Online H2S oxygen gas analyzer,The GPR-7500 1S transmitter and GPR-7500 A1S analyzer are used to measure ppm level sulfurized oxygen in gases. Both tools can be used in ATEX certified hazardous areas.
The analyzer (Zone 3 version) provides pressure compensation, alarm relays, and Modbus RTI communication modules
Online H2S oxygen gas analyzer,highlight
4-20mA output as standard
-2x on-site optional concentration alarm (AIS only)
Modbus communication module (AIS only)
Standard samples include sampling valves, hygrometers, and flow meters
Optional sampling system
Voltage 12-28V DC or ATEX certified power supply
The lifespan of sensors is generally 24 months
Online H2S oxygen gas analyzer,application
Measurement of Trace H and S in Natural Gas
| precision | Under constant conditions, the entire cutting range is less than 2% within 01 |
| Analysis Hall | a-20, 9-50, 0-100 tapping m, 3 types of full range, Automatically adjust the mouse program or fix it in a certain Lv and |
| certification | Certification allowed for use in hazardous areas* UL: United States: UL 1203, UL 913, UL 508 Canada: CAN/CSA C22.2 No. 3O-M1986, CAN/CSA C22.2 No. 157-92, CAN/CSA C22.2 No. 14-10 ATEX: Directive 94/9/EC |
| Application Integration | ATEX certification; EX II 2 G Ex d [lb] lb IIB T4 Child Calling+5 Politics |
| call the police | Dual user configurable alarm relay 3 A @ 100 V AC. On site programmable delayed alarm and calibration alarm bypass (IAS only) |
| School entrance | 50 z 100 ppm HZS's standard air balance air |
| compensation | Pressure compensation (AI5 standard) |
| 1/4” min; 3/8 "ventilation duct>3m | |
| control | Waterproof Sasa Pan, Confectionery Drive Range Selection, Proofreading, and Unified Service Trade Function |
| Easy to show | LCD 显示 7。 x 35mm; Resolution of 0.1 ppm; Display the real-time ambient temperature and pressure as |
| shell | Outdoor application NEMAType 3R |
| Maintain a steady flow rate of 0.2 Nl/min | |
| Fusion degree | 1% soil within the full range |
| pressure enter exit |
Adjust to. , 3~2 barg provides atmospheric pressure for a flow rate of 0.2NI/min |
| power supply | 12 ~ 26 V DC 110 ~ 220 V AC(C(AIS> |
| Response time | Achieve 90% of full range within 90 seconds |
| Take Xiang System | Condense the sensor with a filter, flow meter, and sample/kick sensor. Note: "The sensor needs to be exposed to air for cutting! Moisture can recover the eyelashes in 2 to 3 hours |
| Bin Yingdu | <0.5% within the full range |
| L ü fan Yao Hao | OSV-72-BH<Standard Yan Fan Country) |
| 24 months @+25 ° C and | |
| signal output | 4-20 mA Modbus RTU module (AIS only) |
| Operate Gongguo | -10~+45 hits |
| warranty | The analyzer and sensor burial are both 12 months old |
| Leng liquid is divided into | Non handle steel |
| Additional equipment | |
| The oxygen regulation system is connected to the Michell instrument | |