- Phone
-
Address
B611, Fujun Building, 10-12 Dekang Road, Tongdewei, Baiyun District, Guangzhou City
Guangzhou Ruifeng Experimental Equipment Co., Ltd
B611, Fujun Building, 10-12 Dekang Road, Tongdewei, Baiyun District, Guangzhou City

F-950 portable three gas analyzer(detectableCO、CO₂TheC₂H₄Three types of gases,Mainly used for ethylene detection in fruits and vegetables
United StatesFelix F-950 Three Gas Analyzer Product Introduction:
Ethylene,CO2 and O2,To maintain good product quality at every stage of the supply chain.
The multifunctional design of F-950 allows it to adapt to many environments, from cold storage to shipping containers.
F-950 is easy to operate,Weight less than one kilogram,Measurement using electrochemical cellsEthylene between 0-200ppm.
F-950 is a choice for measuring ethylene production in various types of fruits.
United StatesFelix F-950 Three Gas Analyzer Product Features:
measurementC2H4, CO2, and O2
inDisplay results within 30 seconds
data storage
Handheld lightweight
Internal data recording and storage(4GBSD card)
Continuous battery lifeMore than 8 hours
Visualization reading in dark environment
PolarCept! TM water filter is used to remove non ethylene hydrocarbons
United StatesFelix F-950 Three Gas Analyzer Technical Parameters:
Sampling flow rate:70 milliliters per minute
sampling time:80 seconds
data saving:automatic,interval1 second
display:Sunlight visible translucent LCD
operating environment:0℃-50℃(0-90% humidity does not condense)
Working atmospheric pressure:500-1200mbar
Overall dimensions:18cm x 13.5cm x 5.5cm
weight:0.95 kilograms
Attachment:Aluminum powder coating
battery life:8.5 hours
Energy source:Detachable rechargeable lithium battery
PC interface:USB and WI-FI SD card+Bluetooth
data recording:ethylene,CO2 and O2 concentrations,date,time,RH,GPS location
model |
F-900 |
F-940 |
F-950 |
F-960 |
|
parameter |
Standard ethylene, optional CO2 and O2 |
EthyleneCO2、O2 |
EthyleneCO2、O2 |
EthyleneCO2、O2 |
|
purpose |
High precision ethylene measurement |
storage room |
Headspace gas |
Ripening room |
|
ethylene |
range |
0-200ppm、0-2.5ppm |
0-10ppm |
0-200ppm |
0-500ppm |
resolution |
0.1ppm、1ppb |
0.1ppm |
0.1ppm |
1ppm |
|
precision |
±5% |
±5% |
±5% |
±5% |
|
detection limit |
0.1ppm |
0.5ppm |
10ppm |
||
CO2 |
range |
0-2000ppm or 0-200% |
0-100 |
0-20% |
0-100 |
resolution |
0.1ppm or 0.01% |
0.1% |
0.01% |
0.1% |
|
precision |
± 2% or ± 1.5% |
±5% |
±1.5% |
±5% |
|
O2 |
range |
0-100 |
0-100 |
0-100 |
0-100 |
resolution |
0.1% |
0.1% |
0.1% |
0.1% |
|
precision |
±2% |
±5% |
±2% |
±5% |
|