We use industrial online pH meters and pH controllers in our daily sewage treatment process. Here we introduce the installation method of industrial online pH meters, the range of 0-14Ph for industrial online pH meters, the display of 0 for industrial online pH meters, the use and maintenance of industrial online pH meters, calibration of industrial online pH meters, external calibration of industrial online pH plans, manufacturers of industrial online pH meters, ranking list of industrial online pH meters, and who is good at industrial online pH meters. We hope this can help everyone
The installation methods for industrial online pH meters include suspended installation, reactor installation, flange installation, and generally submerged installation.
The use, maintenance, and calibration of industrial online pH meters: Pay attention to the temperature and pressure of the medium when selecting the pH meter electrode probe. During daily use, keep the probe glass bulb clean and calibrate once a week (no more than one month) to ensure the accuracy of measurement results; The method for calibrating Yangjian manufacturer's online industrial pH meter is:
onlinepHCalculated byPHcalibration
PHThe calibration adopts the two-point calibration method, and the electrode is cleaned with distilled water before calibration,Then prepare the calibration buffer (do not use tap water to configure the calibration buffer, as it may not be calibrated)Or inaccurate calibration)And prepare distilled water for cleaning the electrodes during the calibration process. The calibration process is as follows:
1. Press the "SET" button to enter the settings menu, select "1. Electrode Calibration", press "SET" to enter the calibration menu, prompt to enter the pH value of the first calibration point solution, enter pH=6.86 as shown in the following figure:
Please enter the solutionPH1 |
|
06.86 pH |
After modifying the values, pressThe "SET" button displays the solution pH and measured signal, as shown in the following figure:
calibration point1 |
|
solutionPH : 6.86 pH measured value : 6 mV |
2. Place the cleaned electrode into a pH 6.86 standard solution, gently stir a few times, wait for the measured value on the second row of the instrument to stabilize, and then press "SET”Press the key to start calibration (you can also press it)Press the "ESC" key to cancel the calibration of this point.
After the first point calibration is completed, the instrument enters the second point calibration.
3. The instrument prompts to enter the pH value of the second point standard solution, which is pH=4.00 (if using a standard solution with pH 9.18, enter pH=9.18), as shown in the following figure:
Please enter the solutionPH2 |
|
04.00 pH |
After completing the numerical modification, pressThe "SET" button displays the solution pH and measured signal, as shown in the following figure:
calibration point2 |
|
solutionPH : 4.00 pH measured value : 170 mV |
4Remove the electrode from the standard buffer solutionPH=6.86Take it out and clean it thoroughly,And dry it with filter paper, then insert the electrode into the standard buffer solutionPH4.00(orpH9.18)Gently stir a few times, waitwaitinstrumentThe second linemeasured valuestable. Press“SET”Press the key to start calibration. (You can also press“ESC”Key to cancel calibration)
After both points are calibrated, the instrument displays the calibration result, as shown in the following figure:
Calibration completed 25.0℃ |
|
6.86 pH 6 mV 4.00 pH 170 mV |
The calibration result shown in the above figure indicates that the calibrated temperature isAt 25 ℃, the measured signal voltage of the electrode in the first point 6.86 pH standard solution is 6mV, and the measured signal voltage in the second point 4.00 pH standard solution is 170mV. Press the "ESC" button to exit.
Hangzhou Yangjian Automation Instrument Co., Ltd. mainly produces pH meters, turbidity meters, industrial online conductivity meters, industrial online dissolved oxygen meters, industrial online pH meters, online pH meters, ultrasonic level meters, dissolved oxygen detectors, level meters, etc. Welcome friends from all walks of life to negotiate.