Online power frequency UPS and modular UPS (10KVA-1000KVA)
|
☆ Input power factor>0.95 ☆ Wide input voltage range (156V-280V/270V-485V) ☆ User friendly interface - large Chinese LCD display screen ☆ Multi machine parallel current sharing system ☆ Multi functional human-machine dialogue friendly interface and RS-232 communication interface ☆ Can be used for dual machine hot backup operation ☆ Acceptable 100% unbalanced load
|
|
|
|
|
Electrical Characteristics
|
|
Rated output KVA (PF=0.8)
|
10
|
15
|
22.5
|
30
|
40
|
50
|
60
|
80
|
90
|
100
|
125
|
150
|
160
|
200
|
250
|
300
|
400
|
|
input
|
|
Main circuit 1 voltage
|
190.508.200.380.415.440.480V+/-15% or 20% 3P 4W or 3P 3W+G
|
|
Main circuit 2 voltage
|
190/110.200/115.208/10.220/127.380/220.440/227+/-15% or 20% 3P 4W or 3P 3W+G
|
|
frequency
|
50 or 60Hz+/-5%
|
|
output
|
|
steady-state voltage
|
190/110.200/115.208/10.220/127.380/220.440/254.480/227+/-1% 3P 4W or 3P 3W+G (+/-10% adjustable)
|
|
Transient voltage
|
Load variation from 0% to 100% and from 100% to 0%<+/-3%
|
|
frequency
|
50 or 60Hz+/-0.5%
|
|
Convert time
|
Power outage or restoration with zero interruption, UPS to bypass, bypass to UPS power supply
|
|
Waveform distortion degree
|
Sine wave<2% (line load)
|
|
Peak ratio
|
3:1
|
|
一般特性
|
|
Battery backup time
|
10 or 15 minutes, adjustable as needed.
|
|
Full load efficiency (%)
|
90%
|
92%
|
93%
|
|
overload
|
150% 1 minute, 125% 10 minutes, 110% 30 minutes
|
|
Noise (dBA, distance 1 meter)
|
<55
|
<60
|
<65
|
|
ambient temperature
|
-5 ℃~+40 ℃ (no condensation)
|
|
maintenance bypass
|
Equipped with an automatic bypass and manual bypass switch, using a first in, then off, completely zero interruption protection
|
|
Warning system
|
Sound and light warning (can be equipped with UPS status Chinese voice warning system)
|
|
communication service
|
A 24-hour emergency automatic notification system can be installed to promptly handle and eliminate UPS abnormal states.
|
|
External dimensions and weight
|
|
Rated input KVA
|
10
|
15
|
22.5
|
30
|
40
|
50
|
60
|
80
|
90
|
100
|
125
|
150
|
160
|
200
|
250
|
300
|
400
|
|
Width (mm)
|
650
|
1300
|
1200
|
1800
|
2400
|
|
Weight (kg)
|
300
|
360
|
360
|
420
|
520
|
680
|
760
|
850
|
950
|
1050
|
1100
|
1200
|
1500
|
1700
|
1800
|
1850
|
1950
|
|
H×D(mm)
|
1540×700
|
1690×800
|
1900×800
|
|
|
Attention: Different voltages can be used to accommodate and increase standby time. According to the modified version, the external dimensions of Di can be different.
|
|
All technical changes shall be subject to the nameplate markings. Monitoring software needs to be purchased separately. The entire system can be equipped with a 12 phase rectifier.
|
|
|