Specifications | |
External dimensions(W*D*H) |
520×660×1161 (mm)PHCBI high-pressure sterilization potMLS-830L |
Inner diameter of the cavity(diameter*depth) |
φ370*750mm,convenientDiameter of the inner cavity for storing and retrieving items |
External material |
ABSResin high strengthExterior cover,double-sidedgalvanized steelboard,surfacespraypaintplaceStrong corrosion resistance |
Tank material |
thickness3mm corrosion-resistant stainless steelSurface mirror treatment to increase thermal radiation effect and improve heating speed |
Tank lid mechanism |
Manually open and close up and down,Security locking mechanism,Automatic locking during device operation |
Steam water connection plate |
Prevent steam droplets from leaking into the box when opening the lid |
effective volume |
80L |
weight |
about125kg |
device switch |
Equipped with leakage protection function,Automatically cut off power supply in case of leakage |
exhaust valve |
solenoid valveTwo:Fully open for use,Slowly open with each1,Reduce liquid splashing caused by pressure during liquid sterilization |
safety valve |
Spring fully open safety valve, exceedingmaximum pressure0Automatic operation at. 255Mpa,comply withYY 0154 standard |
sensor interface |
Internal temperature sensor interface,pressure gauge connectionIt can output pressure and temperature simultaneously to ensure the correspondence between pressure and temperature. Sample temperature sensor interface (optional) |
cooling method |
Optional natural cooling and forced cooling fansCooling, the forced cooling time is reduced by more than half compared to other models, even in other modes, as long as At saturated steam temperature-When the temperature is below 2 ℃, the fan blades will move,arrive60℃ When the fan stops running.The forced cooling button can be set at any time before or during operation.121℃-Only 100 ℃ is needed3min |
pressure gauge |
00.4Mpa,precision1Level 6,Installed in front for easy confirmation |
Maximum operating pressure |
0.255Mpa |
Operation control panel |
7-inch ultra large touch screen, even wearing gloves, can easily set temperature and time, and display operation functions |
power supply |
AC220V 50HZ,14A |
environmental conditions |
temperature5-40℃,relative humidity:≤85%Air pressure: 70kpa~ 106kpa, altitude3Below 000m Meets industry standards for medical devices |
Built in cooling water tank |
large capacity5L water tankReduce the frequency of cooling water treatment.Accessory mufflerreduceNoise during exhaust.The external observation window can confirm the water level at any time |
Internal water injection volume |
≥6.5L,Support long-term sterilization and multiple sterilization |
|
Container bottom drain standardfilter,Prevent foreign objects and impurities from entering and blocking |
caster |
4, with locking function |
performance parameters | |
|
Place a heating baffle on the ground inside the cylinder,Protect the heater and sensorThe highest water level,水位表示 |
Heater type |
Stainless steel heating tube 1500W×2 |
Heater circuit control |
solid state relay,Pulse control output |
sensor |
PT100 thermistor |
temperature range |
utensil,Liquid sterilization engineering:105℃~135℃ Dissolving Engineering:60℃~110℃ Thermal insulation engineering:45℃~60℃ preheating temperature:45℃~80℃ |
temperature control |
microcomputerPID controlPHCBI high-pressure sterilization potMLS-830L |
Setting and display mode |
Use the up and down keys,Digital display setting method,minimum resolution0.1℃ |
|
1. Time mode:0000-23:5Within the range of 91 is set as a unit and defaults to the current day. 2. date·Time mode:Set unit year month day hour minute,0000-23:5Within the range of 9,The resolution is1 point. |
timing·Timing decomposition function |
1. Set time:1 point~99 hours59 points,resolution:1 point 2. Set time:100 hours~999 hours,resolution:1 hour |
|
In maintenance mode, for buttons other than the 'start stop' buttonLock keys on the keyboardAnd the operation of release to prevent misoperation during operation |
|
Can be preheated in advance45℃~80℃Shortened the sterilization delay time10-20min |
memory function |
Each mode has three memory units that can store and remember temperature, time, forced cooling, etc. Save at most12 memory programs,Each program can change its name |
Fault recording function |
Can be recorded based on year, month, and day20 faults and their types |
accumulatesterilization/Number of times/time |
Users can check and grasp the operation status of the device at any time |
Temperature measurement function for sterilized items |
Temperature measurement, sterilization, and dissolution time timing using item sensors (optional) |
Data transmission function |
Timing output,alarm output,RS485communication functionTemperature output |
reportPolice and safety parameters | |
Alarm content |
Sensor abnormality,Relay short circuit,Heater disconnection,Abnormal lid lock,Abnormal drainage switch,The sensor for the sample is disconnected,Abnormal exhaust valve,Abnormal empty burning,Abnormal temperature riseThe safety valve is abnormal. |
Accessories and Optional Parts | |
accessory |
3aφ332D195.5basket,1M silicone drainage pipe,extinguishfungustestcard1 set (3)0Zhang)Steam water cup1, 1 cooling water tank, addhotdeviceblockboard1,filterblock1, huggate1 piece,Long arm clamp1 piece |
Optional accessories |
Item temperature sensor, can temperature testing sensor, recorder, temperature output terminal(4-20mA),External alarm output terminal,Time has reached the output terminal,Standard basket,Elevated lifting basket |
other | |
industry standard |
The cylinder body manufacturing complies withGB150-2011 standard. Product execution standards:YY/T 1007-2018 |
Manufacturer's warranty |
After equipment installation15 years |
Calibration service,3Q certification |
Having calibration and3Q certification professional qualifications |
Application for Pressure Vessel Use License |
Corresponding to the application standards for pressure vessels in various regions |