Online flowmeter

NegotiableUpdate on 02/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Online flowmeter: $r $n excitation method $r $n three amplitude low-frequency rectangular wave excitation and high-frequency excitation
Product Details

Technical Specifications
Nominal Diameter
10,15,20,25,32,40,50,65,80,100,125,150,200,250,300,350,400,500…1800,2000
Nominal Pressure
0.6, 1.0, 1.6, 2.5, 4.0, 6.3
Process connection
Flange connection, flange standard: GB/9119-2010
structural form
Integrated (IP65); Split type (IP65 and IP68)
lining material
Polytetrafluoroethylene (PTFE) (≥ DN25 or above); Chloroprene rubber (≥ DN65 or above); F46; polyurethane
electrode material
Platinum, tantalum, Hastelloy, titanium, 316L, tungsten carbide
measuring tube
304 stainless steel
Shell flange
Carbon steel (standard); Stainless steel (non-standard customized)
fluid temperature
≤ 160° C
accuracy class
Level 0.5 (within the range of 0.3m/s to 10m/s); Repeatability 0.15%
Measurable flow velocity
0.1m/s—15m/s
Effective flow rate
0.3m/s -10m/s (accuracy level 0.5)
power supply
18-36VDC or 85-265VAC, power less than 8W
output
4—20mA, Frequency output 0-10KHZ, pulse equivalent; Network function (optional)
excitation method
Three amplitude low-frequency rectangular wave excitation and high-frequency excitation
excitation current
125mA/160mA
Dielectric conductivity
≥ 0.5μs/cm2
electrical interface
M20×1.5 1/2NPT
Protection level
IP65 (integrated, split type); IP68 (split type)
Grounding method
Grounding ring (user specified) or grounding electrode, pipeline grounding
display mode
Display screen resolution FSTN mode 128 × 64
Power off storage
The terminal electrical memory EEPROM ensures that the set parameters and accumulated flow data are not lost even after power failure