; Control the pressure of each sprinkler head within34.5KpaThe distance from the nozzle to the component is approximately0.9MSpray angle and component composition45 degrees, in accordance withUL1703regulations.
The control cabinet adopts the concept of integrated instrument and equipment control, and the control system is installed in the front of the sink bracket for easy setting and observation by operators.
Surface tension tester
conductivity meter
Programmable insulation withstand voltage tester
IIICamay Photovoltaic Module Wet Leakage Current Testing SystemBasic Description
Model:KM-PV-WL
The equipment of the wet leakage current test system complies withIEC 612152005TheIEC 616462008andIEC 61730-22004Standard specifications.
The equipment can freely set the heating range of the test liquid
Digital display of real-time temperature value
The equipment is equipped with a water level gauge that can directly observe the water level
4、 Specification for Wet Leakage Current Test System for Photovoltaic Modules
Experimental water tank:2100mm*1600mm*200mm
Heating sink:1200mm*600mm*500mm
Thermostatic water bath: constant water temperature22℃±3℃
Maximum detectable component2000mm*1500mm
This device is equipped with10Meter head submersible pump
Equipment weight: approximately150kg
Power requirement: single-phaseAC220V±5% 25A
Liquid resistivity:< 3500. Omega. cm
Spray pressure:34.5kpa
5、 Technical specifications of wet leakage current test system for photovoltaic modules
Testing method: Platinum plate method
Operation mode: fully automatic operation
Test scope:0-199mN/m
Measurement resolution:0.1mN/m(Note: Resolution alone does not mean that this value can be measured)
Measurement accuracy:0.2mN/m(Standard error value of platinum plate method)
Temperature range: Room temperature (if temperature control is required, a constant temperature bath and a constant temperature sample bath must be equipped)2A component)
Container capacity: minimum15mL
Voltage: StandardAC220V1A
6、 Quality Assurance of Wet Leakage Current Test System for Photovoltaic Modules
On site installation and debugging of equipment, and training of operating personnel for customers.
If the product cannot function properly due to manufacturing quality issues within twelve months from the date of shipment, provided that the user complies with the product installation and usage rules, our company will provide free repairs for the user.
For products outside the warranty period, our company provides long-term technical services.
After sales service response time:24Respond within hours.