Pegasor portable particle counter from Finland

NegotiableUpdate on 12/28
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Finnish Pegasor portable particle counter PPC is a portable particle counter designed for measuring the concentration of ultrafine particles in engine exhaust and other combustion emission sources. PPC was originally designed for the European New Periodic Technical Inspection (nPTI) application and meets the measurement requirements for the quantity and concentration of particulate matter in vehicle exhaust specified in all European nPTI regulations. The newly updated and upgraded PPC system includes additional features that make it very suitable for any ultrafine particulate matter emission monitoring application, with improved features including particle quantity concentration.
Product Details


Pegasor portable particle counter from FinlandOverview

Pegasor portable particle counter from FinlandPPC is a portable particle counter used for measuring the concentration of ultrafine particulate matter in engine exhaust and other combustion emission sources,

PPC was originally designed for the application of New Periodic Technical Inspection (nPTI) in Europe,

It meets the measurement requirements for particulate matter concentration in vehicle exhaust specified in all European nPTI regulations.

The newly updated and upgraded PPC system includes additional features, making it highly suitable for any ultra-fine particulate matter emission monitoring application,

The improved features include particle number concentration (PN), particle mass concentration (PM), lung deposition surface area (LDSA), and particle size.

The fastest measurement frequency of 10Hz and several data communication options. The entire instrument is easy to operate and has low maintenance costs, even in harsh environments,

Reliable results can also be obtained.

Application field

The portable particle counter PPC provides a comprehensive and user-friendly solution for measuring ultrafine particles in various applications, with typical applications as follows:

New Periodic Technical Inspection (nPTI) measurement supervision

Operational verification of particulate matter trap DPF

Actual driving emissions (RDE) and PEMS measurement

Aircraft emission monitoring

Typical advantages

Measurement of ultrafine particle number concentration (PN), lung deposition surface area (LDSA), and particle mass concentration (PM)

Measurement of median particle size

Non collection measurement methods ensure longer maintenance intervals

No consumables, no working fluid

Multiple data communication options

Extensive self diagnostic system to improve measurement reliability

Not sensitive to vibration

Wide concentration range

The sensor module is heated to 200 ℃ to prevent condensation

Equipped with a heated sampling pipeline for sample gas transmission

Integrated VPR (volatile particle remover) for removing volatile particles

No need for dilution measurement, higher sensitivity

Integrated jet pump for sensor operation, no external air pump or compressor required

Measuring principle

The Finnish Pekkasol PPC is a portable device used to measure the concentration of ultrafine particles in the air of emission sources such as engine exhaust pipes or combustion processes.

PPC is equipped with a sturdy, durable, and low maintenance PPS-G2 sensor that can detect particle quantity, particle mass, and LDSA concentration,

And the median size of particulate matter. The PPS-G2 sensor combines a jet pump and a diffusion charger through an integrated VPR

After the volatile particle remover, the sample particles are charged in an ionized air driven injector, and after ionization, the electrostatic trap removes excess ions,

Simultaneously utilizing the electric mobility of particles for rapid sizing. When particles leave the sensor, their current is measured by a sensitive electrostatic meter,

This combination of current and size information can accurately determine the quantity, mass, and LDSA concentration of particulate matter.

Technical Specifications

Concentration range: Particle number (PN): 0~100000000 #/cm ³

Particle mass (PM): 0~80000 μ g/cm ³

Lung Deposition Surface Area (LDSA): 0-6500 μ m3/cm ³

Particle size range: 10~300 nm (for PM and Dp)

10 nm~1 μ m (for PN and LDSA)

Sensitivity: 30~1500 #/cm ³ (depending on sampling frequency and average)

Response time: 0.2 seconds

Sampling frequency: 10 Hz, 1 Hz, or 1 min

Sample gas flow rate: 5.5 liters per minute

Voltage: 100~260 VAC/50~60 Hz

Power consumption: 140 W (steady state), 1200 W (startup)

Environmental temperature: 5-40 ℃

Sampling conditions: Sample gas temperature: 200 ° C (standard), up to a maximum of 600 ° C

Sample gas pressure: atmospheric pressure ± 50 mbar (standard configuration)

Dew point:<85 ℃

Data communication: Bluetooth, serial port to USB

Dimensions: Width 464mm x Depth 175mm x Height 339mm

Weight: 9.1 kg (excluding heating pipeline)