Packaging residue gas chromatograph

NegotiableUpdate on 12/29
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The GC900C series of packaging residue gas chromatographs is a computerized, high-performance, and multi-purpose intelligent gas chromatograph designed and produced by our company to meet the requirements of a wide range of chromatographic users. Multiple detector combinations can be selected according to needs to meet the requirements of ordinary laboratories, daily production, routine testing, and trace and trace analysis. It is widely used in various fields such as petroleum, chemical, pesticide, environmental protection, epidemic prevention, medicine, electricity, scientific research, and education.
Product Details

Packaging residue gas chromatographGC900C seriesIt is a computerized, high-performance, and multi-purpose intelligent gas chromatograph designed and produced by our company to meet the requirements of a wide range of chromatographic users. Multiple detector combinations can be selected according to the needs to meet the requirements of ordinary laboratories, daily production, routine detection, and trace and trace analysis. It is widely used in various fields such as petroleum, chemical, pesticide, environmental protection, epidemic prevention, medicine, electricity, scientific research, and education.

Packaging residue gas chromatographPerformance characteristics:

1. Excellent column box performance, can achieve true near room temperature operation, can perform five step programmed heating, has column box automatic cooling and rear door opening function, fast cooling speed, and achieves rapid cooling.

2. It has six independent control areas: column box, capillary injector, packed column injector, detector, thermal conductivity cell, and auxiliary device.

3. The instrument is equipped with one capillary injection port and two packed column injection ports, which can simultaneously accommodate two gas path systems: packed column and capillary column. It can meet the current requirements for the selection and analysis of various chromatographic columns in chromatographic analysis.

4. The instrument has a dual gas path, triple injector, and dual packed column system structure, which can effectively suppress baseline fluctuations and drift in real time and is suitable for programmed temperature analysis.

5. The keyboard is used to set various control and usage parameters (including detector operation parameters), and the machine has functions such as self diagnosis, power-off protection, file storage and retrieval, and extreme temperature setting. It can display various temperature control settings, actual values, TCD bridge current, FID amplifier sensitivity, retention and analysis time, etc.

6. Multiple detector combinations can be selected according to usage requirements: FID, TCD, FPD, ECD, NPD, etc.

7. Adopting LCD display, the display content is rich, intuitive, and easy to operate.

8. Selecting domestic and foreign electrical components and carefully selecting them, along with calibrated pneumatic control valves, ensures the reliability, stability, and high sensitivity of the instrument.

Technical Indicators:

◆ Temperature control:

Temperature control range: 6 ℃ -400 ℃ at room temperature

Temperature control accuracy: Soil 0.01 ℃

Temperature control channels: 5 channels (expandable to 6 channels)

Program heating order: 5 orders

Cheng Sheng rate: 0.1 ℃ -50 ℃/min

Time setting: 0-9999.9/min

Flame ionization detector (FID): (n-hexadecane)

Detection limit: Mt ≤ 5 × 10-12g/s

Baseline noise: ≤ 6 × 10-14A

Baseline drift: ≤ 6 × 10-13A/h

Linear range: ≥ 106

Thermal conductivity detector (TCD): (n-hexadecane)

Sensitivity: S ≥ 5000mv.ml/mg

Baseline noise: ≤ 20UV

Baseline drift: ≤ 30UV/h

Linear range: ≥ 104