Fluorescence method for measuring dissolved oxygen analyzer

NegotiableUpdate on 05/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The DO-702 fluorescence based dissolved oxygen online analyzer is an online analytical instrument widely used for continuous monitoring of dissolved oxygen, saturation, oxygen partial pressure, and temperature in solutions such as thermal power, metallurgy, environmental protection, pharmaceuticals, biochemistry, food, and tap water.

Product Details

Fluorescence method for measuring dissolved oxygen analyzerDetailed Introduction
DO-702 uses fluorescence method to measure dissolved oxygen. The emitted blue light shines on the fluorescent layer, and the fluorescent substance is excited to emit red light. The oxygen concentration is inversely proportional to the time it takes for the fluorescent substance to return to the ground state. There is no oxygen consumption during measurement, the data is stable, the performance is reliable, there is no interference, and the installation and calibration are simple. Humanized sensing of dissolved oxygen data measured by sensors.
Function:% saturation concentration
Measurement range: 0.0 to 400.0 0.00 to 40.00, 0.0 to 200.0 ug/L
Measurement resolution: 0.1 0.01/0.1
Measurement accuracy: ± 0.2 ± 0.02
Temperature compensation method: Pt-1000/NTC22K
Temperature measurement range: -10.0 to+130.0 ℃
Temperature compensation range: -10.0 to+130.0 ℃
Temperature resolution: 0.1 ℃
Temperature accuracy: ± 0.2 ℃
Electrode current measurement range: -2.0 to+400 nA
Electrode current measurement accuracy: ± 0.005nA
Polarization voltage: -0.675V
Pressure adjustment range: 500 to 9999mBar
Salinity compensation range: 0.00 to 50.00 ppt
Working environment temperature: 0 to+70 ℃
Storage environment temperature: -20 to+70 ℃
Display: Large backlit dot matrix LCD
Dissolved oxygen current output: 1 isolated 4 to 20mA output, * large load 500 Ω
Temperature current output: 2 isolated 4 to 20mA output, * large load 500 Ω
Current output accuracy: ± 0.05 mA
RS485 Modbus RTU Standard Protocol
Communication speed 9600/19200/38400
Relay contact capacity 5A/250VAC, 5A/30VDC
Cleaning setting ON: 1 to 1000 seconds, OFF: 0.1 to 1000.0 hours
One way multifunctional relay: cleaning/cycle alarm/error alarm
Relay delay action: 0-120 seconds
Data record: 500000 transactions
Language selection: English/Traditional Chinese/Simplified Chinese
USB interface: Record downloads and software updates (96 series does not have this feature)
Protection level: IP65
Power supply: 90 to 260VAC, power consumption<5 watts
Installation method: Panel installation/Wall mounted installation/Pipeline installation
Weight: 144 series 0.85kg, 96 series 0.55kg.