Functional Features |
Provide LCD display and local data query;
High precision real-time measurement of electrical parameters such as three-phase voltage, current, power, power factor, frequency, voltage current imbalance, voltage phase angle, and average voltage current;
Measure the 2-31st harmonic distortion rate of three-phase voltage and current (optional);
2-31st harmonic components, voltage and current K factor;
Measure positive and negative active and reactive energy data;
Supports RS-485 communication, Modbus-RTU、 645-2007 Dual Protocol;
Pulse output (active pulse, reactive pulse optional);
Programmable setting of current voltage ratio;
Easy installation, simple wiring, and small engineering quantity;
Multiple appearance options to meet the requirements of different cabinet electrical circuits.
|
Technical indicators |
| measurement accuracy | Active energy: 0.5S level, 1 level, 0.2S level |
| Reactive power: Level 1, Level 2 | |
| input parameter | Wiring methods: single-phase, three-phase three wire, three-phase four wire |
Rated voltage: AC 57.7V, AC100V, AC220VAC380V (can be customized according to requirements) | |
| Rated current: AC1A, AC5A | |
|
Overload: Voltage: 1.2 times (continuous), 2 times/1 second (instantaneous) Current: 1.2 times (continuous), 10 times/5 seconds (instantaneous) | |
| Frequency: 45~65Hz (conventional 50Hz, 60Hz) | |
| Working power supply | Scope of work: AC/DC 80V~270V |
| Power consumption:<5VA | |
| environment | Normal operating temperature: -25 ℃ to+55 ℃ |
| Extreme working temperature: -40 ℃ to+70 ℃ | |
| Storage and transportation temperature: -40 ℃ to+70 ℃ | |
| Storage and working humidity: ≤ 85%, non corrosive gas environment | |
| Atmospheric pressure: 80Kpa to 110Kpa | |
| Altitude: ≤ 5000m | |
| secure | Insulation resistance:>100M Ω |
| AC withstand voltage: AC 2kV | |
| functional module | Communication interface: RS-485 communication, Modbus RTU protocol,Baud rate 1200~19200bps, default 2400bps |
| mechanical parameters | Frame size (mm): 96 × 96; |
| Hole size (mm): 91 × 91; |

|
Product Outline Dimensional Drawing |

|
Product standards |
GB/T 17215.321 "Special Requirements for AC Measuring Equipment Part 21 Static Active Energy Meters (Class 1 and Class 2)"
GB/T 17215.322 "Special Requirements for AC Measuring Equipment Part 22 Static Active Energy Meters (0.2S and 0.5S Levels)"
GB/T 17215.323 "Special Requirements for AC Measuring Equipment Part 23: Static Reactive Energy Meters of Class 2 and Class 3"
GB/T 22264.1 "Installed digital display electrical measuring instruments - Part 1: Definitions and general requirements"
GB/T 22264.2 "Installed digital display electrical measuring instruments - Part 2: Special requirements for ammeters and voltmeters"
GB/T 22264.3 "Installed digital display electrical measuring instruments - Part 3: Special requirements for power meters and reactive power meters"
GB/T 22264.7 "Installed digital display electrical measuring instruments - Part 7: Special requirements for multifunctional instruments"
GB/T 22264.8 "Installed digital display electrical measuring instruments - Part 8: Recommended test methods"