P-BP1000 Groundwater Low Speed Sampling and Well Cleaning Analysis System

NegotiableUpdate on 12/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
P-BP1000 Groundwater Low speed Sampling and Well Cleaning Analysis System Low speed sampling is a method of extracting groundwater samples from wells at a low flow rate (flow rate controlled between 100-500mL/min, water level drop not exceeding 10cm), which can minimize the volatilization of pollutants and the amount of wastewater generated.
Product Details

P-BP1000Groundwater low-speed sampling and well washing analysis systemProduct Introduction

Low speed sampling is a method of extracting groundwater samples from a well at a low flow rate, where the flow rate is controlled within a certain range 100-500mL/min, The water level drop should not exceed 10cm, which can minimize the volatilization of pollutants and the amount of wastewater generated. Geotech on-site low-speed sampling system and VuSitu ™ Mobile applications minimize errors, save time, and improve low flow sampling efficiencycostAnd it can generate reliable reports.

The low-speed sampling and well washing analysis system for groundwater should be developed by Geotech low-speed sampling equipment (airbag pump)Multi parameter analysis equipment (including low-speed sampling analysis software)andWater level drop control equipmentComposition, this system can be used in VuSitu ™ Under the guidance of software, complete low-speed well flushing work and select appropriate sampling timing. While sampling, multi parameter analysis equipment can perform real-time routine parameter analysis on the collected samples to obtain reliable water quality data.

P-BP1000Groundwater low-speed sampling and well washing analysis systemProduct technical advantages

Low speed well flushing and sampling of groundwater is different from traditional well flushing and sampling. Low speed well flushing and sampling is a new method that does not require extracting a large amount of water from the well. Groundwater with low flow rate (flow rate controlled within) 100-500mL/min, Pump water from the well screen (with a water level drop not exceeding 10cm), and only extract the sampling area rather than the entire well volume. This method minimizes the disturbance of water and the impact on the well and surrounding strata during the well washing and sampling process, reducing the sample's impactturbidity.

Compared with traditional methods, low-speed well flushing and sampling methods for groundwater have the following advantages:

Improving sample quality through low-speed well washing and sampling methods can reduce turbidity and minimize volatilization. Because turbidity no longer interferes with the determination of physical and chemical indicators, there is no need for sample filtration steps, further reducing sampling and analysis costs.

Improve sample accuracy and precision, enabling users to accurately determine the true trend of geochemistry, avoiding unnecessary costs of supervision and repeated sampling to prevent sample contamination.

A simpler and cheaper sampling system, which is more economical and convenient compared to traditional well flushing and sampling with high flow rates.

Extending the service life of a well by reducing sediment flow into the well through low flow rates, prolonging the service life of the well, and reducing the need for well maintenance.

Low speed groundwater flushing and sampling equipment

Geotech airbag pump, is a low flow rate, low disturbance groundwater flushing and sampling equipment, suitable for various types, especiallyVOC Collection of class pollutant samples.

The airbag pump controller is equipped with a small air compressor that provides compressed air to meet the needs ofStill water levelWithin 60 metersRequirements for operating conditions. If the water level is deepA booster controller can be installed to enable the airbag pump to operate at depths of up to Sampling is conducted below a liquid level of 300 meters. To achieve a deeper sampling depth, the airbag pump can also be equipped with a drop pipe component to allow deeper groundwater samples to enter the airbag pump. In order to ensure low disturbance to groundwater, the airbag pump can also choose a drop probe. When the groundwater level settles too much during the sampling process, the sampling can be automatically stopped and wait for the water level to recover.

Technical parameters of pump body

Technical parameters of pump body


1.66”×36”Portable


1.66”×18”Portable

0.85 portable









Pump body


316 stainless steel


316 stainless steel

316 stainless steel









Pump bottom


316 stainless steel


316 stainless steel

316 stainless steel









Airbag material


Polytetrafluoroethylene


Polytetrafluoroethylene

Polytetrafluoroethylene









outer diameter


4.2cm1.66 Inches)


4.2cm1.66 Inches)

2.2cm0.85 Inches)









Length (including filter screen)


101.6cm40 Inches)


48.3cm19 Inches)

47.3cm18 5/8Inches)









weight


2.3Kg5.0 Pound)


1.4Kg3.0 Pound)

0.5Kg1.1 Pound)









traffic/loop


310 mL (11 oz.)


150 mL (5 oz.)

29 mL (0.9 oz.)









Minimum inner diameter of monitoring well


5cm2 Inches)


5cm2 Inches)

2.5cm1 Inches)









Maximum operating pressure


6.9 bar (1 00 psi)


6.9 bar (1 00 psi)

6.9 bar (1 00 psi)









Minimum operating pressure


.3 bar (5 psi) ash*


.3 bar (5 psi) ash*

.3 bar (5 psi) ash*









Maximum sampling depth


61m200 Feet)


61m200 Feet)

61m200 Feet)









Straw size





.17' x .25'4mmx6mm


trachea


.17' x .25'4mmx6mm


.17' x .25'4mmx6mm


outlet pipe


.25' x .375' (6mmx10mm)


.25' x .375' (6mmx10mm)

.17' x .25'4mmx6mm


controller

Portable controller,A reliable ultra small compressor can operate from static water level inside 60 Collecting water samples at a distance of meters does not require dragging bulky, noisy compressors or dangerous nitrogen cylinders to the sampling site. Save time, energy, andcost.

Technical parameters of controller


Technical parameters of controller



power supply

12-14V DC power supply, @ 7.5A, 72-84W or 220V AC



Maximum work pressure

6.9 bar (100 psi) - set for safety reasons



operating temperature

10°C-40°C (50°F-104°F)



time

Exhaust:1.8-60s, Inflation: 1.8-60s



trachea/Water outlet pipe interface

0.6 cm outer diameter push-pull tube joint. 1/8 inch hook, can be connected to other accessories



size

28.96 cm in length x 12.92 cm in width x 17.02 cm in height



weight

4kg

Water level drop control unit

Water level drop unit,Controller combined with water level drop unit can achieve low flow rate samplingControl of water level drop during the process.

Technical parameters of water level drop control equipment




Technical parameters of water level drop control equipment





size



ET 卷盘 33 cm X 28cm X 17.8cm(H X W XD)





probe



1.6cm X 15.6cm(OD X ID)





Length and weight



ET type 60m=5kg





accuracy



3mm





material



Polypropylene and aluminum(ET), Measuring ruler: steel with polyethylene coating; Probe: Teflon and stainless steel





power supply



9-volt DC alkaline battery





instruction



Sound and light indication





Connection method with controller



Leakage control module interface





certification



CE Certification

Multi parameter analysis equipment

The AT500 multi parameter water quality analysis device is a portable and intelligent water quality data acquisition device designed to monitor water level (water pressure), temperature, atmospheric pressure, and other parameters in the field environment pH/ORP、 Measurement of water temperature, conductivity, salinity, turbidity, RDO optical dissolved oxygen, TDS total dissolved solids, resistivity, density, ion selective electrode and other data.

The LCD screen of this instrument can clearly display the overall status of the device, battery life, data recording, sensor status, and connections. By applying toThe VuSit mobile app for Android devices is convenient for setting up programs and on-site operation. Users can use the VuSit mobile app to send data from their Android devices via email, record the data to a smartphone, or download the data directly to a computer by connecting to the app on their smartphone. Use GPS coordinates to locate the station and track it with pictures and instructions. Simplify calibration through automatic detection of calibration solution and automatic stabilization function.

Equipment Technical Parameters






Technical parameters of multi parameter equipment










Operating temperature




-5-50°C (23 -122°F)










Storage temperature




No liquid components: -40-65 ° C (-40-149 F) pH/ORP detector: -5-65 ° C










size




4.7 cm (1.86 inches) OD x 46 cm (18.145 inches) with current limiter installed (including connector)






With hanging ring:59 cm (23.25 inches)














weight




0.978 kg (3.2 lbs) - includes all sensors, batteries, and hanging rings.










Wetted materials (control head and sensor)




CeramicsDelrin ™ Polyformaldehyde resin Inconel ™ Chromium nickel iron alloy, PC, PC alloy, platinum, polyamide






FiberSantoprene ™ Rubber, titanium Viton ™ Fluororubber.














Environmental protection level




IP68 comes with all sensors and cables. IP67 has removed sensors, battery covers, or cables










Maximum pressure level




reach, achieve, attain 350 PSI










output option




RS485/MODBUS,SDI-12, Bluetooth ®










Read level




each Read parameters every 2 seconds without erasing mode.










Record speed




1 minute to 99 hours










data recording




50 records (defined, planned, or stored)










LCD screen




The comprehensive display shows the detector, sensor ports, data recording, battery, and connection status.










External power 4 External power current 4




maximum 8-36 VDC, 275mA (not required) Sleep: 0.10mA standard






Measurement:15mA standard, 45mA maximum value



















Using Android 4.4. Use Win Situ 5 software on selected mobile devices with Bluetooth 2.0, VuSitu mobile



interface




move






APP application software.














cable




Breathable or non breathable polyurethane or breathable Tefzel ® Ethylene tetrafluoroethylene copolymer.










hex screwdriver




0.050 inches (1.3 mm)














Android: available on Purchase from Google Play App Store (Android 4.4 or above applications require Bluetooth)







2.0



software interface




Windows operating system: Win Situ 5







Data Services:HydroVu









Technical parameters of sensors



Flow pool specifications




size


6.4 cm (2.5 in.)Outer diameter,15.2 cm (6 in.)long




volume


125 mL(No probe)




material


Transparent polished polycarbonate




ground spike


316Lstainless steel




baseplate


12’’*12’’ PVC




NPT accessories


3/8”to 1/4”or 3/8”to 3/8”




pipe size


3/8”1/4”




traffic


0.1-0.5L/min




Suggested operational restrictions


traffic8.0 L/minPressure:30 psi






Specification of atmospheric pressure sensor




precision


±1mbar; Resolution±0.1 mbar




scope


300 to 1100 mbar




sensor type


fixed type




response time


T63<1s, T90<1s, T95<1s




unit of measurement


PSI, kPa, bar, mbar, mmHg, inHg




method


Silicon strain gauge





Specification of Salinity Sensor



scope

0-350 PSU



resolution

0.1 PSU



unit of measurement

PSU



method

standard method 2520A





precision





Reading of±0.5%+1 μS/cm 0-100,000 μS/cm;









Reading of±1.0% 100,000-200,000 μS/cm;

























scope





0-350,000 μS/cm

























resolution





0.1 µS/cm

























sensor type





portable
















scope





0-350 ppt

























resolution





0.1 ppt

























unit of measurement





ppt, ppm
















response time





T63<1s, T90<3s, T95<5s
















unit of measurement





Actual conductivity:μS/cm, mS/cm









Specific conductivity:μS/cm,mS/cm Salinity content:
























method





standard method 2510EPA 120.1






























Horizontal, depth, and pressure sensor specifications
















precision




standard ±0.1% Full range(FS





















Breathable or non breathable










9.0 m30 ft-Sudden pulse:27 m90 ft





scope





30 m100 ft-Sudden pulse:40 m130 ft



















76 m250 ft-Sudden pulse:107 m350 ft










200 m650 ft-Sudden pulse:229 m750 ft















resolution





±0.01% FSOr better
























sensor type





fixed type






















response time





T63<1s, T90<1s, T95<1s

























unit of measurement





Stress psi, kPa, bar, mbar, mmHg, inHg,









cmH2O, inH2O Levelmm, cm, m, in, ft,



















cmH2O, inH2O















method





Piezoelectric resistor; ceramics