-
E-mail
2316332107@qq.com
-
Phone
15965217685
-
Address
Dezhou Technology Development Zone, Shandong Province
Shandong Pengkun Air Conditioning Equipment Co., Ltd
2316332107@qq.com
15965217685
Dezhou Technology Development Zone, Shandong Province
PYF-1Main functions of smoke exhaust valve ▪ characteristic ① Used in smoke exhaust systems, usually in a normally closed state ② During a fire smoke exhaust, the control center opens the DC24V electric valve or manually opens the valve on site, and outputs an action signal to interlock and start the smoke exhaust fan ③ Manual reset Main technical parameters ① Operating voltage: DC24V ② Action current: ≤ 0.7A Valve structure Main components: valve body, blades, shaft, shaft sleeve, actuator Schematic diagram of electrical wiring principle Explanation: (1) and (2) are DC24V power supplies, and (1) is the (+) pole (2) (3) is the valve action signal (4) (5) is the interlocking control line (normally closed, passive) (5) (6) is the interlocking control line (normally open, passive) PYF-1Smoke exhaust valveInstallation and precautions: 1Before installing the valve body, check whether the valve frame and operating mechanism are intact, whether the action is flexible, and confirm that all aspects of the valve are normal before installation. 2Before installing the valve body, attention should be paid to leaving a space around the valve, especially on the side where the valve operating mechanism is located. Generally, a clear space of no less than 350 mm should be left for regular operation experiments and inspections. 3When installing valves in the ceiling, inspection door holes should be provided below the observation and operation mechanism, with a general size of not less than 450 × 450mm. If conditions are limited, the ceiling inspection holes can also be reduced to 400 × 400mm. 4Before installation or during use after installation, valves should undergo regular opening and closing action tests. It is recommended to conduct them every six months to one year and keep records. The action experiment includes: whether the electric opening and closing are flexible; Whether the fire damper and smoke exhaust valve are operated by electrical signals or manually, and the output of electrical signals after operation. 5Do not apply any other external force to the valve. It is advisable to have separate supports and hangers to avoid deformation of the valve under the influence of external forces, which may affect its operational function. 6Electrical circuits and remote control steel cables should use ordinary plastic pipes of Dg20 as protective sleeves. The bending radius of the steel cable sleeve should not be less than 250 mm, and there should generally be no more than 3 bends. The length of the steel cable should generally not exceed 6m. If the length exceeds 6m, additional instructions should be provided when ordering. )When conditions permit, it is generally advisable to use close range control.






