Welcome Customer !

Membership

Help

Nadler Swiss Nadler Analytical Chemistry (China)
Custom manufacturer

Main Products:

instrumentb2b>Products

Nadler Swiss Nadler Analytical Chemistry (China)

  • E-mail

    18913684488@163.com

  • Phone

    18913684488

  • Address

    No. 137 Puzhu North Road, Pukou District, Nanjing

Contact Now

Online ammonia nitrogen potassium water quality sensor

NegotiableUpdate on 02/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Online ammonia nitrogen potassium water quality sensor: Immersion sensor is used to measure the dissolved ion concentration of open industrial water, sewage, etc. The sensor supports continuous monitoring and has a built-in temperature sensor. Compact design, easy installation, and reliable operation. A single sensor supports both analog and digital output. The built-in electrodes can be disassembled and maintained, supporting simultaneous measurement of three types of electrodes and mutual compensation between ions. The $r $n sensor is mainly used in industries such as urban sewage, municipal sewage, and chemical energy.
Product Details

Online ammonia nitrogen potassium water quality sensorStandard cable of 10 meters;

It is a multi parameter sensor specifically designed for online measurement of ammonia nitrogen and nitrate nitrogen. The sensor adopts the ion electrode method, so when measuring, users only need to insert the sensor into the water sample to directly read the values of ammonia nitrogen and nitrate nitrogen.

Online ammonia nitrogen potassium water quality sensorBuilt in pH compensation and temperature compensation;

1) Before using the sensor, please shake it vertically in the air to ensure that there is no air residue on the ion electrode head.

2) Sensors should be placed in larger containers for long-term testing. Before client testing, please soak the sensor in clean water and replace it with clean water 2-3 times to ensure that there is no potassium ion residue on the surface of the pH electrode.

3) When the sensor is in use or left out of water for more than 30 minutes, please place the sensor in the water sample and let it stand for more than 60 minutes. After the value stabilizes, read the value. Economically reliable:

-No sample pretreatment is required, and ammonia nitrogen and nitrate nitrogen can be measured directly.

-PH measurement is standard - no reagents required, low cost of use - flexible to use, with a wide range of applications:

-Wide range: 0.1-1000 mg/l NH4-N or 0.5-1000 mg/l NO3-N - Easy to operate and safe:

-Directly installed by the pool without the need for a liquid collector or sample transfer pump

-Replacing the laminated cap every 6 months effectively extends the service life of the electrode. Standardized digital communication is plug and play


1) After connecting the compensating ion electrode and setting the channel type, the compensation is automatically implemented by the system;

2)Concentration fluctuation(Non absolute value)It is a decisive factor;

3)Suggestion: Potassium ion concentration> 40 mg/lAnd in± 20 mg/lWhen there is fluctuation within the range, compensation electrodes need to be used. If there is no fluctuation, manual offset compensation can be performed; The concentration of potassium ions is equivalent to the concentration of ammonia nitrogen10For ammonia nitrogen analysis, it is recommended to use other methods.

4)Suggestion: Chloride ion concentration> 500 mg/lAnd in± 100 mg/lWhen there is fluctuation within the range, compensation electrodes need to be used. If there is no fluctuation, manual offset compensation can be performed;