PACON 4900 Online Phenol Phthalein Alkalinity Analyzer

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

PACON 4900 Online Phenol Phthalein Alkalinity Analyzer is a compact, easy to operate, and precise online analyzer provided by JENSPRIMA, used for automatic online detection of phenol Phthalein alkalinity and quality control of boiler water. The principle of titration color change method is to measure high/low range by selecting different reagents. Low maintenance and low reagent consumption, capable of long-term continuous operation. Standard 4-20mA and RS485 Modbus outputs can be easily integrated into your existing control system.

Product Details

PACON 4900 Online Phenol Phthalein Alkalinity Analyzer

measurement parameters:Phenol Fen Phthalide Alkalinity (p-value)

Typical Applications:Boiler feedwater, boiler water cooling water

PACON 4900在线酚fen酞碱度分析仪



Characteristics of PACON 4900 Online Phenol Phthalein Alkalinity Analyzer


Durable and precise analyzer method (titration color change)

● Automatic online monitoring, requiring only one reagent Special material measuring groove, condensation water will not adhere to optical components Stable measurement, generally does not require calibration 4-20mA/RS485 Modbus output ● 4-channel programmable relay output ● External signal input function (can be linked with external devices) ● Compact design, easy to install Low maintenance and low reagent consumption




specification


Selected reagent: TP5050 TP5200

Measurement range: 0.2-5mmol/L 0.8-20mmol/L Accuracy: ± 5% of the maximum value of the selected reagent Repeatability: ± 2.5% of the maximum value of the selected reagent Measurement method: titration color change method Reagent consumption: 0.05-0.6ml/analysis per session Reagent expiration date: 2 years from factory Analysis time: about 3 minutes, depending on the concentration of phenolphthalein alkalinity and the set flushing time Measurement interval: 5-360min optional Automatic cleaning: The instrument will automatically clean after each measurement Calibration: Manual calibration of service menu Environmental temperature: 10-45 ℃ Water sample temperature: 5-40 ℃ Water sample pressure: 0.5-5bar, recommended 1-2bar Water quality requirements: clear, colorless, no suspended solids, no bubbles, pH>8.2 Power supply: 100-240VAC, 50/60Hz Power consumption: 20W (working), 3.5W (standby) Inlet/outlet: 6mm hose, with open outlet and no back pressure discharge Current output: 0/4-20mA Relay output: 4-channel passive NC/NO relay output, 250VAC/1A External input: 2-channel programmable input contacts Protection level: IP65 Size: 300 x 300 x 200mm

Weight: ca. 4Kg