-
E-mail
mk@lubex.com.cn
-
Phone
18922417705
-
Address
2203, the Pearl River International Building, No. 112, Yuehua Road, Yuexiu District, Guangzhou
Guangzhou Lvbaicao Scientific Instrument Co., Ltd
mk@lubex.com.cn
18922417705
2203, the Pearl River International Building, No. 112, Yuehua Road, Yuexiu District, Guangzhou
PerkinElmer multi-element standard solution 3125ml/bottleN9300233 multi-element standard solution 3 (100 μ g/mL) for AAS/ICP calibration
PerkinElmer N9300233 multi-element standard solution 3, containing 16 heavy metals at 100 μ g/mL, 125 mL/bottle, traceable to NIST, suitable for AAS/ICP-OES/ICP-MS calibration. Guangzhou Lvbaicao is an authorized agent of PerkinElmer.

PerkinElmer multi-element standard solution 3125ml/bottle Basic information of N9300233——
Item number: N9300233
Product Name: Multi Element Standard Solution 3
Product type: Calibration standard substance for spectral/mass spectrometry analysis
Element composition: Al (aluminum), As (arsenic), Ba (barium), Be (beryllium), Cd (cadmium), Co (cobalt), Cr (chromium), Cu (copper), Fe (iron), Mn (manganese), Ni (nickel), Pb (lead), Se (selenium), Sr (strontium), V (vanadium), Zn (zinc) (16 elements are clearly labeled)
Concentration specification: The concentration of each element is 100 μ g/mL
Solvent matrix: 2% HNO ∝ (nitric acid) aqueous solution (low impurities, no additional additives)
Packaging specification: 125 mL/bottle
Compatible instruments: PerkinElmer AAS (Atomic Absorption Spectrometer), ICP-OES (Inductively Coupled Plasma Emission Spectrometer), ICP-MS (Inductively Coupled Plasma Mass Spectrometer)
Product features: Complies with NIST traceable standards, batch numbers are traceable, concentration uniformity and stability meet standards
PerkinElmerN9300233Multi element standard solution 3125ml/bottleTechnological advantages——
The concentration is precise and traceable to NIST standards, and the calibration data is reliable to ensure the accuracy of the detection results;
16 elements are compatible with the matrix, with no interference or precipitation between elements, suitable for simultaneous detection of multiple elements;
2% nitric acid matrix effectively prevents element adsorption/hydrolysis and extends the shelf life of the solution;
Aseptic filling, with impurity content below the detection limit, to avoid calibration background interference.
PerkinElmerN9300233Multi element standard solution 3125ml/bottleApplication Introduction——
Used for daily calibration, linearity verification, sensitivity tuning, and drift correction of AAS, ICP-OES, and ICP-MS instruments;
QA/QC and method validation in areas such as environmental monitoring (water quality/soil heavy metal detection), food and drug safety (harmful element detection), material analysis (impurity quantification), etc.
PerkinElmer's related products——
Item NumberProduct Name
N9300234Multi Element Standard Solution 4
N9300101Single Element Standard Solution (Pb, 1000 μ g/mL)
N9300232Multi Element Standard Solution 2
N8145051NexION Setup Solution, 1 μ g/L, 500 mL (NexION tuning solution, 1 μ g/L, 500 mL)
N9300122Single Element Standard Solution (Cd, 1000 μ g/mL)
PerkinElmerPerkin ElmerN9300233 multi-element standard solution 3 (100 μ g/mL,125ml/bottle)Related issues for AAS/ICP calibration——
Q: Can N9300233 be directly used for ICP-MS low concentration (such as 1 μ g/mL) detection calibration?
Not for direct use, it needs to be diluted with 2% nitric acid to the target concentration. A large volume of 125mL can meet the needs of multiple dilutions, and it is recommended to complete calibration within 24 hours after dilution.
Q: What are the storage requirements for this standard solution?
It needs to be sealed, away from light, and placed in a cool and dry environment at 4-25 ℃, avoiding direct sunlight and high temperatures. The unopened shelf life is 12 months (based on the expiration date of the bottle).
Q: What is the main difference between N9300233 and N9300234 (multi-element standard solution 4)?
The core difference lies in the different composition of elements (the annotated list of included elements varies), which cover different testing project requirements. The corresponding model needs to be selected based on the actual tested elements.
PerkinElmer is a provider of scientific instruments and services, focusing on the field of analytical science. The professional quality of chromatography, spectroscopy technology, and consumables is highly recognized.
In the field of chromatographic and spectroscopic consumables, its products cover gas chromatography (GC), liquid chromatography (LC), and sample pretreatment consumables. These consumables comply with international standards such as USP/EP, GLP/GMP, and have strong batch consistency, ensuring accurate and compliant experimental data.
Guangzhou Lvbaicao is an authorized agent of PerkinElmer, providing genuine supply and technical support of PerkinElmer chromatographic consumables for customers in the fields of food, pharmaceuticals, environmental testing, etc.

