Welcome Customer !

Membership

Help

Shenzhen Changlilai Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shenzhen Changlilai Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    Shenzhen headquarters address: Room 902, Donghongjing Building, No. 84 Dongfang 1st Road, Songgang Street, Bao'an District, Shenzhen

Contact Now

Optical sludge concentration meter turbidity controller

NegotiableUpdate on 05/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Manufacturer of optical sludge concentration meter, determination of turbidity controller for optical sludge concentration meter, introduction of foreign turbidity measurement technology, use of imported turbidity detection technology for liquid turbidity meter electrodes, applied in turbidity measurement occasions such as sewage treatment, sewage tanks, desulfurization towers, aeration tanks, pulp tanks, sedimentation tanks, etc.

Product Details

Optical sludge concentration meter turbidity controllerDetailed Introduction

Professional manufacturer of optical sludge concentration meter turbidity controller. Optical turbidity control instrument is used forMeasure turbidity,For example, urban sewage treatment (inlet and outlet control),Health Network,Industrial wastewater treatment,surface water monitoring,waterworks,And drinking water, etc.Optical turbidityThe instrument can be installed on the panel,Wall-mounted installation,Pipeline installation.Instrument provided2Circuit current output,The heavy load is500 Ω. The following are detailed specifications:

function

NTU/FNU

mg/L

measurement range

0.00 to 4000.00

0.00 to 4500.00

Measurement resolution

0.1

0.1

Measurement accuracy

<Read value5%

<Read value5%

Temperature compensation method

NTC

Temperature measurement range

0.0 to+50.0

Temperature resolution

0.1

Temperature accuracy

±0.2

Data update

each time1-60Adjustable in seconds

instrumentWorking environment temperature

0 to +70

instrumentStorage environment temperature

-20 to +70

display

Large backlit dot matrixLCD

turbiditycurrent output1

isolated4to20mAoutput,*Large load500Ω

Temperature current output2

isolated4to20mAoutput,*Large load500Ω

Accuracy of current output

±0.05 mA

RS485

Modbus RTUStandard agreement

Communication speed

9600/19200/38400

Relay contact capacity

5A/250VACThe5A/30VDC

Cleaning settings

ON1to1000In secondsOFF0.1to1000.0hour

A multifunctional relay

wash/Periodic alarm/false alarm

Relay delay action

0-120second

data recording

50Wan Bi

Language Selection

English/Traditional Chinese/Simplified Chinese

USBinterface

Record downloads and software updates(96The series does not have this function)

Protection level

IP65

power supply

90to260VAC,power consumption<5tile

Installation method

Panel installation/Wall-mounted installation/Pipeline installation

weight

144series0.85Kg, ninety-sixseries0.55Kg