Industrial grade high temperature and humidity dew point meter humidity sensorThe HKT532 series temperature and humidity transmitter products are positioned as industrial grade products. For temperature and humidity measurement within the range of 0-100% RH and -100-200 ℃, utilize various high-precision probe resources from Swiss companies. The display accuracy is ± 0.8% RH, ± 0.1 ℃ (23 ℃, 0... 100%), with temperature compensation, and the analog output can be changed arbitrarily in 4-20mA. 3-line 12864 dot matrix intelligent "Chinese character menu", alarm status, thin film button zero point correction function, humidity sensor self-test and drift compensation.
Industrial grade high temperature and humidity dew point meter humidity sensorTechnical parameters“
| probe type | Metal Industrial probe |
|---|---|
| sensor | Hygromer HT-1 |
| temperature sensor | PT100 1/3 DIN Class B |
| long-term stability | <1% RH/year |
| measurement range | -100...200 °C (short-term peak load) / 0...100 %rh |
| Precision, standard precision mode | At 23 ° C/10, 35, 80% RH, ± 0.8% RH/± 0.1 ° C |
| Accuracy at 23 ± 5 ° C | ±0.8 %rh / ±0.1 °C |
| Response time t 63 | <15 sec. |
| size | HC2A-IM102-M: Ø15 x 86 mm x 2 m Cable; HC2A-IM302-M: Ø15 x 236 mm x 2 m Cable; HC2A-IM305-M: Ø15 x 236 mm x 5 m Cable |
| scope of work | -100…200 °C / 0…100 %rh |
| maximum wind speed | 3.5 m/s, without filter |
| computational load | Dew point or frost point |
| User defined analog output | have |
| Software Update | Through the Internet and HW4 software |
| User information | From HW4 (Device Management) |
| Output signal type | 2 x 0…1 VDC |
| Digital output signal (standard) | UART |
| Service interface | UART |
| FDA/GAMP compatibility | Compatible with FDA 21 CFR Part 11 and GAMP |
| Adjust the probe through software | 1 point&multiple points% rh&° C |
| Analog output signal (standard) | 0…1 V = 0…100 %rh; 0…1 V = -40…60 °C |
| Reverse voltage protection | mechanical connection |
| Maximum cable length | Passive cables can be up to 5m long, while active cables can be up to 100m long |
| Probe material | Stainless steel 1.4301 |
| Probe protection | Filter bracket, brass nickel plated |
| filter element | Order separately based on the application |
| power supply | 3.3…5 VDC |