-
E-mail
15765947@qq.com
-
Phone
18981947117
-
Address
No. 248 Jinfu Road, Jinniu District, Chengdu
Chengdu Ruixin Instrument Co., Ltd
15765947@qq.com
18981947117
No. 248 Jinfu Road, Jinniu District, Chengdu
P-BP1000Groundwater low-speed sampling and well washing analysis systemProduct Introduction
Low speed sampling is a method of extracting groundwater samples from a well at a low flow rate, where the flow rate is controlled within a certain range 100-500mL/min, The water level drop should not exceed 10cm, which can minimize the volatilization of pollutants and the amount of wastewater generated. Geotech on-site low-speed sampling system and VuSitu ™ Mobile applications minimize errors, save time, and improve low flow sampling efficiencycostAnd it can generate reliable reports.
The low-speed sampling and well washing analysis system for groundwater should be developed by Geotech low-speed sampling equipment (airbag pump),Multi parameter analysis equipment (including low-speed sampling analysis software)andWater level drop control equipmentComposition, this system can be used in VuSitu ™ Under the guidance of software, complete low-speed well flushing work and select appropriate sampling timing. While sampling, multi parameter analysis equipment can perform real-time routine parameter analysis on the collected samples to obtain reliable water quality data.
P-BP1000Groundwater low-speed sampling and well washing analysis systemProduct technical advantages
Low speed well flushing and sampling of groundwater is different from traditional well flushing and sampling. Low speed well flushing and sampling is a new method that does not require extracting a large amount of water from the well. Groundwater with low flow rate (flow rate controlled within) 100-500mL/min, Pump water from the well screen (with a water level drop not exceeding 10cm), and only extract the sampling area rather than the entire well volume. This method minimizes the disturbance of water and the impact on the well and surrounding strata during the well washing and sampling process, reducing the sample's impactturbidity.
Compared with traditional methods, low-speed well flushing and sampling methods for groundwater have the following advantages:
Improving sample quality through low-speed well washing and sampling methods can reduce turbidity and minimize volatilization. Because turbidity no longer interferes with the determination of physical and chemical indicators, there is no need for sample filtration steps, further reducing sampling and analysis costs.
Improve sample accuracy and precision, enabling users to accurately determine the true trend of geochemistry, avoiding unnecessary costs of supervision and repeated sampling to prevent sample contamination.
A simpler and cheaper sampling system, which is more economical and convenient compared to traditional well flushing and sampling with high flow rates.
Extending the service life of a well by reducing sediment flow into the well through low flow rates, prolonging the service life of the well, and reducing the need for well maintenance.
Low speed groundwater flushing and sampling equipment
Geotech airbag pump, is a low flow rate, low disturbance groundwater flushing and sampling equipment, suitable for various types, especiallyVOC Collection of class pollutant samples.
The airbag pump controller is equipped with a small air compressor that provides compressed air to meet the needs ofStill water levelWithin 60 metersRequirements for operating conditions. If the water level is deep,A booster controller can be installed to enable the airbag pump to operate at depths of up to Sampling is conducted below a liquid level of 300 meters. To achieve a deeper sampling depth, the airbag pump can also be equipped with a drop pipe component to allow deeper groundwater samples to enter the airbag pump. In order to ensure low disturbance to groundwater, the airbag pump can also choose a drop probe. When the groundwater level settles too much during the sampling process, the sampling can be automatically stopped and wait for the water level to recover.
Technical parameters of pump body
Technical parameters of pump body |
1.66”×36”Portable |
1.66”×18”Portable |
0.85 portable |
|||
Pump body |
316 stainless steel |
316 stainless steel |
316 stainless steel |
|||
Pump bottom |
316 stainless steel |
316 stainless steel |
316 stainless steel |
|||
Airbag material |
Polytetrafluoroethylene |
Polytetrafluoroethylene |
Polytetrafluoroethylene |
|||
outer diameter |
4.2cm(1.66 Inches) |
4.2cm(1.66 Inches) |
2.2cm(0.85 Inches) |
|||
Length (including filter screen) |
101.6cm(40 Inches) |
48.3cm(19 Inches) |
47.3cm(18 5/8Inches) |
|||
weight |
2.3Kg(5.0 Pound) |
1.4Kg(3.0 Pound) |
0.5Kg(1.1 Pound) |
|||
traffic/loop |
310 mL (11 oz.) |
150 mL (5 oz.) |
29 mL (0.9 oz.) |
|||
Minimum inner diameter of monitoring well |
5cm(2 Inches) |
5cm(2 Inches) |
2.5cm(1 Inches) |
|||
Maximum operating pressure |
6.9 bar (1 00 psi) |
6.9 bar (1 00 psi) |
6.9 bar (1 00 psi) |
|||
Minimum operating pressure |
.3 bar (5 psi) ash* |
.3 bar (5 psi) ash* |
.3 bar (5 psi) ash* |
|||
Maximum sampling depth |
61m(200 Feet) |
61m(200 Feet) |
61m(200 Feet) |
|||
Straw size |
.17' x .25'(4mmx6mm) |
|||||
trachea |
.17' x .25'(4mmx6mm) |
.17' x .25'(4mmx6mm) |
||||
outlet pipe |
.25' x .375' (6mmx10mm) |
.25' x .375' (6mmx10mm) |
.17' x .25'(4mmx6mm) |
controller
Portable controller,A reliable ultra small compressor can operate from static water level inside 60 Collecting water samples at a distance of meters does not require dragging bulky, noisy compressors or dangerous nitrogen cylinders to the sampling site. Save time, energy, andcost.
Technical parameters of controller
Technical parameters of controller |
|
power supply |
12-14V DC power supply, @ 7.5A, 72-84W or 220V AC |
Maximum work pressure |
6.9 bar (100 psi) - set for safety reasons |
operating temperature |
10°C-40°C (50°F-104°F) |
time |
Exhaust:1.8-60s, Inflation: 1.8-60s |
trachea/Water outlet pipe interface |
0.6 cm outer diameter push-pull tube joint. 1/8 inch hook, can be connected to other accessories |
size |
28.96 cm in length x 12.92 cm in width x 17.02 cm in height |
weight |
4kg |
Water level drop control unit
Water level drop unit,Controller combined with water level drop unit can achieve low flow rate samplingControl of water level drop during the process.
Technical parameters of water level drop control equipment
Technical parameters of water level drop control equipment |
|||
size |
ET 卷盘 33 cm X 28cm X 17.8cm(H X W XD) |
||
probe |
1.6cm X 15.6cm(OD X ID) |
||
Length and weight |
ET type 60m=5kg |
||
accuracy |
3mm |
||
material |
Polypropylene and aluminum(ET), Measuring ruler: steel with polyethylene coating; Probe: Teflon and stainless steel |
||
power supply |
9-volt DC alkaline battery |
||
instruction |
Sound and light indication |
||
Connection method with controller |
Leakage control module interface |
||
certification |
CE Certification |
Multi parameter analysis equipment
The AT500 multi parameter water quality analysis device is a portable and intelligent water quality data acquisition device designed to monitor water level (water pressure), temperature, atmospheric pressure, and other parameters in the field environment pH/ORP、 Measurement of water temperature, conductivity, salinity, turbidity, RDO optical dissolved oxygen, TDS total dissolved solids, resistivity, density, ion selective electrode and other data.
The LCD screen of this instrument can clearly display the overall status of the device, battery life, data recording, sensor status, and connections. By applying toThe VuSit mobile app for Android devices is convenient for setting up programs and on-site operation. Users can use the VuSit mobile app to send data from their Android devices via email, record the data to a smartphone, or download the data directly to a computer by connecting to the app on their smartphone. Use GPS coordinates to locate the station and track it with pictures and instructions. Simplify calibration through automatic detection of calibration solution and automatic stabilization function.
Equipment Technical Parameters
Technical parameters of multi parameter equipment |
||||||
Operating temperature |
-5-50°C (23 -122°F) |
|||||
Storage temperature |
No liquid components: -40-65 ° C (-40-149 F) pH/ORP detector: -5-65 ° C |
|||||
size |
4.7 cm (1.86 inches) OD x 46 cm (18.145 inches) with current limiter installed (including connector) |
|||||
With hanging ring:59 cm (23.25 inches) |
||||||
weight |
0.978 kg (3.2 lbs) - includes all sensors, batteries, and hanging rings. |
|||||
Wetted materials (control head and sensor) |
CeramicsDelrin ™ Polyformaldehyde resin Inconel ™ Chromium nickel iron alloy, PC, PC alloy, platinum, polyamide |
|||||
FiberSantoprene ™ Rubber, titanium Viton ™ Fluororubber. |
||||||
Environmental protection level |
IP68 comes with all sensors and cables. IP67 has removed sensors, battery covers, or cables |
|||||
Maximum pressure level |
reach, achieve, attain 350 PSI |
|||||
output option |
RS485/MODBUS,SDI-12, Bluetooth ® |
|||||
Read level |
each Read parameters every 2 seconds without erasing mode. |
|||||
Record speed |
1 minute to 99 hours |
|||||
data recording |
50 records (defined, planned, or stored) |
|||||
LCD screen |
The comprehensive display shows the detector, sensor ports, data recording, battery, and connection status. |
|||||
External power 4 External power current 4 |
maximum 8-36 VDC, 275mA (not required) Sleep: 0.10mA standard |
|||||
Measurement:15mA standard, 45mA maximum value |
||||||
Using Android 4.4. Use Win Situ 5 software on selected mobile devices with Bluetooth 2.0, VuSitu mobile |
||||||
interface |
move |
|||||
APP application software. |
||||||
cable |
Breathable or non breathable polyurethane or breathable Tefzel ® Ethylene tetrafluoroethylene copolymer. |
|||||
hex screwdriver |
0.050 inches (1.3 mm) |
|||||
Android: available on Purchase from Google Play App Store (Android 4.4 or above applications require Bluetooth) |
||||||
2.0 |
||||||
software interface |
Windows operating system: Win Situ 5 |
|||||
Data Services:HydroVu |
||||||
Technical parameters of sensors
Flow pool specifications |
||
size |
6.4 cm (2.5 in.)Outer diameter,15.2 cm (6 in.)long |
|
volume |
125 mL(No probe) |
|
material |
Transparent polished polycarbonate |
|
ground spike |
316Lstainless steel |
|
baseplate |
12’’*12’’ PVC |
|
NPT accessories |
3/8”to 1/4”or 3/8”to 3/8” |
|
pipe size |
3/8”,1/4” |
|
traffic |
0.1-0.5L/min |
|
Suggested operational restrictions |
traffic8.0 L/minPressure:30 psi |
|
Specification of atmospheric pressure sensor |
||
precision |
±1mbar; Resolution±0.1 mbar |
|
scope |
300 to 1100 mbar |
|
sensor type |
fixed type |
|
response time |
T63<1s, T90<1s, T95<1s |
|
unit of measurement |
PSI, kPa, bar, mbar, mmHg, inHg |
|
method |
Silicon strain gauge |
|
Specification of Salinity Sensor |
|
scope |
0-350 PSU |
resolution |
0.1 PSU |
unit of measurement |
PSU |
method |
standard method 2520A |
precision |
Reading of±0.5%+1 μS/cm 0-100,000 μS/cm; |
|||||||||
Reading of±1.0% 100,000-200,000 μS/cm; |
||||||||||
scope |
0-350,000 μS/cm |
|||||||||
resolution |
0.1 µS/cm |
|||||||||
sensor type |
portable |
|||||||||
scope |
0-350 ppt |
|||||||||
resolution |
0.1 ppt |
|||||||||
unit of measurement |
ppt, ppm |
|||||||||
response time |
T63<1s, T90<3s, T95<5s |
|||||||||
unit of measurement |
Actual conductivity:μS/cm, mS/cm |
|||||||||
Specific conductivity:μS/cm,mS/cm Salinity content: |
||||||||||
method |
standard method 2510,EPA 120.1 |
|||||||||
Horizontal, depth, and pressure sensor specifications |
||||||||||
precision |
standard ±0.1% Full range(FS) |
|||||||||
Breathable or non breathable |
||||||||||
9.0 m(30 ft)-Sudden pulse:27 m(90 ft) |
||||||||||
scope |
30 m(100 ft)-Sudden pulse:40 m(130 ft) |
|||||||||
76 m(250 ft)-Sudden pulse:107 m(350 ft) |
||||||||||
200 m(650 ft)-Sudden pulse:229 m(750 ft) |
||||||||||
resolution |
±0.01% FSOr better |
|||||||||
sensor type |
fixed type |
|||||||||
response time |
T63<1s, T90<1s, T95<1s |
|||||||||
unit of measurement |
Stress psi, kPa, bar, mbar, mmHg, inHg, |
|||||||||
cmH2O, inH2O Level:mm, cm, m, in, ft, |
||||||||||
cmH2O, inH2O |
||||||||||
method |
Piezoelectric resistor; ceramics |
|||||||||